B-11
Equipment Manual OP7, OP17
Release 04/99
Remedy:
Cause
Mes-
sage
615
The line to be output is larger than the amount of
print memory reserved for it or the number of
control sequences is too great.
Check configuration as regards
logging.
616
Internal error
Incorrect data format in process link.
Correct the data format.
617
Internal error
Incorrect word length in process link.
Correct the word length.
618
Configuration error in actual control value (bit
number > 15).
Bit number for actual control varia-
ble must be < 15.
619
Error presetting setpoint (error in data structures).
Change configuration and retransfer.
620
Illegal keyboard ID: module number too high or
number of keys does not match keyboard ID.
Enter configuration to match hard-
ware.
621
Incorrect parameter transferred: message type
Set required value by way of stan-
dard screen or PLC.
622
Configured recipe does not fit in recipe mailbox
on PLC (> 512 data words).
Reduce configured size of recipe and
retransfer configuration.
623
Internal error
Screen object for “Send Recipe“ is not a recipe
type (fixed by COM TEXT).
If the fault is not corrected by perfor-
ming a restart, please contact the SI-
MATIC Hotline.
624
No recipe entries found.
Set up area pointers and retransfer
configuration.
625
Recipe number does not exist.
Reconfigure recipe.
626
No setpoints have been configured.
g
p
627
Internal error
Configured keyboard block number too high.
Correct the block number.
628
Recipe does not fit in mailboxes.
Increase configured size of recipe
mailbox or succeeding recipe mail-
box.
629
LED assignment area too small.
Increase size of LED assignment
area according to bit numbers used.
630
Keyboard assignment area too small.
Increase size of keyboard assignment
area according to bit numbers used.
631
Message configuration incomplete or incorrect.
Variable x:
1, 2
Alarm message triggered not configured
3
Process link only created symbolically.
4
Actual-value field only created symbolically.
5, 6
Event message triggered not configured
7
Symbolic actual-value field only created symbo-
lically.
21..24 Field texts for symbolic actual value do not exist
25
Illegal field type
8..20
Internal error
Complete configuration.
If the fault is not corrected by perfor-
ming a restart, please contact the SI-
MATIC Hotline.
Содержание simatic hmi op7
Страница 6: ...iv Equipment Manual OP7 OP17 Release 04 99 Preface ...
Страница 11: ...Product Description 1 Functionality 2 Part I Introduction ...
Страница 12: ...2 2 Equipment Manual OP7 OP17 Release 04 99 ...
Страница 22: ...1 10 Equipment Manual OP7 OP17 Release 04 99 ...
Страница 26: ...2 4 Equipment Manual OP7 OP17 Release 04 99 ...
Страница 28: ...2 6 Equipment Manual OP7 OP17 Release 04 99 ...
Страница 74: ...7 16 Equipment Manual OP7 OP17 Release 04 99 ...
Страница 90: ...9 6 Equipment Manual OP7 OP17 Release 04 99 ...
Страница 96: ...10 6 Equipment Manual OP7 OP17 Release 04 99 ...
Страница 98: ...10 8 Equipment Manual OP7 OP17 Release 04 99 ...
Страница 104: ...11 6 Equipment Manual OP7 OP17 Release 04 99 ...
Страница 109: ...Installation 14 Commissioning 15 Device Description 16 Part IV Commissioning and Description of Devices ...
Страница 110: ...13 4 Equipment Manual OP7 OP17 Release 04 99 ...
Страница 138: ...16 10 Equipment Manual OP7 OP17 Release 04 99 ...
Страница 140: ...P 12 Equipment Manual OP7 OP17 Release 04 99 ...
Страница 162: ...B 20 Equipment Manual OP7 OP17 Release 04 99 ...