RUGGEDCOM RSL910
Installation Guide
Chapter 5
Technical Specifications
Power Supply Specifications
29
Technical Specifications
This section provides important technical specifications related to the device.
CONTENTS
•
Section 5.1, “Power Supply Specifications”
•
Section 5.2, “Failsafe Alarm Relay Specifications”
•
Section 5.3, “Copper Ethernet Port Specifications”
•
Section 5.4, “Operating Environment”
•
Section 5.5, “Mechanical Specifications”
•
Section 5.6, “Dimension Drawings”
Section 5.1
Power Supply Specifications
NOTE
When determining cable lengths, make sure the minimum input voltage for the power supply is
provided at the power source.
Hazardous Environments
Input Range
Power Supply Type
Minimum
Maximum
Internal
Fuse Rating
a
Isolation
Maximum Power
Consumption
b
125 VDC
250 VDC
3.15 A(T)
4 kVAC
10 W
HI
100 VAC
240 VAC
3.15 A(T)
4 kVAC
10 W
24
12 VDC
24 VDC
3.15 A(T)
1.5 kVDC
10 W
48
37 VDC
72 VDC
3.15 A(T)
1.5 kVDC
10 W
a
(T) denotes time-delay fuse.
b
Power consumption varies based on configuration.