Technical Specifications
5
This section provides important technical specifications related to the device.
5.1
Power Supply Specifications
Note
When determining cable lengths, make sure the minimum input voltage for the pow-
er supply is provided at the power source.
Input Range
Power Sup-
ply Type
Min
Max
Internal
Fuse Rating
Maximum
Power Con-
Insulation
88 VDC
300 VDC
HI
85 VAC
264 VAC
65 W
88 VDC
300 VDC
HIP
85 VAC
264 VAC
3.15 A(T)
65 W
2800 VDC
for 1 minute
24
24P
13 VDC
36 VDC
10 A(T)
63.5 W
48
48P
36 VDC
72 VDC
3.15 A(T)
60 W
1500 VDC
for 1 minute
12
12P
9 VDC
15 VDC
12 A
67 W
1500 VAC or
2121 VDC
for 1 minute
Power consumption varies based on the device configuration. A typical RUGGEDCOM RX1511 chassis
will consume approximately 35 W of power.
(T) denotes time-delay fuse.
5.2
Failsafe Relay Specifications
Maximum Switching Voltage
Rated Switching Current
Isolation
30 VDC
5 A
125 VDC
0.1 A
, 0.15 A
250 VAC
6.25 A
2800 VDC for 1 minute be-
tween coil and contacts
Inductive load R/L = 7 ms
Resistive load
RUGGEDCOM RX1511
Installation Manual, 07/2019, C79000-G8976-1056
43