Technical specifications
7.5 Technical specifications of the SCALANCE XC216
SCALANCE XC-200
68
Operating Instructions, 07/2016, C79000-G8976-C442-01
Technical specifications
Installation options
•
Wall mounting
•
Installation on a DIN rail
•
Mounting on an S7-300 standard rail
•
Mounting on an S7-1500 standard rail
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C)
> 48 years
Switching properties
Aging time
45 seconds
Max. number of learnable MAC
addresses
2048
Response to LLDP frames
Blocking
Response to spanning tree BPDU
frames
Forwarding
CoS acc. to IEEE 802.1Q
Yes
QoS priority queues
4
1)
Note the wiring rules (Page 49).