Technical Specifications
5.3 Copper Ethernet Port Specifications
Maximum Switching Voltage
Rated Switching Current
Isolation
30 VDC
1 A
80 VDC
30 VAC
0.3 A
1500 V
rms
for 1 minute
5.3
Copper Ethernet Port Specifications
The following details specifications for all standard and optional fixed copper
Ethernet ports that can be ordered with the RUGGEDCOM RS900G. For more
information about the SFP ports, refer to
"Copper Ethernet Ports (Page 19)"
.
Note
• Maximum segment length is greatly dependent on factors such as fiber quality,
and the number of patches and splices. Consult a Siemens Sales associate when
determining maximum segment distances.
• All optical power numbers are listed as dBm averages.
• F51 transceivers are rated for -40 to 85 °C (-40 to 185 °F).
Connector
Duplex
Cable Type
Wiring
Standard
Maximum
Distance
Isolation
RJ45
FDX/HDX
> CAT-5
TIA/EIA
T568A/B
100 m (328 ft)
1.5 kV
micro-D
FDX/HDX
> CAT-5
TIA/EIA
T568A/B
100 m (328 ft)
1.5 kV
Auto-Negotiating.
Shielded or unshielded.
Auto-crossover and auto-polarity.
Typical distance. Dependent on the number of connectors and splices.
5.4
Fiber Optic Ethernet Port Specifications
The following details specifications for all optional fixed fiber optic Ethernet ports
that can be ordered with the RUGGEDCOM RS900G. For more information about the
SFP ports, refer to
"Fiber Optic Ethernet Ports (Page 20)"
Note
• Maximum segment length is greatly dependent on factors such as fiber quality,
and the number of patches and splices. Consult a Siemens Sales associate when
determining maximum segment distances.
• All optical power numbers are listed as dBm averages. To convert from average
to peak add 3 dBm. To convert from peak to average, subtract 3 dBm.
• All cabling is duplex type unless otherwise specified.
24
RUGGEDCOM RS900G
Installation Manual, 01/2021, C79000-G8976-1025-08