background image

 

 

 

 

Siemens AG 

Digital Industries 

Postfach 48 48 

90026 NÜRNBERG 

GERMANY 

A5E50831253-AA 

 05/2021 Subject to change 

Copyright © Siemens AG 2021. 

All rights reserved 

Legal information 

Warning notice system 

This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent 

damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert 

symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are 

graded according to the degree of danger. 

 

DANGER 

indicates that death or severe personal injury 

will

 result if proper precautions are not taken. 

 

 

WARNING 

indicates that death or severe personal injury 

may

 result if proper precautions are not taken. 

 

 

CAUTION 

indicates that minor personal injury can result if proper precautions are not taken. 

 

 

NOTICE 

indicates that property damage can result if proper precautions are not taken. 

If more than one degree of danger is present, the warning notice representing the highest degree of danger will 

be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to 

property damage. 

Qualified Personnel 

The product/system described in this documentation may be operated only by 

personnel qualified

 for the specific 

task in accordance with the relevant documentation, in particular its warning notices and safety instructions. 

Qualified personnel are those who, based on their training and experience, are capable of identifying risks and 

avoiding potential hazards when working with these products/systems. 

Proper use of Siemens products 

Note the following: 

 

WARNING 

Siemens products may only be used for the applications described in the catalog and in the relevant technical 

documentation. If products and components from other manufacturers are used, these must be recommended 

or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and 

maintenance are required to ensure that the products operate safely and without any problems. The permissible 

ambient conditions must be complied with. The information in the relevant documentation must be observed. 

Trademarks 

All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication 

may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. 

Disclaimer of Liability 

We have reviewed the contents of this publication to ensure consistency with the hardware and software 

described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the 

information in this publication is reviewed regularly and any necessary corrections are included in subsequent 

editions. 

Содержание SIMATIC IOT2050

Страница 1: ... SIMATIC IOT2050 Starterkit Product Information 06 2021 A5E50831253 AA Package list 1 Preparing for installation 2 Mounting the device 3 Connecting the device 4 Installing the IOT2000 Input Output Module 5 Insert Micro SD card 6 ...

Страница 2: ...by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens product...

Страница 3: ... types 8 3 Mounting the device 10 3 1 Mounting instructions 10 3 2 Mounting on DIN rails 11 3 2 1 Secure the mounting clips 11 3 2 2 Mounting on DIN rails 13 3 3 Wall mounting 14 3 3 1 Vertical wall mounting 14 3 3 2 Horizontal wall mounting 15 4 Connecting the device 16 4 1 Notes on connecting 16 4 2 Connecting the function earth 17 4 3 Connecting the power supply 19 5 Installing the IOT2000 Inpu...

Страница 4: ...SIMATIC IOT2050 Starterkit 4 Product Information 06 2021 A5E50831253 AA Package list 1 ...

Страница 5: ...put Module and three plastic mounting clamps A5E50613788 1 SD card Inserted in IOT2050 8 GB 1 Power adapter AC DC Power supply 12 V 1 Network cable RJ45 cable 1 5 m 1 Accessory Kit Mounting bracket mounting clamps and screws 1 Quick Install Guide Printed paper 1 OSS Readme Printed paper 1 Important notes on your device Printed paper Note Additional information on the software topics commissioning ...

Страница 6: ...e to transport the unit again Note Damage to the device during transport and storage If a device is transported or stored without packaging shocks vibrations pressure and moisture may impact the unprotected unit A damaged packaging indicates that ambient conditions have already had a massive impact on the device The device might be damaged Do not dispose of the original packaging Pack the device d...

Страница 7: ... the device for immediate repair NOTICE Damage from condensation If the device is subjected to low temperatures or extreme fluctuations in temperature during transportation for example in cold weather moisture could build up on or inside the device condensation Moisture causes a short circuit in electrical circuits and damages the device In order to prevent damage to the device proceed as follows ...

Страница 8: ...airs or theft You can find this information on the rating plate The following illustration shows an example Example rating plate Enter the identification data in the table below Order number 6ES Serial number S V Production version FS All existing Ethernet ad dresses MAC 2 3 Permitted mounting positions and mounting types The device can be mounted horizontally or vertically on a DIN rail or to a w...

Страница 9: ... range for operation that depends on the mounting position Mounting type Ambient temperature for operation Rail mounting Vertical 0 to 50 C Horizontal 0 to 40 C Wall mounting Vertical 0 to 45 C Horizontal 0 to 40 C Clearances Ensure that the following clearances measurements to another component or to a wall of a housing are complied with Below the device 50 mm Above the device 50 mm ...

Страница 10: ...ps and brackets Fasten securely NOTICE Insufficient load carrying capacity If the mounting surface for wall mounting does not have an enough load bearing capacity the device may fall and be damaged Ensure that the mounting surface on the wall can bear four times the total weight of the device including fixing elements NOTICE Incorrect fixing elements If you use anchors and screws other than those ...

Страница 11: ... DIN rails 3 2 1 Secure the mounting clips Requirement The DIN rail is installed at the installation site 35 mm standard profile Mounting bracket and mounting clamps Two screws T8 screwdriver Secure the mounting clips for vertical mounting 1 Lay the rail clamp on the rear of the device 2 Fasten the rail clamp with the supplied screws ...

Страница 12: ...21 A5E50831253 AA Secure the mounting clips for horizontal mounting 1 Lay the rail clamp on the rear of the device 2 Fasten the rail clamp with the two supplied screws 3 Lay the brackets on the rear of the device Align the bracket edge with the device edge 4 Fasten the brackets with the supplied screws ...

Страница 13: ...rd profile rail at the position shown and push the device down 2 Swing the rail clamp of the device from below through the standard profile rail 3 Push the device in the direction of the standard profile rail You will hear the device click into place Vertical Horizontal Removing 1 Push down the device until it is released by the rail clamp 2 Swing the device out of the standard profile rail 3 Lift...

Страница 14: ...orizontal or vertical wall mounting Note The device must be installed on the plate of an enclosure Requirement Two mounting brackets Two screws T8 screwdriver Procedure for mounting 1 Lay the mounting brackets on the rear of the device 2 Fasten the brackets with supplied screws 3 Mark the bore holes drill the required holes in the wall and fasten the device to the wall using two screws ...

Страница 15: ...evice is suitable for horizontal or vertical wall mounting Requirement Two mounting brackets Two screws T8 screwdriver Procedure for mounting 1 Lay the mounting brackets on the rear of the device 2 Fasten the brackets with supplied screws 3 Mark the bore holes drill the required holes in the wall and fasten the device to the wall using two screws ...

Страница 16: ... to the device with terminals e g 24 VDC power supply cables to the 24 VDC power supply connectors Utiliser des câbles en cuivre sur les connexions à bornes Utilisez des câbles en cuivre Cu pour tous les câbles d alimentation qui sont raccordés à l appareil par des bornes par exemple les câbles d alimentation 24 V CC sur le connecteur d alimentation 24 V CC NOTICE Fault caused by I O devices The c...

Страница 17: ...errite magnet 4 2 Connecting the function earth A connected function earth discharges electrical charges from the metal enclosure The function earth also improves the discharge of interference generated by external power cables signal cables or cables for I O modules to ground The connection for the function earth is labeled with the following symbol WARNING Electric shock and risk of fire High vo...

Страница 18: ...ction earth with minimum cross section of 2 5 mm2 copper cable Procedure Clamp the cable lug on the function earth Firmly attach the cable lug to the function earth connection on the device using the M4 thread with the torque of 1 Nm see part labeled Connect the function earth to the protective conductor con nection of the cabinet or the plant in which the device is in stalled ...

Страница 19: ... IEC EN DIN EN UL 61010 1 Note The power supply must be adapted to the input data of the device If there are voltage peaks on power supply lines use a protective device in the form of a varistor MOV UMOV U rated x 1 2 BLITZDUCTOR BVT AVD 24 918 422 or compatible Requirement You are using the supplied terminal A slotted screwdriver with a 3 mm blade Procedure 1 Switch off the power supply 2 Connect...

Страница 20: ...re and electric shock The on off switch does not isolate the device from the power supply Risk of electric shock if the device is opened incorrectly or defective There is also a risk of fire if the device or connecting lines are damaged Death or serious bodily injury can result You should therefore protect the device as follows Always pull out the power plug when you are not using the device or if...

Страница 21: ...ontact pins of the module connect correctly with the terminal strips of the motherboard 1 Loosen the shield cover Carefully press with the blade of a flat blade screwdriver in the marked recesses and carefully pull on the appropriate place on the shield cover 2 Remove the shield cover 3 Insert the mounting clamp into the marked boreholes on the motherboard shown below Note Insert the marked side o...

Страница 22: ...the IOT2000 Input Output Module SIMATIC IOT2050 Starterkit 22 Product Information 06 2021 A5E50831253 AA 4 Install the Input Output module on the motherboard 5 Install the Input Output module cover to the IOT2050 ...

Страница 23: ...sing the Micro SD card in a device installed in a system you must observe the safety regulations for work on electrical systems Carefully insert the Micro SD card into the card holder without applying excess force 1 Open the card cover on the bottom 2 Push the Micro SD card correctly into the supporting frame The contacts of the Micro SD card must point in the direction of the motherboard 3 Push t...

Страница 24: ...nnecting the function earth 18 F function earth 17 Connecting 17 I Identification data 8 Installation on a DIN rail 8 M Micro SD card 23 Mounting Wall 1415 Mounting position 8 Mounting type 8 P Package contents 6 Checking 6 Packaging 6 Checking 6 Removing 6 Power supply Connecting 19 R Rating plate 8 S Safety instruction Storage 7 Transportation 7 W Wall mounting 81415 ...

Страница 25: ...Index SIMATIC IOT2050 Starterkit Product Information 06 2021 A5E50831253 AA 25 ...

Отзывы: