No.
Action/response
KTP400 display
9. 1. Press "
Network interface” to open the
dialog for changing the network settings.
2. Make your choice between automatic IP
address assignment via "
DHCP” and
manual IP address assignment.
3. Touch the respective input fields and
enter the IP address and the subnet
mask with the screen keyboard, here:
IP address: 192.168.1.80
Subnet mask: 255.255.255.0
4. Under "
Ethernet parameters” in the
"
Mode and speed” selection field, tick
"
Auto Negotiation”; this automatically
detects and sets the connection type
and the transmission rate in the
PROFINET network.
5. Activate the "
LLDP” switch to enable the
operator panel to exchange information
with other operator panels. In this
example, "
LLDP” can be activated or
deactivated.
6. Under "
PROFINET” in the "Device
name” field, enter a network name for
your operator panel. The name must
meet the following requirements:
Max. four blocks with max. 63
characters each. Example:
"Press1.Fender.
Bodywork
.Hall3”
Characters from "
a” to "z”, numbers "0”
to "
9”; special characters: "-” and ".