background image

 

Starting up the device 

 

3.3 Setting up Microsoft Windows operating system 

Panel PC 870 V2 
QuickStart, Edition 03/2004, A5E00299738 

3-3

 

3.3 

Setting up Microsoft Windows operating system 

Introduction 

Immediately following the start up of the computer unit, the setup assistant will start, which is 

used to setup the parameters of the operating system.  

 

Note 
The dialogs of the setup assistants differ slightly in some places in the Windows 98 SE, 

Windows NT 4.0, Windows 2000 and Windows XP operating systems. 
In order to change to the next dialog, click on the "Continue" button. In order to change the 

entry in the previous dialog, click on the "return" button. 

Procedure 

1.  For Windows 98 and Windows NT 4.0 only: If required, enter the Microsoft Windows 

Product Key which you wrote down in the identification data. 

2.  Accept the Microsoft licensing agreement. 
3.  For Windows 2000 and Windows XP only: Perform the regional settings of the operating 

system. 

4.  Enter the company names and user names. 
5.  Enter the administrator password where necessary. 
6.  When connecting a computer unit to a network only: Enter the name of the computers for 

identification. 

7.  When the dialog "SetDisplay" appears only: Click on the button with the screen size and 

screen resolution which matches your device. 

8.  Restarting the operating system: 

– 

Windows 98: Exit the operating system session and restart the computer unit. 

– 

Windows NT 4.0: Click on the "Finish" button. 

– 

Windows 2000 and Windows XP: automatic restart. 

The operating system will be restarted. The system settings will be updated and the desktop 

will be set up. The setup of the operating system is complete. 

Содержание SIMATIC 870 V2

Страница 1: ... Unpacking and connecting the device 2 Starting up the device 3 Technical specifications 4 SIMATIC PC Panel PC 870 V2 QuickStart Edition 03 2004 This manual applies to devices with the order numbers 6AV774 and 6AV775 ...

Страница 2: ...mmission to earth and to tag circuits equipment and systems in accordance with established safety practices and standards Intended Use Please note the following Warning This device and its components may only be used for the applications described in the catalog or technical description and only in connection with devices or components from other manufacturers approved or recommended by Siemens Th...

Страница 3: ...he PS 2 mouse 2 6 2 6 Connect the PS 2 keyboard 2 6 2 7 Description decentralized design 2 7 2 8 Connecting a decentralized design 2 7 2 9 Connecting the computer unit control unit connecting cable 2 8 3 Starting up the device 3 1 3 1 Overview 3 1 3 2 Turn on device 3 2 3 3 Setting up Microsoft Windows operating system 3 3 3 4 Installing applications and drivers 3 4 4 Technical specifications 4 1 ...

Страница 4: ...Panel PC 870 V2 QuickStart Edition 03 2004 A5E00299738 ...

Страница 5: ...s for the Panel PC 670 870 V2 Operator Unit Refered to as operating instructions for the operator unit in the following File Panel_PC_870_V2_re_e pdf Operating instructions for the Panel PC 670 870 V2 Computer Unit Refered to as operating instructions for the computer unit in the following The CD ROM drive is only available once the device has been switched on This is why the first steps for commi...

Страница 6: ...Panel PC 870 V2 QuickStart Edition 03 2004 A5E00299738 ...

Страница 7: ...ause unintentional operating situations under some circumstances For more details consult the technical data in the EMC Requirements chapter Handling and disposal of lithium batteries Warning Danger of explosion and the release of harmful substances Do not throw lithium batteries into fire do not solder onto the cell body do not open do not short circuit do not reverse pole do not heat above 100 C...

Страница 8: ...e contents for completeness and any visible transport damage Check for completeness using the enclosed Contents of Delivery list 7 Notify the delivery service in charge immediately if the packages contents are incomplete or damaged Warning Make sure that a damaged unit is not installed nor put into operation 2 3 Make note of identification data Procedure 1 Write down the Microsoft Windows Product ...

Страница 9: ...n the rating label on the edge of the side of the control unit Figure 2 2 Rating label of the control unit example 4 Write down the ethernet address of the device The ethernet address is located in the main menu of the BIOS setup Hardware Options Ethernet Address Identification Number 1 Microsoft Windows Product Key 2 SVP number 3 Order number of the computer unit 4 Power supply version 5 Approbat...

Страница 10: ...socket 2 PROFIBUS MPI DP MPI interface RS485 isolated potential optional 9 pin d Sub socket 3 ETHERNET RJ 45 Ethernet connection 10 100 Mbps 4 USB 2 0 USB connector Right USB port 1 left USB port 2 5 COM2 Serial port 1 V 24 9 pin d Sub socket 6 KEYBOARD Connection for a PS 2 keyboard 7 MOUSE Connection for a PS 2 mouse 8 LPT1 Parallel interface 25 pin 9 DVI VGA DVI VGA connection for CRT or LCD mo...

Страница 11: ...for TFT displays up to 1024 x 768 pixels 2 I O interface for connecting front panel components 3 Access to the interfaces on operator panels closed by a screwed metal cover during shipment of Box PC 4 Mounting screw for the steel sheet cover AC power supply Position of the IEC power connector Description IEC power connector for the AC power supply to the device The maximum permitted power range is...

Страница 12: ...y to the device 1 24 V DC 2 0 V DC 3 Protective conductor 2 5 Connect the PS 2 mouse Procedure 1 Insert the cable of the external PS 2 mouse or another external input device or pointing device into the PS 2 mouse socket 2 6 Connect the PS 2 keyboard Procedure 1 Insert the cable of a PS 2 keyboard of your choice into the PS 2 keyboard socket Notice Use a keyboard with a straight keyboard plug to le...

Страница 13: ...ralized design overview 2 8 Connecting a decentralized design Principle In the decentralized design the control unit and computer unit are in separate locations Components The following illustration shows as an example of a 15 control unit on which a mounting plate is attached to the back side The remote module also called receiver and the optional direct key module are attached to the mounting pl...

Страница 14: ...nnect the control unit and the computer unit with the connecting cable which is illustrated in the Options section Warning Avoid contact with network lines and data transmission lines during thunderstorms and do not disconnect any lines during this time For complete isolation from the power supply always pull out the power plug Procedure 1 Plug the jack plug of the connection cable into the connec...

Страница 15: ...en transporting the device at low temperatures prevent condensation from forming on or in the device The same applies when the device is subjected to extreme changes in temperature Wait 12 hours before switching the device on Before starting up the device allow it to adjust slowly to room temperature Do not subject it directly to heat radiation from a heating device however I O modules Connect the...

Страница 16: ...er unit 3 Lock the power plug in place For Panel PC 670 only clamp the supplied ferrite core onto the power supply cable This step can also be performed later For additional information please refer to the chapter Connecting in the computer unit operating instructions 4 Plug the power supply cable of the computer unit into a socket with a grounded protective conductor 5 If your computer has a powe...

Страница 17: ...ired enter the Microsoft Windows Product Key which you wrote down in the identification data 2 Accept the Microsoft licensing agreement 3 For Windows 2000 and Windows XP only Perform the regional settings of the operating system 4 Enter the company names and user names 5 Enter the administrator password where necessary 6 When connecting a computer unit to a network only Enter the name of the compu...

Страница 18: ...and applications can be installed Note The dialogs overlap themselves In order to change from one dialog to another press the key combination Alt Tab Procedure 1 Change to the SetDisplay dialog The dialog will appear here only if it did not appear during the setup of the operating system 2 Click on the button with the screen size and screen resolution which matches your device Figure 3 1 Setdispla...

Страница 19: ...the device will be updated 5 Change to the Digital signature dialog 6 For Windows 2000 and Windows XP only Click on the Yes button for every digital signature Figure 3 3 Digital signature 7 Decentralized design only Enter the path to the USB keyboard controller driver C drivers USB Keyboard controller The touchware driver and USB keyboard controller driver will be installed ...

Страница 20: ...rted the Touch screen calibration dialog will appear Carry out the following steps carefully Figure 3 4 Touch screen calibration 9 Click on the Calibrate button The dialog for touch calibration will appear 10 Touch the cross hairs on the touch screen for at least 3 seconds and no longer than 10 seconds The Calibration complete dialog will appear Exit the calibration by clicking on the Done button ...

Страница 21: ...2004 A5E00299738 3 7 Raid system Applies only to the raid system option The application Raid promise monitor will appear after every restart of the computer unit For additional information please refer to the chapter Functions in the computer unit operating instructions Figure 3 5 Raid promise monitor ...

Страница 22: ...Panel PC 870 V2 QuickStart Edition 03 2004 A5E00299738 ...

Страница 23: ...er consumption AC at 230 W secondary 360 W efficiency approx 65 Max power consumption DC at 180 W secondary 265 W primary efficiency approx 70 3 Max current output AC 5 V 25 A 3 3 V 10 A 155 W total allowed 12 V 12 2 A Peak 14 0A 12 V 0 8 A 5 V 0 5 A Limited to 0 8 A 5 Vaux 2 A Peak 2 5 A The total voltage amounts to max 230W max current output DC 5 V 22 A 3 3 V 16 A 140 W total allowed 12 V 4 4 A...

Страница 24: ...IEC 60068 2 1 IEC 60068 2 2 IEC 60068 2 14 In operation 5 C to 45 C Storage transport 20 C to 60 C Gradient max 10 C h in operation 20 C h storage no condensation Relative humidity tested to IEC 60068 2 78 IEC 60068 2 30 in operation 5 to 80 at 25 C no condensation Storage transport 5 to 95 at 25 C no condensation Mech Ambient conditions Vibration Operation 1 2 Storage transport tested to DIN IEC ...

Страница 25: ...in D sub connector LPT1 Parallel port standard EPP mode Connection for printer with parallel port DVI Port for external CRT LCD monitor Keyboard PS 2 keyboard connection Mouse PS 2 mouse connection USB 2 0 2 x external at the interface side PROFIBUS MPI interface potential isolated Transmission rate Operating mode Physical interface Memory address area Interrupts 9 pin d sub socket 9 6 Kbps to 12 ...

Страница 26: ...C 60068 2 2 IEC 60068 2 14 Rel humidity limit values during operation during storage transport 5 85 at 25 C 5 95 at 25 C 77 F Tested according to IEC 60068 2 3 IEC 60068 2 30 IEC 60068 2 56 Temperature change Maximum 10 K h Condensation not permissible Supply air No corrosive gases 4 3 Options Components The options comprise the following components Options Order No Direct key module 6AV7671 7DA00...

Страница 27: ...necting cable and do not undo the connecting cable Otherwise the HF properties of the connecting cable will become irreversibly altered Perfect functioning is then no longer guaranteed Male connector for connecting to computing unit Female connector for connecting to operating unit Figure 4 1 Cable for connecting control unit and computer unit Features Cable connector at the computer unit Cable co...

Страница 28: ...Panel PC 870 V2 QuickStart Edition 03 2004 A5E00299738 ...

Отзывы: