The SCALANCEXB004-2 group includes the following devices:
• SCALANCE XB004-2
• SCALANCE XB004-2LD
The SCALANCE XB005 group includes the following devices:
• SCALANCE XB005
• SCALANCE XB005G
The SCALANCE XB008 group includes the following devices:
• SCALANCE XB008
• SCALANCE XB008G
SCALANCE XB004-1
There are two TP port groups:
Group1: P1 and P4
Group2: P2 and P5
Between ports of different port groups, an insulation voltage of 1.5 kV is adhered to
(corresponds to IEEE802.3, Chapter 33.4.1.1, Environment B), e.g. between P1 and P2.
The requirements for Environment A are met between ports of the same group, e.g. between P1
and P4.
SCALANCE XB004-2
There are two TP port groups:
Group1: P2 and P5
Group2: P3 and P6
Between ports of different port groups, an insulation voltage of 1.5 kV is adhered to
(corresponds to IEEE802.3, Chapter 33.4.1.1, Environment B), e.g. between P2 and P3.
The requirements for Environment A are met between ports of the same group, e.g. between P2
and P5.
SCALANCE XB005
There are three TP port groups:
Group1: P1 and P4
Group2: P2 and P5
Group3: P3
Between ports of different port groups, an insulation voltage of 1.5 kV is adhered to
(corresponds to IEEE802.3, Chapter 33.4.1.1, Environment B), e.g. between P1 and P2.
The requirements for Environment A are met between ports of the same group, e.g. between P2
and P5.
Description of the device
4.4 TP ports (twisted pair)
SCALANCE XB-000
Operating Instructions, 01/2022, A2B00077300-11
29
Содержание SCALANCE XB-000
Страница 10: ...Safety notices SCALANCE XB 000 10 Operating Instructions 01 2022 A2B00077300 11 ...
Страница 36: ...Description of the device 4 6 LEDs SCALANCE XB 000 36 Operating Instructions 01 2022 A2B00077300 11 ...
Страница 54: ...Connecting up 6 6 IE FC RJ 45 Plug 180 SCALANCE XB 000 54 Operating Instructions 01 2022 A2B00077300 11 ...
Страница 98: ...Approvals SCALANCE XB 000 98 Operating Instructions 01 2022 A2B00077300 11 ...
Страница 102: ...Index SCALANCE XB 000 102 Operating Instructions 01 2022 A2B00077300 11 ...