This attribute specifies whether or not a filter can be displayed for each table column in the
"Parameters" tab of the properties dialog and in the SIMATIC BATCH OS Properties control.
Default: Yes, a filter row is displayed for all table columns.
The attribute can be dynamized with the ParametersListColumnFilterVisible name.
11.5.3.13
AllocationsListColumnWidth
String.
This attribute defines the width of the table columns in the "Allocations" tab of the properties
dialog and in the SIMATIC BATCH OS Properties control. The default values for column width
are as follows:
Table column
Column width in pixels
Recipe assignments
100
Unit
100
Class
150
Strategy
100
Process parameter
200
Start allocation
30
The values are entered, separated by a semicolon.
The attribute can be dynamized with the AllocationsListColumnWidth name.
11.5.3.14
AllocationsListColumnOrderAndVisibility
String.
This attribute defines the sequence of the table columns in the "Allocations" tab of the
properties dialog and in the SIMATIC BATCH OS Properties control. If values are not specified,
the corresponding columns are not displayed in the control.
The values are separated by a semicolon and entered in the following syntax: 1;2;3;4;5;6. By
changing the sequence of the values, you make a corresponding change in the column
sequence.
Default: 1;2;4;3;5;6.
The attribute can be dynamized with the AllocationsListColumnOrderAndVisibility name.
11.5.3.15
AllocationsListColumnResizeEnabled
Boolean variable.
This attribute specifies whether or not the column width in the "Allocations" tab of the properties
dialog and in the SIMATIC BATCH OS Properties control can be adapted. If yes is set, an
operator can adapt the column width in process mode.
Default: Yes, the column width can be changed.
The attribute can be dynamized with the AllocationsListColumnResizeEnabled name.
BATCH OS controls
11.5 Control properties references
SIMATIC BATCH V8.2
656
Operating Manual, 02/2016, A5E35958174-AA
Содержание SIMATIC BATCH
Страница 30: ...Security information SIMATIC BATCH V8 2 30 Operating Manual 02 2016 A5E35958174 AA ...
Страница 135: ...Example Engineering 7 1 Basic engineering for PCS 7 SIMATIC BATCH V8 2 Operating Manual 02 2016 A5E35958174 AA 135 ...
Страница 403: ...BATCH Control Center 9 8 Batch control SIMATIC BATCH V8 2 Operating Manual 02 2016 A5E35958174 AA 403 ...
Страница 584: ...BATCH Recipe Editor 10 5 Other functions SIMATIC BATCH V8 2 584 Operating Manual 02 2016 A5E35958174 AA ...
Страница 722: ...Appendix 13 4 Command line parameters for BatchCC SIMATIC BATCH V8 2 722 Operating Manual 02 2016 A5E35958174 AA ...
Страница 1158: ...Index SIMATIC BATCH V8 2 1158 Operating Manual 02 2016 A5E35958174 AA ...