Commissioning
7
7.1
Requirements for commissioning
NOTICE
Risk of damage to the device!
Make sufficient allowances for the device to acquire room temperature before you put it into
use. If condensation has developed on the device wait at least 12 hours before you switch it
on.
Note
The device features an off/off switch and an on/off button.
By default, the BIOS Setup entry "After Power Failure" is set to "Power On". This means that
the device is turned on using the on/off switch.
If the BIOS Setup entry is set to "Stay Off" or "Last state" and the on/off switch is set to "I"
(ON), the device can only be turned on by pressing the on/off button.
●
Connect the peripherals, such as the keyboard, mouse, monitor and the power supply,
before putting the device into operation.
●
The operating system you ordered for your device is already installed on the hard disk.
7.2
Switching on the device
Note
Commission the device before you install additional hardware, such as a PCI interface card.