3.7
NFC
3.7.1
The "show" commands
This section describes commands with which you display various settings.
Note
You will find further information on NFC in the operating instructions "SCALANCE XC-200".
3.7.1.1
show nfc active status
Description
This command shows whether or not the NFC function (Near Field Communication) is activated
or deactivated.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
or
cli#
Syntax
Call the command without parameters:
show nfc active status
Result
The status of the NFC function is displayed.
3.7.2
Commands in the global configuration mode
This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
configure terminal
command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can be
found in the relevant sections.
You exit the Global configuration mode with the
end
or
exit
command and are then in the
Privileged EXEC mode again.
Configuration
3.7 NFC
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
123