![Siemens SIMATIC FM 353 Скачать руководство пользователя страница 315](http://html.mh-extra.com/html/siemens/simatic-fm-353/simatic-fm-353_manual_1265357315.webp)
Troubleshooting
11-13
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
11.3.2
Error messages
Overview
The errors are listed in Tables 11-6...11-8 according to error class.
Table 11-6
Operator errors
Cl.
No.
Error message,
error analysis and remedy
Mes-
sage/
Display
Operator errors
Error response: “Feed STOP” see Table 11-2
2 (02) 1 (01)
Operating mode not allowed
CBS
Cause
The operating mode selected is not allowed.
Effect
Elimination Select an allowed operating mode
2 (02) 4 (04)
Incorrect operating mode parameters
CBS
Cause
In the “Jogging” and “Control” operating modes, the speed or
frequency level selected is not 1 or 2. The setpoint number in
incremental operating mode is not allowed (1...100 and 254
allowed).
Effect
Elimination Set operating mode parameters to an allowable value.
2 (02) 5 (05)
Start enable missing
CBS
Cause
A travel command was given in the absence of a start enable
(start, external start, R+ / R
−
)
Effect
Elimination Restore travel command and wait for start enable
2 (02) 9 (09)
Axis is not synchronized
CBS
Cause
Synchronization of the axes is necessary in the “Incremental
relative”, “MDI” and “Automatic” operating modes.
Effect
Elimination Execute reference point approach
2 (02) 11 (0B) Direction specification not allowed
CBS
Cause
In operating modes “Jog”, “Control” or “Incremental relative”
the direction settings R+/R
−
are active at the same time. With
“Reference point operation” the direction setting no longer
agrees with the startup direction specified in the MD.
Effect
Elimination Per cause
Cl. = Detail event class, No. = Detail event number, CBS = checkback signals, DB = data block
Note:
Value (xx) = Hexadecimal notation of the error number
Содержание SIMATIC FM 353
Страница 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 26: ...Basic Principles of Positioning 2 4 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 148: ...Programming the Technological Functions 6 68 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...