Position and assignment
/'&9
/
0
/'&9
/
0
Figure 6-1
Position of the power supply, for example on the SCALANCE XP208
Connector
Pin number
Contact
Assignment
L1 24 V DC
1
L1+
24 V DC
2
Do not connect
-
3
M1
Ground
4
Do not connect
-
L2 24 V DC
1
L2+
24 V DC
2
Do not connect
-
3
M2
Ground
4
Do not connect
-
Connecting/disconnecting the power supply
NOTICE
Turn off the power supply before you insert or remove the plug of the power supply.
1. Connect the plug and socket. Make sure that they lock in place correctly.
2. Tighten the knurled screw (torque 1 Nm).
M12 Power T-Tap
To connect several devices to a power supply so that they are cascading, you can use an M12
Power T-Tap, see the section "Product overview (Page 17)".
The M12 Power T-Tap has two M12 sockets and one M12 plug.
Note
The M12 Power T-Tap has not been released for PoE power supply.