As an alternative, you can use the BatchID attribute that should be preferred due to its
performance.
Default: None
The attribute can be dynamized with the OrderName name.
11.5.3.4
BatchName
String.
With this attribute, you specify which batch will be displayed in the control. Apart from the
BatchName attribute, the OrderName and OrderCategoryName attributes are also required to
identify the batch.
As an alternative, you can use the BatchID attribute that should be preferred due to its
performance.
Default: None
The attribute can be dynamized with the BatchName name.
11.5.3.5
BatchID
Long integer.
This attribute specifies which batch will be displayed in the control. The entry of a BATCH ID
has higher priority than the entry of the BatchName attribute.
Default: None
The attribute can be dynamized with the BatchID name.
11.5.3.6
TreeVisible
Boolean variable.
This attribute specifies whether or not the navigation area is displayed in the control. In the
navigation area, the recipe structure is shown in the form of folders and contents. The status
of batches is shown superimposed on the folder symbols. In process mode, the size of the
navigation area can be adapted by pressing and holding down the left mouse button.
Default: Yes.
The attribute can be dynamized with the TreeVisible name.
11.5.3.7
ToolbarOrderAndVisibility
String.
Specifies the sequence of the symbols in the OS control toolbar. If individual values are not
specified, the corresponding toolbar symbols are not displayed in the control. For certain
toolbar symbols to not be displayed, negative values are required.
The values are separated by a semicolon and entered in the following syntax: 1;2;3;...39.
Changing the sequence of the toolbar symbols in the toolbar would, for example, produce the
following values: 2;1;;3;...39. A double semicolon or the value 0 create a vertical line separator
BATCH OS controls
11.5 Control properties references
SIMATIC BATCH V8.2
Operating Manual, 02/2016, A5E35958174-AA
651
Содержание SIMATIC BATCH
Страница 30: ...Security information SIMATIC BATCH V8 2 30 Operating Manual 02 2016 A5E35958174 AA ...
Страница 135: ...Example Engineering 7 1 Basic engineering for PCS 7 SIMATIC BATCH V8 2 Operating Manual 02 2016 A5E35958174 AA 135 ...
Страница 403: ...BATCH Control Center 9 8 Batch control SIMATIC BATCH V8 2 Operating Manual 02 2016 A5E35958174 AA 403 ...
Страница 584: ...BATCH Recipe Editor 10 5 Other functions SIMATIC BATCH V8 2 584 Operating Manual 02 2016 A5E35958174 AA ...
Страница 722: ...Appendix 13 4 Command line parameters for BatchCC SIMATIC BATCH V8 2 722 Operating Manual 02 2016 A5E35958174 AA ...
Страница 1158: ...Index SIMATIC BATCH V8 2 1158 Operating Manual 02 2016 A5E35958174 AA ...