instabus EIB
Technical Product Information
August 2005
Socket outlet switch wave S 564
5WG3 564-7AB11
Technical Manual
S 564, 4 pages
Siemens AG
Automation and Drives Group
Update: http://www.siemens.de/gamma
©
Siemens AG 2005
Electrical Installation Technology
Subject to change without prior notice
P.O. Box 10 09 53, D-93009 Regensburg
2.20.7.1/2
Connections
•
socket outlet receptacle with side grounding contacts
for the connection of any load up to 16A (resistive)
•
socket outlet plug with side grounding contacts to be
plugged in any socket outlet receptacle with side
grounding contacts fused with at most 16A.
Breaking capacity
•
socket outlet receptacle and plug connected via relay
•
Rated voltage; AC 230 V, 50Hz
•
Rated current: 16 A
•
Switching cycles: > 20.000
if used with Incandescent lamps up to 1000W
Electrical safety
•
Pollution degree (according to IEC 60664-1): 2
•
Protection (according to EN 60529): IP 20
•
Overvoltage category (according to IEC 60664-1): III
•
Device complies with EN 60669-2-1 and IEC 60664-1
Electromagnetic compatibility
Complies with EN 60669-2-1, EN 301489, EN 300220
Environmental specifications
•
Climatic conditions: EN 50090-2-2
•
Ambient operating temperature: - 5 ... + 45
°
C
•
Storage temperature: - 25 ... + 70
°
C
•
Relative humidity (non-condensing): 5% to 93%
Approbation
VDE Approbation in preparation, complies
- Standard
radio frequency wave
easy mode push button EP
CE Norm
Complies with EN 61058-1, DIN VDE 0620, DIN 49440 /
DIN 4944, EMV-regulations (residential building), low
voltage regulations and R&TTE-regulations:
The CE declaration can be inspected at:
SIEMENS AG
Siemensstraße 10
D-93055 Regensburg
Frequency band
868 MHz (transmission is not susceptible to interference;
frequency band reserved for system and security applica-
tions)
Range of radio control
approx. 100 m (applying to free field applications)
Location and Function of Display and
Operating Elements
A1
A2
A3
A4
A1
socket outlet receptacle with side grounding contacts
A2 Status LED
A3 Push button for local operation
A4 socket outlet plug with side grounding contacts
Mounting and commissioning
Mounting: (Figure 2)
The socket outlet switch wave is plugged into a socket
outlet receptacle with side grounding contacts manually.
To avoid radio interference the socket outlet switch wave
should be mounted in a way that the cable of the
switched device does not run across the housing.
Dismantling:
Remove the socket outlet switch wave manually out of
the socket outlet receptacle.