3.3.2

Coupling of two PRP networks via an HSR ring

+65

353

353

6&$/$1&(

;51$

6&$/$1&(

;51$

6&$/$1&(

;51$

6&$/$1&(

;51$

6&$/$1&(

;51$

6&$/$1&(

;51$

6&$/$1&(

;51$

6,0$7,&6

&351$

3&

6,0$7,&6

3&

/$1$

/$1%

/$1$

/$1%

Figure 3-5

Topology of a coupling of two PRP networks via an HSR ring

Settings in WBM

You specify the functionality of the devices SCALANCE X204RNA 

 to 

 relating to the 

coupling of the two PRP networks on the WBM page X200 > Coupling Configuration. You need 

to configure the following parameters:
● Coupling Mode
● NetID

Configuration of the "Coupling Mode" parameter

Setting for device 

 and 

Redundant HSR PRP coupling, LAN A (The port P2/B is open and must not be used.)

Network topologies and redundancy
3.3 HSR-PRP coupling

SCALANCE X-200RNA

26

Operating Instructions, 10/2016, C79000-G8976-C342-04

Содержание SCALANCE X-200RNA

Страница 1: ... Introduction 1 Safety notices 2 Network topologies and redundancy 3 Descriptions of the products 4 Installation 5 Connecting up 6 Functional description and configuration using Web Based Management 7 Approvals and marking 8 Technical specifications 9 Accessories and compatible devices 10 Dimension drawings 11 ...

Страница 2: ... those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufacturers are used th...

Страница 3: ...ANCE X204RNA EEC 37 4 5 1 Product characteristics 37 4 5 1 1 SCALANCE X204RNA EEC PRP product characteristics 37 4 5 1 2 SCALANCE X204RNA EEC PRP HSR product characteristics 38 4 5 1 3 SCALANCE X204RNA EEC HSR product characteristics 39 4 5 2 SCALANCE X204RNA EEC TP interfaces 40 4 5 3 SCALANCE X204RNA EEC SFP interface 42 4 6 C PLUG 44 4 7 SELECT SET button 46 4 8 LEDs 49 4 8 1 SCALANCE X 200RNA ...

Страница 4: ...ion 82 7 7 2 System Identification Maintenance 83 7 7 3 System Restart Defaults 84 7 7 4 System Save Load 86 7 7 5 System Version Numbers 88 7 7 6 System Passwords 89 7 7 7 System SELECT SET button 90 7 7 8 System Event Log Table 92 7 7 9 C PLUG Information 93 7 8 The X200 menu 95 7 8 1 X200 Status 95 7 8 2 PRP configuration 97 7 8 3 HSR Coupling Configuration 98 7 8 4 Fault Mask 99 7 9 The Agent ...

Страница 5: ...Statistics menu 127 7 10 6 Packet Size Statistic 127 7 10 7 Packet Type Statistic 129 7 10 8 Packet Error Statistic 132 7 10 9 PRP Statistic 134 7 10 10 Redundancy Statistic 135 8 Approvals and marking 137 9 Technical specifications 143 10 Accessories and compatible devices 147 10 1 Accessories 147 10 2 PRP compatible devices 149 11 Dimension drawings 153 Index 157 Table of contents SCALANCE X 200...

Страница 6: ...Table of contents SCALANCE X 200RNA 6 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 7: ...tionality You can also implement the transition between a PRP and an HSR network with the SCALANCE X 200RNA Purpose of the Operating Instructions These Operating Instructions support you when commissioning networks with the IE switches of the SCALANCE X200RNA product line Validity of the Operating Instructions These Operating Instructions are valid for the following IE switches of the SCALANCE X 2...

Страница 8: ...A PRP SCALANCE X204RNA HSR SCALANCE X204RNA EEC SCALANCE X204RNA EEC PRP SCALANCE X204RNA EEC HSR SCALANCE X204RNA EEC PRP HSR Note SCALANCE X204RNA EEC PRP HSR This device can be configured either as a PRP device or as an HSR device If you configure the device as a PRP device it behaves in exactly the same way as the SCALANCE X204RNA EEC PRP If you configure the device as an HSR device it behaves...

Страница 9: ...ontents but also the following sections in the Appendix Index Audience These Operating Instructions are intended for persons commissioning Ethernet networks with the Parallel Redundancy Protocol PRP and or High availability Seamless Redundancy Protocol HSR Standards and approvals The devices of the SCALANCE X 200RNA product line meet the requirements for the CE mark For more detailed information r...

Страница 10: ...nes and networks In order to protect plants systems machines and networks against cyber threats it is necessary to implement and continuously maintain a holistic state of the art industrial security concept Siemens products and solutions only form one element of such a concept Customer is responsible to prevent unauthorized access to its plants systems machines and networks Systems machines and co...

Страница 11: ...ry Open Source Information Trademarks The following and possibly other names not identified by the registered trademark sign are registered trademarks of Siemens AG SIMATIC NET SCALANCE C PLUG OLM SIMATIC NET glossary Explanations of many of the specialist terms used in this documentation can be found in the SIMATIC NET glossary You will find the SIMATIC NET glossary on the Internet at the followi...

Страница 12: ...Introduction SCALANCE X 200RNA 12 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 13: ... with NEC Class 2 as described by the National Electrical Code r ANSI NFPA 70 If the equipment is connected to a redundant power supply two separate power supplies both must meet these requirements WARNING Maximum current The maximum current via the terminals is 10 A You should therefore include a fuse that trips at a current higher than 10 A The fuse must meet the following requirements Suitable ...

Страница 14: ...CE X204RNA only WARNING Requirements for the cabinet enclosure To comply with EC Directive 94 9 ATEX95 this enclosure must meet the requirements of at least IP54 in compliance with EN 60529 WARNING Suitable cables for temperatures in excess of 70 C If the cable or conduit entry point exceeds 70 C or the branching point of conductors exceeds 80 C special precautions must be taken If the equipment i...

Страница 15: ...e with UL CSA certification they are an open type To fulfill requirements for safe operation with regard to mechanical stability flame retardation stability and shock hazard protection the following alternative types of installation are specified Installation in a suitable cabinet Installation in a suitable enclosure Installation in a suitably equipped enclosed control room Safety notices SCALANCE...

Страница 16: ...Safety notices SCALANCE X 200RNA 16 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 17: ...it uses parallel separate networks made up of standard network components The end devices that use this method are connected to the two networks via a preceding device or via two integrated device interfaces This means that the frame of the end device can be transferred at the same time via both networks If a transmission path is interrupted the frame arrives at its destination via the second path...

Страница 18: ...y Protocol With the Parallel Redundancy Protocol PRP each node must transmit Ethernet frames on two independent parallel networks These are two physically separate networks with a bus linear star or ring topology The PRP destination device must also be connected to the two networks This then receives each frame twice The first frame is forwarded to the application Network topologies and redundancy...

Страница 19: ...ge 149 There are already end devices equipped with two Ethernet interfaces that are capable of handling the Parallel Redundancy Protocol Double Attached Nodes PRP DANP On the other hand there are many end devices starting with S7 controllers right through to control computers that communicate using TCP IP but do not support PRP and some even have only one Ethernet Interface With all these devices ...

Страница 20: ... two networks via a preceding device or via two integrated device interfaces This means that the frame of the end device can be transferred at the same time in both directions of the ring If a transmission path is interrupted the frame arrives its destination via the other path The devices of the SCALANCE X 200RNA product line are used to connect end devices without integrated HSR interfaces to HS...

Страница 21: ...This achieves N 1 redundancy without reconfiguration bumpless switchover There are already end devices equipped with two Ethernet interfaces that are capable of using the High availability Seamless Redundancy Protocol Double Attached Nodes HSR DANH On the other hand there are many end devices starting with S7 controllers right through to control computers that communicate using TCP IP but do not s...

Страница 22: ...ct line allow a link with a PRP network This coupling is in redundant form as described in standard IEC62439 3 Two SCALANCE X 200RNA devices are required One device is connected with the PRP network LAN A the other with LAN B Network topologies and redundancy 3 2 HSR SCALANCE X 200RNA 22 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 23: ...g with a PRP network can also take place non redundantly In this case only one SCALANCE X 200RNA device is required The device is connected to the PRP network LAN A and to LAN B Note This type of linking is not recommended because if the transition point fails the communication between HSR and PRP nodes is interrupted Network topologies and redundancy 3 2 HSR SCALANCE X 200RNA Operating Instructio...

Страница 24: ... 6 1 5 0 6 1 5 0 6 1 51 6 1 51 6 1 51 6 1 51 6 1 51 6 1 51 6 1 51 6 1 51 6 0 7 6 6 0 7 6 3 3 Figure 3 4 Topology of a coupling of two HSR rings via a PRP network Network topologies and redundancy 3 3 HSR PRP coupling SCALANCE X 200RNA 24 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 25: ...t P2 B is open and must not be used Setting for device and Redundant HSR PRP coupling LAN B The port P1 A is open and must not be used Configuration of the NetID parameter The network ID of the PRP network is specified with this parameter The valid range of values is 1 to 6 The SCALANCE X204RNA devices between the two rings belong to the same PRP network therefore you need to set the same NetID fo...

Страница 26: ... the devices SCALANCE X204RNA to relating to the coupling of the two PRP networks on the WBM page X200 Coupling Configuration You need to configure the following parameters Coupling Mode NetID Configuration of the Coupling Mode parameter Setting for device and Redundant HSR PRP coupling LAN A The port P2 B is open and must not be used Network topologies and redundancy 3 3 HSR PRP coupling SCALANCE...

Страница 27: ...P network and you therefore need to set the same value for the NetID parameter for both devices The same applies to the devices SCALANCE X204RNA and The last devices named belong however to a different PRP network and for this reason a different NetID from the devices and must be used For example NetID 5 could be assigned for devices und and NetID 6 for devices and Network topologies and redundanc...

Страница 28: ...Network topologies and redundancy 3 3 HSR PRP coupling SCALANCE X 200RNA 28 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 29: ...o 70 C up to 85 C max 16h Diagnostics LED 24 VDC 24 250 VDC 100 240 VAC Housing Plastic Metal Coated printed circuit boards as of hardware version 3 2 x 24 VDC 100 Base T full duplex 100 Base T half duplex 10 Base T SFP interface for SFP modules for HSR ports 100 Base FX for HSR ports using optional SFP modules Signaling contact on site operation SE LECT SET button Diagnostics via Web Based Manage...

Страница 30: ...0 Fiber single mode duplex LC 2 x SFP modules SFP991 1LD monomode glass up to 26 km 6GK5991 1AF00 8AA0 Fiber single mode duplex LC 2 x SFP modules SFP991 1LH monomode glass up to 70 km 6GK5991 1AE00 8AA0 Standard Ethernet ports PRP ports P1 A P2 B P1 A P2 B HSR ports HSR 1 HSR 2 HSR 1 HSR 2 Note TP connectors of SCALANCE X204RNA EEC The SCALANCE X204RNA EEC has 2 RJ 45 ports to which you can conne...

Страница 31: ...the parts for transport damage Recycling and disposal The products are low in pollutants can be recycled and meet the requirements of the WEEE directive 2012 19 EU for the disposal of electrical and electronic equipment Do not dispose of the products at public disposal sites For environmentally friendly recycling and the disposal of your old device contact a certified disposal company for electron...

Страница 32: ...ALANCE X204RNA EEC The following components are supplied with the SCALANCE X204RNA EEC SCALANCE X204RNA EEC device 3 pin plug in terminal block signaling contact 3 pin plug in terminal block power supply Safety notices CD Operating Instructions Primary Setup Tool Bracket for guiding the cable mechanical protection Note SFP modules are not supplied with the device Descriptions of the products 4 3 C...

Страница 33: ...A PRP has two RJ 45 jacks for connection of end devices or network segments without PRP capability P1 and P2 and two RJ 45 jacks for connecting to PRP networks LAN A and LAN B PRP A and PRP B Figure 4 1 SCALANCE X204RNA PRP Descriptions of the products 4 4 SCALANCE X204RNA SCALANCE X 200RNA Operating Instructions 10 2016 C79000 G8976 C342 04 33 ...

Страница 34: ...of end devices or network segments without HSR capability P1 A and P2 B and two RJ 45 jacks for connecting to the High availability Seamless Redundancy Protocol ring HSR 1 and HSR 2 Figure 4 2 SCALANCE X204RNA HSR Descriptions of the products 4 4 SCALANCE X204RNA SCALANCE X 200RNA 34 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 35: ...in 4 n c Pin 3 TD Pin 2 RD Pin 1 RD Note TP cords or TP XP cords with a maximum length of 10 m can be connected to the RJ 45 TP port With the IE FC cables and IE FC RJ 45 plug 180 an overall cable length of up to 100 m is permitted between two devices depending on the cable type Note The interfaces of the SCALANCE X204RNA meet the requirements for environment B according to IEEE 802 3 section 33 4...

Страница 36: ... play device that does not require settings to be made for commissioning MDI MDI X autocrossover function The advantage of the MDI MDI X autocrossover function is that straight through cables can be used throughout and crossover Ethernet cables are unnecessary This prevents malfunctions resulting from mismatching send and receive wires This makes installation much easier for the user The SCALANCE ...

Страница 37: ... The SFP modules can be used as an alternative to the two RJ 45 jacks PRP A and PRP B and are intended for the connection of the LAN A and LAN B networks End devices or network segments without PRP capability are connected to the RJ 45 jacks P1 and P2 Figure 4 4 SCALANCE X204RNA EEC PRP Descriptions of the products 4 5 SCALANCE X204RNA EEC SCALANCE X 200RNA Operating Instructions 10 2016 C79000 G8...

Страница 38: ...45 jacks A H1 and B H2 and are intended to connect networks LAN A and LAN B or to connect to the High availability Seamless Redundancy Protocol ring End devices or network segments without PRP or HSR capability are connected to the RJ 45 jacks 1 1 B and 2 2 B Figure 4 5 SCALANCE X204RNA EEC PRP HSR Descriptions of the products 4 5 SCALANCE X204RNA EEC SCALANCE X 200RNA 38 Operating Instructions 10...

Страница 39: ... jacks HSR 1 and HSR 2 and are intended for connection to the High availability Seamless Redundancy Protocol ring Standard Ethernet end devices or network segments that do not support HSR or networks to be linked are connected to the RJ 45 jacks P1 A and P2 B Figure 4 6 SCALANCE X204RNA EEC HSR Descriptions of the products 4 5 SCALANCE X204RNA EEC SCALANCE X 200RNA Operating Instructions 10 2016 C...

Страница 40: ... c Pin 3 TD Pin 2 RD Pin 1 RD Note TP cords or TP XP cords with a maximum length of 10 m can be connected to the RJ 45 TP port With the IE FC cables and IE FC RJ 45 plug 180 an overall cable length of up to 100 m is permitted between two devices depending on the cable type Note The interfaces of the SCALANCE X204RNA EEC PRP and HSR and PRP HSR meet the requirements for environment B according to I...

Страница 41: ...PRP and HSR is a plug and play device that does not require settings to be made for commissioning MDI MDIX autocrossover function The advantage of the MDI MDIX autocrossover function is that straight through cables can be used throughout and crossover Ethernet cables are unnecessary This prevents malfunctions resulting from mismatching send and receive wires This makes installation much easier for...

Страница 42: ...electrical interface RJ45 are not supported Table 4 5 SFP transceiver overview SFP transceiver SFP991 1 SFP991 1LD SFP991 1LH Transmission medium Wavelength Core diameter Outer diameter Multimode FO cable 1310 nm 50 or 62 5 µm 125 µm Monomode FO cable 1310 nm 9 µm 125 µm Monomode FO cable 1310 nm 9 µm 125 µm Maximum range 3 km 26 km 70 km Order number 6GK5991 1AD00 8AA0 6GK5991 1AF00 8AA0 6GK5991 ...

Страница 43: ... technique The transmission mode for 100Base FX is specified in the IEEE 802 3 standard Descriptions of the products 4 5 SCALANCE X204RNA EEC SCALANCE X 200RNA Operating Instructions 10 2016 C79000 G8976 C342 04 43 ...

Страница 44: ...mple replacement of the basic device If a device needs to be replaced the C PLUG is simply taken from the failed component and inserted in the replacement device The first time it is started up the replacement device has the same configuration as the failed device except for the MAC address set by the vendor Compatible devices As a general rule the data on the C PLUG is only compatible with device...

Страница 45: ...204RNA EEC on the top of the device See SELECT SET button Page 46 Follow the steps below to insert the C PLUG 1 Turn off the power to the device 2 Remove the protective cover 3 Insert the C PLUG in the intended compartment 4 Close the protective cover Note The C PLUG may only be inserted or removed when the power is off Removing the C PLUG Follow the steps below to remove the C PLUG 1 Turn off the...

Страница 46: ... button Figure 4 8 The five button phases Time the button is pressed in seconds Table 4 6 Button phases Phase Description 1 The currently set fault mask is displayed If no fault mask has been set all ports flash one after the other If you release the SELECT SET button in phase 1 this has no effect 2 The LEDs of the ports at which there is currently a link flash at 2 5 Hz If you release the SELECT ...

Страница 47: ...he mode LED returns to flashing mode SELECT SET button can be released without setting a mode If you have accidentally programmed the wrong mode e g by releasing at the switchover moment you can trigger a factory reset after the normal startup with the normal SELECT SET button functionality press for 10 seconds and reverse the programming Position of the SELECT SET button and C PLUG Note On the SC...

Страница 48: ... PLUG SELECT SET button Figure 4 9 Position of the C PLUG and SELECT SET button Descriptions of the products 4 7 SELECT SET button SCALANCE X 200RNA 48 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 49: ...dant power supplies 3 C PLUG error 4 Device startup the LED is lit for approx 20 seconds 5 Internal error 6 A redundancy error was detected 7 No problem has been detected by the SCALANCE X 200RNA PRP 4 8 1 2 Power LED The LEDs signal the following statuses of the SCALANCE X 200RNA PRP The status of the power supply is indicated by a green LED Device type SCALANCE LED lit green LED lit yellow LED n...

Страница 50: ...ds 4 Setting or display of the fault mask 4 8 1 4 LED displays during startup When the SCALANCE X 200RNA PRP starts up the following LED displays light up in the order shown 1 Power LEDs green light up immediately after turning on the power 2 Port LEDs go off the red error LED is lit for approx 10 seconds 3 Following startup the correct link status is indicated by the port LEDs after approximately...

Страница 51: ... red a SCALANCE X 200RNA HSR has detected an error fault At the same time the signaling contact opens assuming that the response of the signaling contact has not been configured differently The LED signals that the SCALANCE X 200RNA HSR can adopt the following statuses Device type SCALANCE LED lit red LED lit yellow LED not lit X204RNA HSR 1 2 3 4 5 6 7 8 X204RNA EEC HSR 1 3 4 5 6 7 8 X204RNA EEC ...

Страница 52: ...Ds Device type SCALANCE LED lit green LED lit yellow LED flashes yel low Number of LEDs X204RNA HSR 2 port LEDs 1 2 3 4 2 PRP port LEDs 1 2 3 4 X204RNA EEC HSR 2 port LEDs 1 2 3 4 2 PRP port LEDs 1 2 3 4 X204RNA EEC PRP HSR If configured as HSR device 2 port LEDs 1 2 3 4 2 PRP port LEDs 1 2 3 4 1 TP link exists no data reception 2 TP link data received at TP port 3 Device startup the LED is lit fo...

Страница 53: ...ts housing in other words that of the SCALANCE X204RNA EEC PRP and the SCALANCE X204RNA EEC HSR Depending on how you configure the SCALANCE X204RNA EEC PRP HSR the labeling is valid as described in the sections above The exception is the mode LED third LED from the top When the LED is lit the SCALANCE X204RNA EEC PRP HSR is in HSR mode This means that the right hand labeling of the LED displays ap...

Страница 54: ...Descriptions of the products 4 8 LEDs SCALANCE X 200RNA 54 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 55: ... prevents premature aging of the device and cabling WARNING Location for mounting a SCALANCE X204RNA EEC If a SCALANCE X204RNA EEC is operated at ambient temperatures between 60 C and 70 C the housing temperature may exceed 70 C When installing the X204RNA EEC select a location where only qualified service personnel or trained users have access to it Operation of the SCALANCE X204RNA EEC at ambien...

Страница 56: ...be maintained to neighboring devices or the wall of the housing By keeping to the minimum clearances there is then an adequate stream of air for heat dissipation during operation Keep to the following minimum clearances to neighboring devices Table 5 1 Minimum clearances when installing in cabinets Minimum clearance to devices below the SCALANCE X 200RNA 100 mm Minimum clearance to devices above t...

Страница 57: ...Press the device down against the DIN rail until it locks into place 3 Fit the connectors for the power supply 4 Fit the connectors for the signaling contact 5 Insert the terminal blocks into the sockets on the device Figure 5 1 Mounting on a 35 mm DIN rail based on the example of a SCALANCE X204RNA EEC Installation 5 2 Mounting on DIN rails SCALANCE X 200RNA Operating Instructions 10 2016 C79000 ...

Страница 58: ...o rail at top Lock in position below Secure with the screw Figure 5 2 Mounting the protective bracket on the SCALANCE X204RNA EEC Installation 5 2 Mounting on DIN rails SCALANCE X 200RNA 58 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 59: ... DIN rail catch on the bottom of the device using a screwdriver 3 Then pull the lower part of the device away from the DIN rail Figure 5 3 Removing from a 35 mm DIN rail based on the example of the SCALANCE X204RNA Installation 5 2 Mounting on DIN rails SCALANCE X 200RNA Operating Instructions 10 2016 C79000 G8976 C342 04 59 ...

Страница 60: ...Connect the electrical cable connecting cables 3 Fit the connectors for the signaling contact 4 Insert the terminal blocks into the sockets on the SCALANCE X204RNA 5 Screw the device to the wall Note The wall mounting must be capable of supporting at least four times the weight of the SCALANCE X204RNA see Technical specifications Page 143 Wall mounting of a SCALANCE X204RNA EEC To mount the device...

Страница 61: ...piece of DIN rail 35 mm to the wall 2 Now mount the SCALANCE X 204RNA on the DIN rail as described in the section DIN rail mounting See also Mounting on DIN rails Page 57 Dimension drawings Page 153 Installation 5 3 Wall mounting SCALANCE X 200RNA Operating Instructions 10 2016 C79000 G8976 C342 04 61 ...

Страница 62: ...Installation 5 3 Wall mounting SCALANCE X 200RNA 62 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 63: ...for the power supply match in their coding The plug and socket for the signaling contact are coded differently from the connection of the power supply The plugs for power supply and signaling contact cannot therefore be interchanged You can use non coded plugs in coded sockets and coded plugs in non coded sockets Pin assignment Pin number Pin assignment of the SCALANCE X204RNA PRP and HSR Pin assi...

Страница 64: ...ower supplies both must meet these requirements The signaling contact can be subjected to a maximum load of 100 mA safety extra low voltage SELV 24 VDC Never operate the SCALANCE X204RNA PRP and HSR with AC voltage or DC voltage higher than 28 8 V DC 24 VDC power supply NOTICE If the SCALANCE X204RNA is supplied over long 24 V power supply lines or networks measures are necessary to prevent interf...

Страница 65: ...ith a 100 to 240 VAC or 24 to 250 VDC power supply are not approved for use in hazardous areas according to EC RL 94 9 ATEX NOTICE Securing cables with dangerous voltage Make sure that the connector cannot be released accidentally by pulling on the connecting cable Lay the cables in cable ducts or cable channels and secure the cables where necessary with cable ties Protective ground WARNING PE con...

Страница 66: ...nt of the SCALANCE X 204RNA Pin assignment of the SCALANCE X 204RNA EEC Pin 1 F1 NO contact NC contact if a fault occurs F1 NC contact NO contact if a fault occurs Coding of the plug Pin 2 F2 F2 Pole terminal Coding of the socket Pin 3 F3 NO contact NC contact if a fault occurs Coding of the plug The following errors faults can be signaled by the signaling contact The failure of a link at a monito...

Страница 67: ...rrelates with the red fault LED Exception The absence of the power supply is signaled only by the signaling contact no display by the fault LEDs Note During startup the signaling contract is always active signals error fault Connecting up 6 2 Signaling contact SCALANCE X 200RNA Operating Instructions 10 2016 C79000 G8976 C342 04 67 ...

Страница 68: ...FP transceiver The SFP modules are supplied with power via the SFP slot of the SCALANCE X204RNA EEC Connecting up 6 3 SFP transceiver SCALANCE X 200RNA 68 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 69: ...il There is also a grounding bolt on the underside of the housing Connect the grounding bolt of the device to the nearest grounding point using the grounding cable To do this use the same wire cross section as the power supply cable however not smaller than 1 5 mm 16 AWG Connecting up 6 4 Grounding SCALANCE X 200RNA Operating Instructions 10 2016 C79000 G8976 C342 04 69 ...

Страница 70: ...Connecting up 6 4 Grounding SCALANCE X 200RNA 70 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 71: ...ction to the device is necessary Note To prevent unauthorized access to the SCALANCE X200RNA there is an automatic logout after 15 minutes or after the time configured in the Agent Timeout Configuration menu A manual logout is also possible with the appropriate button in the user interface Exiting the browser does not close the session If the browser is started again within the timeout the session...

Страница 72: ...Web Based Management see section Assignment of an IP address Page 74 To use Web Based Management there must be an Ethernet connection between the SCALANCE X 200RNA and the client computer Use of a Microsoft Internet Explorer version 8 or higher is recommended All the pages of Web Based Management require JavaScript You should therefore make sure that Java Script is enabled in your browser settings...

Страница 73: ...ad access to the configuration data of the SCALANCE X 200RNA 3 Enter your password in the Password input box If you have not yet set a password the default passwords as shipped apply Enter admin if you selected admin as the user name or user if you selected user Note For security reasons make sure that you change the original factory set passwords 4 Click the Log On button to start the logon Note ...

Страница 74: ...C 1518 and RFC 1519 An IP address consists of 4 bytes Each byte is represented in decimal with a dot separating it from the previous one This results in the following structure where XXX stands for a number between 0 and 255 XXX XXX XXX XXX The IP address is made up of two parts the network ID and the host ID This allows different subnets to be created Depending on the bytes of the IP address used...

Страница 75: ...subnet mask the ones must be set left justified there must be no zeros between the ones 7 3 2 Initial assignment of an IP address Configuration options An initial IP address for an IE switch cannot be assigned using Web Based Management or the Command Line Interface because these configuration tools require that an IP address already exists The following options are available to assign an IP addre...

Страница 76: ...l area network and this responds to the DHCP request of the IE switch the IP address subnet mask and gateway are assigned automatically when the module first starts up Functional description and configuration using Web Based Management 7 3 Assignment of an IP address SCALANCE X 200RNA 76 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 77: ...art buttons The device is then restarted and is in the selected operating mode Figure 7 2 Initializing the SCALANCE X204RNA EEC PRP HSR using WBM Initializing with CLI You can also initialize the SCALANCE X204RNA EEC PRP HSR using the CLI command setmode PRP HSR Go to top of menu tree Go up in menu tree Show menus commands exit Exit from CLI TELNET session restart Shutdown and startup again setmod...

Страница 78: ...ter you have initialized the SCALANCE X204RNA PRP HSR and restarted the device the corresponding dialog box is displayed in WBM Figure 7 3 SCALANCE X204RNA EEC PRP HSR in PRP mode Figure 7 4 SCALANCE X204RNA EEC PRP HSR in HSR mode Functional description and configuration using Web Based Management 7 4 Initializing the SCALANCE X204RNA EEC PRP HSR SCALANCE X 200RNA 78 Operating Instructions 10 201...

Страница 79: ...herefore displays simulated LEDs The top quarter of the screen shows a schematic representation of the SCALANCE X 200RNA with the corresponding LEDs The meaning of the LED displays is described in the section LEDs Page 49 in these Operating Instructions Figure 7 5 LED simulation of the SCALANCE X204RNA EEC Functional description and configuration using Web Based Management 7 5 LED simulation of th...

Страница 80: ...6 LED simulation of the SCALANCE X204RNA Functional description and configuration using Web Based Management 7 5 LED simulation of the WBM SCALANCE X 200RNA 80 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 81: ...link you log out from the device Updating the display with Refresh Web Based Management pages have a Refresh button at the lower edge of the page Click this button to request up to date information from the IE switch for the current page Storing entries with Set Values Pages in which you can make configuration settings have a Set Values button at the lower edge Click this button to save the config...

Страница 82: ...1 time frame or SNTP You can also see when and how it was set m The setting was made manually p The setting was made by the Simple Network Time Protocol SNTP System Up Time read only The time since the last restart Device Type read only The type designation of the device Device Description read only The type description of the device Functional description and configuration using Web Based Managem...

Страница 83: ... Identification Maintenance The following dialog box contains information on device specific vendor and maintenance data such as the order number serial number version numbers Figure 7 8 System Identification Maintenance I M 0 Here you can see the individual parameters for Identification Maintenance Functional description and configuration using Web Based Management 7 7 The System menu SCALANCE X ...

Страница 84: ...rting the SCALANCE X 200RNA as well as an option for resetting the settings of the SCALANCE X 200RNA Figure 7 9 System Restart and Defaults Functional description and configuration using Web Based Management 7 7 The System menu SCALANCE X 200RNA 84 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 85: ...ed Restart System Click the Restart System button to restart the SCALANCE X 200RNA You are prompted to confirm the restart in a separate dialog box During a restart the SCALANCE X 200RNA is reinitialized the internal firmware is reloaded and the device runs a self test The learned entries in the address table are deleted You can leave the browser window open while the SCALANCE X 200RNA restarts Re...

Страница 86: ...uitable files on your client PC Note Following a firmware update delete the cache of the Web browser Figure 7 10 System Save Load via HTTP Configuration File Name and directory path of the configuration file you want to load on the SCALANCE X 200RNA Firmware File Name and directory path of the file from which you want to load the new firmware Functional description and configuration using Web Base...

Страница 87: ...no longer possible This means that after downloading the firmware and restarting the device the IP address needs to be assigned again with the Primary Setup Tool and the required parameters set again Note If newer firmware and a newer FPGA version required on the device it is advisable to download the FPGA and then the firmware following the restart How to save data using HTTP 1 Start the save fun...

Страница 88: ... is being operated Figure 7 11 System Version Numbers Hardware The version of the firmware is shown here The hardware version product version is stored permanently on the SCALANCE X 200RNA FPGA Version The FPGA version is shown here Firmware The version of the firmware running on the SCALANCE X 200RNA Functional description and configuration using Web Based Management 7 7 The System menu SCALANCE ...

Страница 89: ...rds when supplied Admin password admin User password user In this dialog box if you are the administrator you can change the passwords for Admin and User The password can be up to a maximum of 16 characters 7 bit ASCII long Figure 7 12 System Passwords Functional description and configuration using Web Based Management 7 7 The System menu SCALANCE X 200RNA Operating Instructions 10 2016 C79000 G89...

Страница 90: ...isplay mode Reset to the factory defaults Define the dialog box and the LED display You will find a detailed description of the individual functions available with the button in the section SELECT SET button Page 46 Functional description and configuration using Web Based Management 7 7 The System menu SCALANCE X 200RNA 90 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 91: ... Fault Mask Figure 7 13 Select Set button configuration Enable Select Set Functions You can enable or disable the individual functions of the button by selecting or deselecting the relevant check box You apply your settings with Set Values Functional description and configuration using Web Based Management 7 7 The System menu SCALANCE X 200RNA Operating Instructions 10 2016 C79000 G8976 C342 04 91...

Страница 92: ...fy which events are logged in the Agent Event Configuration menu item Figure 7 14 System Event Log Table Sys Up Time This column shows the time since the SCALANCE X 200RNA was last restarted in the format HH MM SS Refresh Click this button to refresh the display Clear With this button you can delete the content of the log table Functional description and configuration using Web Based Management 7 ...

Страница 93: ...ration data stored on it Figure 7 15 C PLUG Information C PLUG State read only The status of the C PLUG C PLUG Device Group read only The module to which the C PLUG belongs C PLUG Device Type read only The device type of the C PLUG Configuration Revision readonly Configuration version of the C PLUG Functional description and configuration using Web Based Management 7 7 The System menu SCALANCE X 2...

Страница 94: ...rmation line of the C PLUG Modify C PLUG Modification of the configuration stored on the C PLUG Copying the current configuration on the C PLUG with associated restart Copying the factory configuration to the C PLUG with associated restart Deleting the configuration stored on the C PLUG Functional description and configuration using Web Based Management 7 7 The System menu SCALANCE X 200RNA 94 Ope...

Страница 95: ...s if you click the X200 folder icon The dialog box shows information about the power supply and the error status Figure 7 16 X200 Status Functional description and configuration using Web Based Management 7 8 The X200 menu SCALANCE X 200RNA Operating Instructions 10 2016 C79000 G8976 C342 04 95 ...

Страница 96: ...examples of possible error messages If more than one problem has occurred they are listed in the text box one above the other Error messages Meaning Redundant power line down The redundant power supply has failed Link down on monitored port The connection to a monitored port is interrupted No Fault The SCALANCE X 200RNA has not detected a fault the signaling contact has not responded and the fault...

Страница 97: ... By setting the check mark for Limitation Enabled the data throughput from the interlinks to the PRP ports is limited to the set value The limitation can be specified with Max Throughput A limitation between 50 and 80 is possible If the load on the interlinks is greater than the value set frames are discarded This occurs regardless of Ethertypes and any VLAN priorities Functional description and c...

Страница 98: ... Redundant HSR PRP coupling Setting with non redundant HSR PRP coupling P1 A is connected with LAN A P2 B with LAN B of a PRP network Redundant HSR PRP coupling LAN A Setting with redundant HSR PRP coupling P1 A is con nected with LAN A of a PRP network P2 B is open and may not be used Redundant HSR PRP coupling LAN B Setting with redundant HSR PRP coupling P1 B is con nected with LAN B of a PRP n...

Страница 99: ...rror states to be monitored by the SCALANCE X 200RNA and that will trigger the signaling contact Possible fault error states are the absence of the power supply power supply too low or an interrupted connection or an unexpected connection established to a partner device If the signaling contact is triggered this causes the fault LED on the device to light up and depending on the configuration of t...

Страница 100: ...e two power supplies of the SCALANCE X204RNA line 1 and line 2 is monitored A fault is then indicated by the message system when there is no power on one of the monitored lines line 1 or line 2 or when the voltage is too low less than 14 V Note This dialog box is not displayed with the SCALANCE X204RNA EEC because it does not have a redundant power supply Functional description and configuration u...

Страница 101: ...his port because for example the cable is not plugged in or the connected device is turned off An error fault can be signaled in the following ways depending on the configuration of the SCALANCE X 200RNA Signaling contact fault LED SNMP trap entry in the log table and the syslog Functional description and configuration using Web Based Management 7 8 The X200 menu SCALANCE X 200RNA Operating Instru...

Страница 102: ...lid link at this port because for example the cable should not be plugged in An error fault can be signaled in the following ways depending on the configuration of the SCALANCE X 200RNA Signaling contact fault LED SNMP trap entry in the log table and the syslog Functional description and configuration using Web Based Management 7 8 The X200 menu SCALANCE X 200RNA 102 Operating Instructions 10 2016...

Страница 103: ...x provides you with options for the IP address You can specify whether a SCALANCE X 200RNA obtains the IP address dynamically or you can assign a fixed address Figure 7 22 Agent Configuration Functional description and configuration using Web Based Management 7 9 The Agent menu SCALANCE X 200RNA Operating Instructions 10 2016 C79000 G8976 C342 04 103 ...

Страница 104: ...ol BOOTP Here you specify whether the IP address can be obtained using the Bootstrap Protocol DCP If you select this option the device can be accessed and configured using DCP PST Tool and STEP 7 DCP Read Only If you select this option the configuration data can only be read via DCP Primary Setup Tool and STEP 7 Agent IP Configuration IP Address Enter the IP address of the SCALANCE X 200RNA here S...

Страница 105: ...is dialog box you can send a PING to another device in the network to check whether it can be reached Figure 7 23 Ping IP Address Enter the IP address of the target device here Repeat Here enter how often the ping should be sent Ping If you click the Ping button you start the ping Functional description and configuration using Web Based Management 7 9 The Agent menu SCALANCE X 200RNA Operating Ins...

Страница 106: ...mmunity string A community string contains information about the user name and password in a string Different community strings are defined for read and write permissions More complex and more secure authentications are possible only in some SNMPv2 variants and in SNMPv3 Note To preserve security you should not use the default values public or private Configuration of SNMP with a SCALANCE X 200RNA...

Страница 107: ...ith SNMPv1 v2c Read Community String Here you enter the read community string maximum of 63 characters for the SNMP protocol Read Write Community String Here you enter the write community string maximum of 63 characters for the SNMP protocol Traps This enables disables the sending of SNMPv1 v2c traps Functional description and configuration using Web Based Management 7 9 The Agent menu SCALANCE X ...

Страница 108: ...ation Page 114 Note Traps are sent only when the Traps option was selected in SNMP Configuration Figure 7 25 SNMPv1 Trap Configuration IP Address Here you enter the IP addresses of the stations to which a SCALANCE X 200RNA will send traps Enable Trap Click on the check box next to the IP addresses to enable the sending of traps to the corresponding stations Functional description and configuration...

Страница 109: ...ss rights of these groups can also be found in the table Figure 7 26 SNMPv3 Groups By clicking the New Entry button or clicking on an entry the SNMPv3 Group Configuration dialog box is displayed Functional description and configuration using Web Based Management 7 9 The Agent menu SCALANCE X 200RNA Operating Instructions 10 2016 C79000 G8976 C342 04 109 ...

Страница 110: ...s By clicking the Set Values button you create a group according to the parameters set above Current Entries By clicking the Current Entries button you exit the SNMPv3 Group Configuration dialog box and return to the SNMPv3 Groups dialog box Functional description and configuration using Web Based Management 7 9 The Agent menu SCALANCE X 200RNA 110 Operating Instructions 10 2016 C79000 G8976 C342 ...

Страница 111: ... which the user belongs and the security level of the user in the table Figure 7 28 SNMPv3 Users By clicking the New Entry button or clicking on an entry the SNMPv3 Users Configuration dialog box is displayed Functional description and configuration using Web Based Management 7 9 The Agent menu SCALANCE X 200RNA Operating Instructions 10 2016 C79000 G8976 C342 04 111 ...

Страница 112: ...es button you create a user according to the parameters set above Current Entries By clicking the Current Entries button you exit the SNMPv3 Users Configuration dialog box and return to the SNMPv3 Users dialog box Functional description and configuration using Web Based Management 7 9 The Agent menu SCALANCE X 200RNA 112 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 113: ... Here you specify the WBM timeout Permitted values for the WBM timeout 0 3600 seconds 0 means There is no automatic logout CLI TELNET SSH Serial sec Here you specify the CLI timeout Permitted values for the CLI timeout 60 600 seconds Functional description and configuration using Web Based Management 7 9 The Agent menu SCALANCE X 200RNA Operating Instructions 10 2016 C79000 G8976 C342 04 113 ...

Страница 114: ...oxes you specify which events trigger which reactions on the SCALANCE X 200RNA The following options are available The SCALANCE X 200RNA sends an e mail with the error message The SCALANCE X 200RNA triggers an SNMP trap Functional description and configuration using Web Based Management 7 9 The Agent menu SCALANCE X 200RNA 114 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 115: ...200RNA writes an entry to the Syslog server Figure 7 31 Agent Event Configuration with the SCALANCE X204RNA EEC Functional description and configuration using Web Based Management 7 9 The Agent menu SCALANCE X 200RNA Operating Instructions 10 2016 C79000 G8976 C342 04 115 ...

Страница 116: ...ng handled again via a port that had previously failed Authentication Failure There was an SNMP access with a bad password or inadequate access rights Power Error SCALANCE X204RNA only This event occurs only when power supply line 1 and line 2 are monitored It indicates that there was a change to line 1 or line 2 Functional description and configuration using Web Based Management 7 9 The Agent men...

Страница 117: ...rror is reset if the difference in PRP frames received in LAN A and B remains almost the same If a PRP B frame is received at PRP A or vice versa the error is set until no more incorrect frames are received for approximately 30 seconds 7 9 9 Agent E Mail Configuration Setting the e mail client Here you can set the recipient sender and the SMTP server Figure 7 33 Agent E Mail Configuration Function...

Страница 118: ... server From Field Here enter the e mail address of the sender 7 9 10 Agent Syslog Configuration Setting the Syslog server Here you can specify the address of the Syslog server Figure 7 34 Agent Syslog Configuration Functional description and configuration using Web Based Management 7 9 The Agent menu SCALANCE X 200RNA 118 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 119: ...figuration Setting the DHCP mode There are several ways of identifying the SCALANCE X 200RNA in the configuration of the DHCP server with the MAC address with a freely defined client ID Functional description and configuration using Web Based Management 7 9 The Agent menu SCALANCE X 200RNA Operating Instructions 10 2016 C79000 G8976 C342 04 119 ...

Страница 120: ...selected and the text disabled is displayed DHCP Client ID For the DHCP mode via Client ID you can assign an identification string here that is assigned to a SCALANCE X 200RNA and will be evaluated by the DHCP server Functional description and configuration using Web Based Management 7 9 The Agent menu SCALANCE X 200RNA 120 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 121: ...If no time of day synchronization was possible the box displays Date time not set You can also set the date and time manually the required input format is MM DD YYYY HH MM SS In this case the text box displays the data and time along with the suffix m If the system time was set as a result of synchronization with a server the suffix is p Time Synchronization This box is read only and shows when th...

Страница 122: ...ways sends UTC time This time is then recalculated and displayed as the local time based on the time zone There is no standard daylight saving time switchover on the SCALANCE X 200RNA Init Poll Interval Here you can enter the interval at which a SCALANCE X 200RNA repeats the poll when the system time is initially set if this was not successful the first time Poll Interval Once the system time has ...

Страница 123: ... aging Display of statistical data 7 10 2 Switch Config Switch functionality The Switch Configuration dialog box appears if you click the Switch folder icon In this dialog box you specify the aging time of the SCALANCE X 200RNA Figure 7 37 Switch Configuration Functional description and configuration using Web Based Management 7 10 The Switch menu SCALANCE X 200RNA Operating Instructions 10 2016 C...

Страница 124: ...different switch port If the check box is not enabled a SCALANCE X 200RNA does not delete learnt addresses automatically Aging Time sec Here you enter the time after which the SCALANCE X 200RNA deletes an address if it has not received frames with the corresponding sender address Here the aging time can be set as required within the range from 1 to 655 seconds 7 10 3 Port status Overview of the co...

Страница 125: ...an enabled port Note With the SCALANCE X 200RNA the ports cannot be turned off Link Shows the connection status to the network The available options are as follows Up The port has a valid link to the network a link integrity signal is being received Down The link is down for example because the connected device is turned off 7 10 4 Switch Forwarding Database The Switch Forwarding Database dialog b...

Страница 126: ...with the learnt destination MAC address must be output Duplicate Filter Shows whether the MAC address is listed as a source MAC address in the duplicate filter table Proxy Node Shows whether the MAC address is listed as a source MAC address in the proxy node table Functional description and configuration using Web Based Management 7 10 The Switch menu SCALANCE X 200RNA 126 Operating Instructions 1...

Страница 127: ...provides you with an overview of the data traffic and any problems on the network 7 10 6 Packet Size Statistic Received frames sorted by length The Packet Size Statistic dialog box displays how many packets of which size were received at each port If you click the Reset Counters button you reset this counter for all ports Functional description and configuration using Web Based Management 7 10 The...

Страница 128: ...presentation of the statistics This dialog box displays the number of frames received at each port graphically The display is dependent on the frame length There is a separate element in the graphic for each of the following ranges 64 bytes 65 127 bytes 128 255 bytes 256 511 bytes Functional description and configuration using Web Based Management 7 10 The Switch menu SCALANCE X 200RNA 128 Operati...

Страница 129: ...ckets for this port When the percentage is calculated ranges are included only if their check boxes are selected With the Previous Port and Next Port buttons you can change to the display of the previous or next port 7 10 7 Packet Type Statistic Received frames sorted by type The Packet Type Statistic dialog box displays how many frames of the type unicast multicast and broadcast were received and...

Страница 130: ...hical representation of the counter value Graphic representation of the statistics This dialog box displays the number of frames received at each port graphically The display depends on the packet type There is a separate element in the graphic for each of the following ranges Unicast Multicast Broadcast Functional description and configuration using Web Based Management 7 10 The Switch menu SCALA...

Страница 131: ...entage column shows the packets of a certain type as a percentage of the total packets for this port When the percentage is calculated packet types are included only if their check boxes are selected With the Previous Port and Next Port buttons you can change to the display of the previous or next port Functional description and configuration using Web Based Management 7 10 The Switch menu SCALANC...

Страница 132: ...dersize Number of frames with a length less than 64 bytes Oversize Number of frames with a length greater than 1536 bytes Dropped L2 Number of frames that were discarded at the receiving port due to lack of resources on the switch If you click the Reset Counters button you reset this counter for all ports Figure 7 44 Packet Error Statistic Functional description and configuration using Web Based M...

Страница 133: ...tistic Graphic With the check box in the Packet Error column you decide the content of the graphic The value in the Packets column in the graphic is only displayed for a certain packet type if the appropriate check box is selected The Percentage column shows the errors of a certain type as a percentage of the total errors for this port When the percentage is calculated error types are included onl...

Страница 134: ...Number of valid B frames received at port PRP B Received B Frames at PRP A Port Number of B frames received at port PRP A error Received A Frames at PRP B Port Number of A frames received at port PRP B error If you click the Reset Counters button you reset this counter for all ports Figure 7 46 PRP Statistic Functional description and configuration using Web Based Management 7 10 The Switch menu S...

Страница 135: ...rames at Port P2 B Number of PRP A frames that were received at port P2 B error Received own Proxy Source MAC address Number of received frames with their own source MAC address error Received PRP or Standard Frames at HSR 1 Number of valid PRP or Standard Ethernet frames that were received at HSR 1 error Received PRP or Standard Frames at HSR 2 Number of valid PRP or Standard Ethernet frames that...

Страница 136: ...Figure 7 47 Redundancy Statistic Functional description and configuration using Web Based Management 7 10 The Switch menu SCALANCE X 200RNA 136 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 137: ...support automation siemens com WW view de 52323714 133400 Entry list Entry type Certificates Type of certificate Declaration of conformity Example German EG Konformitätserklärung SCALANCE X204RNA Example English Declaration of Conformity SCALANCE X204RNA EMC directive electromagnetic compatibility The devices of the type SCALANCE X 200RNA meet the requirements of the EC directive 2004 108 EEC Elec...

Страница 138: ...om WW view en 60612658 Configuration manual Working on the product To protect the product from electrostatic discharge personnel must first discharge any electrostatic charge from their body before touching the product Note The product was tested with a device that also complies with the standards listed above When operating the product with a device that does not comply with these standards adher...

Страница 139: ...nd IEC approvals The following products meet the FDA and IEC requirements listed below SFP module SFP991 1LD SFP module SFP991 1LH Figure 8 1 FDA and IEC approvals Notice for Australia C Tick The product meets the requirements of the AS NZS 2064 standard Class A Notice for Korea Kc The product meets the requirements of the Korea Certification UL Approval for Information Technology Equipment Underw...

Страница 140: ...Equipment Underwriters Laboratories Inc complying with UL 508 CSA C22 2 No 142 M1987 Table 8 1 Approvals Device type SCA LANCE cULus FM CE C Tick Kc ATEX95 Zone 2 E1 X204RNA UL 60950 1 CSA C22 2 No 60950 1 FM 3611 CL 1 Div 2 GP A B C D T CL 1 Zone 2 GP IIC T Ta EN 61000 6 4 EN 61000 6 2 AS NZS 2064 Class A Korea Certifi cation EN 60079 15 EN 60079 0 II 3 G Ex nA IIC T Gc KEMA 07 ATEX 0145X X204RNA...

Страница 141: ...ts of the following railway approvals EN 45545 2 Railway applications Fire protection on railway vehicles EN 50121 4 and EN 50121 3 2 Railway applications electromagnetic compatibility EN 50155 2007 Railway applications Electronic equipment used on rolling stock Note When used on railway stock a stabilized power supply must be used to comply with EN50155 Hardware version You will find the hardware...

Страница 142: ...Approvals and marking SCALANCE X 200RNA 142 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 143: ...ith SFP module Connectors for the power supply Plug in terminal block Connectors for the sig naling contact Plug in terminal block X204RNA 4 1 x 4 pin 1 x 2 pin X204RNA EEC 2 2 max 2 1 x 3 pin 1 x 3 pin Table 9 3 Electrical data Device type SCALANCE Supply voltage toler ance range Power loss typ Current consumption typ Overvoltage protection at input X204RNA 2 x 24 VDC SELV Safe ty Extra Low Volta...

Страница 144: ...iling flexible FRNC fes toon food cable 10 m TP cord over IE FC outlet RJ 45 0 100 m IE FC TP standard cable with IE FC RJ 45 plug 180 or over IE FC outlet RJ 45 with 0 90 m IE FC TP standard ca ble 10 m TP cord X204RNA X204RNA EEC Table 9 6 Permitted cable lengths fiber optic SFP modules only for SCALANCE X204RNA EEC 0 3 000 m Glass FO cable 62 5 125 µm multimode glass fiber 0 26 000 m Glass FO c...

Страница 145: ...mitted ambient conditions Device type SCALANCE Operating temperature Storage transporta tion temperature Relative humidity in operation Operating altitude at max xx C ambient temperature X204RNA 40 to 60 C 40 to 70 C 95 no condensation 2000 m at max 56 C 3000 m at max 50 C X204RNA EEC 40 to 70 C up to 85 C max 16 h 40 to 70 C 95 no condensation 2000 m at max 56 C 3000 m at max 50 C Note Note the o...

Страница 146: ...Technical specifications SCALANCE X 200RNA 146 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 147: ...ble GP 6XV1870 2B All IE FC FRNC cable GP 6XV1871 2F All IE TP ground cable 6XV1871 2G All IE FC TP festoon cable GP 6XV1871 2S All IE TP train cable 6XV1871 2T All IE FC TP food cable 6XV1871 2L All IE TP torsion cable 6XV1870 2F All Energy cable 2 x 0 75 6XV1812 8A All IE FC RJ 45 Plug 180 pack of 1 6GK1901 1BB10 2AA0 All IE FC RJ 45 Plug 180 pack of 10 6GK1901 1BB10 2AB0 All IE FC RJ 45 Plug 18...

Страница 148: ...μm 6XV1873 2R SCALANCE X204RNA EEC SM robust cable 4x19 125 900 µm 6XV1843 2R SCALANCE X204RNA EEC MM LC duplex plug 6GK1 901 0RB10 2AB0 SCALANCE X204RNA EEC SM LC duplex plug 6GK1 901 0SB10 2AB0 SCALANCE X204RNA EEC Other hardware C PLUG 6GK1900 0AB00 X 200RNA Software SOFTNET IE RNA 6GK1711 1EW12 0AA0 All Accessories and compatible devices 10 1 Accessories SCALANCE X 200RNA 148 Operating Instruc...

Страница 149: ...aged IE switch 6GK5104 2BB00 2AA3 ES 01 SCALANCE X106 1 unmanaged IE switch 6GK5106 1BB00 2AA3 ES 01 SCALANCE X108 unmanaged IE switch 6GK5108 0BA00 2AA3 ES 01 SCALANCE X108POE unmanaged IE switch 6GK5108 0PA00 2AA3 ES 01 SCALANCE X112 2 unmanaged IE switch 6GK5112 2BB00 2AA3 ES 01 SCALANCE X116 unmanaged IE switch 6GK5116 0BA00 2AA3 ES 01 SCALANCE X124 unmanaged IE switch 6GK5124 0BA00 2AA3 ES 01...

Страница 150: ...302 7EEC 24 VDC 6GK5302 7GD00 1EA3 V3 7 0 SCALANCE X302 7EEC 24 VDC redundant power supply unit 6GK5302 7GD00 2EA3 V3 7 0 SCALANCE X302 7EEC 24 VDC power supply unit CONFOR MAL COATING 6GK5302 7GD00 1GA3 V3 7 0 SCALANCE X302 7EEC 24 VDC redundant power supply unit CONFORMAL COATING 6GK5302 7GD00 2GA3 V3 7 0 SCALANCE X302 7EEC 100 240 VAC VDC power supply unit 6GK5302 7GD00 3EA3 V3 7 0 SCALANCE X30...

Страница 151: ...E switch 24 VDC cable out let front 6GK5324 0GG00 1AR2 V3 7 0 SCALANCE XR324 12M managed IE switch 24 VDC cable out let rear 6GK5324 0GG00 1HR2 V3 7 0 SCALANCE XR324 12M managed IE switch 230 VAC cable outlet front 6GK5324 0GG00 3AR2 V3 7 0 SCALANCE XR324 12M managed IE switch 230 VAC cable outlet rear 6GK5324 0GG00 3HR2 V3 7 0 SCALANCE XR324 4M EEC managed IE switch 1 X 24 VDC cable outlet front ...

Страница 152: ...1EX20 0XE0 V2 1 CP 443 1 6GK7443 1EX30 0XE0 V3 0 CP 443 1 RNA 6GK7443 1RX00 0XE0 V1 0 CP 442 1 RNA 6GK7442 1RX00 0XE0 V1 0 Information about the product version ES or the firmware version V as of which PRP is supported The devices listed above are not suitable for use in rings in which the High availability Seamless Redundancy Protocol HSR is used Only devices equipped with HSR interfaces can be u...

Страница 153: ...Dimension drawings 11 Figure 11 1 SCALANCE X204RNA front view SCALANCE X 200RNA Operating Instructions 10 2016 C79000 G8976 C342 04 153 ...

Страница 154: ...Figure 11 2 SCALANCE X204RNA side view Dimension drawings SCALANCE X 200RNA 154 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 155: ...Figure 11 3 SCALANCE X204RNA EEC front view Dimension drawings SCALANCE X 200RNA Operating Instructions 10 2016 C79000 G8976 C342 04 155 ...

Страница 156: ...Figure 11 4 SCALANCE X204RNA EEC side view Dimension drawings SCALANCE X 200RNA 156 Operating Instructions 10 2016 C79000 G8976 C342 04 ...

Страница 157: ...mes 132 CRC 132 Dropped L2 132 Oversize 132 Undersize 132 F Factory Defaults 85 Fault mask 99 FM approval 139 G Glossary 11 Group Name 110 112 H Hazardous Ex area 14 HTTPS Only 104 I IP address 75 104 105 Configuration options 75 K Kc approval 139 L LED simulation 79 M MAC address 104 MDI MDIX autocrossover function 36 41 N NCM PC 75 Network topology 17 20 High availability Redundancy Ring 21 Para...

Страница 158: ...SNMP 106 SNMP trap 108 SNTP 104 SSH 104 Statistics 127 STEP 7 75 Subnet mask 74 104 Support 9 Switch Switch Forwarding Database 125 Syslog 104 119 T TELNET 104 Time of day SNTP Simple Network Time Protocol 121 Time zone 122 Time of day synchronization 121 UTC time 122 Time zone 122 Timeout 113 Training 10 U UL approval to UL 508 139 to UL 60950 139 UL mark 9 User Name 112 UTC time 122 W Web Based ...

Отзывы: