RUGGEDCOM RSG2300
Installation Guide
Chapter 4
Technical Specifications
Power Supply Specifications
29
Technical Specifications
The following sections provide important technical specifications related to the device and available modules:
•
Section 4.1, “Power Supply Specifications”
•
Section 4.2, “Failsafe Relay Specifications”
•
Section 4.3, “Supported Networking Standards”
•
Section 4.4, “Copper Ethernet Port Specifications”
•
Section 4.5, “Fiber Optic Ethernet Port Specifications”
•
Section 4.6, “Operating Environment”
•
Section 4.7, “Mechanical Specifications”
Section 4.1
Power Supply Specifications
CAUTION!
Electrical hazard – risk of damage to the device. Disconnect the device from the power supply if power
input is above or below the specified input range.
Input Range
Power Supply Type
Minimum
Maximum
Internal Fuse Rating
ab
Maximum Power
Consumption
c
24 VDC
10 VDC
36 VDC
6.3 A(F)
48 VDC
36 VDC
59 VDC
3.15 A(T)
HI (125/250 VDC)
d
88 VDC
300 VDC
2 A(T)
HI (110/230 VAC)
d
85 VAC
264 VAC
2 A(T)
25 W
a
(F) denotes fast-acting fuse
b
(T) denotes time-delay fuse.
c
Power consumption varies based on configuration. 10/100Base-TX ports consume roughly 1 W less than fiber optic ports.
d
The HI power supply is the same power supply for both AC and DC.
Section 4.2
Failsafe Relay Specifications
Parameter
Value (Resistive Load)
Max Switching Voltage
240 VAC, 125 VDC
Rated Switching Current
2 A @ 240 VAC, 0.15 A @ 125 VDC, 2 A @ 30 VDC
Содержание RUGGEDCOM RSG2300
Страница 4: ...RUGGEDCOM RSG2300 Installation Guide iv ...
Страница 12: ...RUGGEDCOM RSG2300 Installation Guide Chapter 1 Introduction Description 4 ...
Страница 36: ...RUGGEDCOM RSG2300 Installation Guide Chapter 3 Communication Ports BNC Ports 28 ...
Страница 46: ...RUGGEDCOM RSG2300 Installation Guide Chapter 5 Dimension Drawings 38 ...