Chapter 5

Technical Specifications

Power Supply Specifications

25

Technical Specifications

This section provides important technical specifications related to the device.

CONTENTS

Section 5.1, “Power Supply Specifications”

Section 5.2, “Failsafe Alarm Relay Specifications”

Section 5.3, “Copper Ethernet Port Specifications”

Section 5.4, “Fiber Optic Ethernet Port Specifications”

Section 5.5, “Operating Environment”

Section 5.6, “Mechanical Specifications”

Section 5.7, “Dimension Drawings”

Section 5.1

Power Supply Specifications

NOTE

When determining cable lengths, make sure the minimum input voltage for the power supply is

provided at the power source.

Hazardous Environments

Input Range

Power Supply Type

Minimum

Maximum

Internal

Fuse Rating

a

Isolation

Maximum Power

Consumption

b

125 VDC

250 VDC

3.15 A(T)

4 kVAC

10 W

HI

100 VAC

240 VAC

3.15 A(T)

4 kVAC

10 W

24

12 VDC

24 VDC

3.15 A(T)

1.5 kVDC

10 W

48

37 VDC

72 VDC

3.15 A(T)

1.5 kVDC

10 W

a

(T) denotes time-delay fuse.

b

Power consumption varies based on configuration.

Содержание RUGGEDCOM RS900F

Страница 1: ...RUGGEDCOM RS900F Installation Guide 01 2019 RC1350 EN 03 Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 ...

Страница 2: ...nt and or networks They are important components in a holistic industrial security concept With this in mind Siemens products and solutions undergo continuous development Siemens recommends strongly that you regularly check for product updates For the secure operation of Siemens products and solutions it is necessary to take suitable preventive action e g cell protection concept and integrate each...

Страница 3: ...Siemens Address Siemens Canada Ltd Industry Sector 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 264 0006 Tel 1 905 856 5288 Fax 1 905 856 1995 E mail ruggedcom info i ia siemens com Web https www siemens com ruggedcom ...

Страница 4: ...RUGGEDCOM RS900F Installation Guide iv ...

Страница 5: ...orted Fiber Optic Cables 5 1 6 Tamper Evident Security Seals 5 Chapter 2 Installing the Device 7 2 1 General Procedure 8 2 2 Unpacking the Device 8 2 3 Installing the Device in Hazardous Locations 8 2 4 Mounting the Device 9 2 4 1 Mounting the Device on a DIN Rail 10 2 4 2 Mounting the Device to a Panel 11 2 5 Connecting the Failsafe Alarm Relay 12 2 6 Connecting Power 13 2 6 1 Connecting High AC ...

Страница 6: ... Relay Specifications 26 5 3 Copper Ethernet Port Specifications 26 5 4 Fiber Optic Ethernet Port Specifications 27 5 5 Operating Environment 28 5 6 Mechanical Specifications 28 5 7 Dimension Drawings 28 Chapter 6 Certification 31 6 1 Approvals 31 6 1 1 CSA 31 6 1 2 CSA Sira 32 6 1 3 European Union EU 33 6 1 4 FCC 33 6 1 5 FDA CDRH 34 6 1 6 ISED 34 6 1 7 TÜV SÜD 34 6 1 8 RoHS 34 6 1 9 Other Approv...

Страница 7: ...ssing Documentation Training Customer Support Alerts The following types of alerts are used when necessary to highlight important information DANGER DANGER alerts describe imminently hazardous situations that if not avoided will result in death or serious injury WARNING WARNING alerts describe hazardous situations that if not avoided may result in serious injury and or equipment damage CAUTION CAU...

Страница 8: ...unique mix of IT Telecommunications expertise combined with domain knowledge in the utility transportation and industrial markets allows Siemens to provide training specific to the customer s application For more information about training services and course availability visit https www siemens com ruggedcom or contact a Siemens Sales representative Customer Support Customer support is available ...

Страница 9: ... Installation Guide Preface Customer Support ix Contact a local Siemens representative from Sales Technical Support Training etc Ask questions or share knowledge with fellow Siemens customers and the support community ...

Страница 10: ...Preface RUGGEDCOM RS900F Installation Guide x Customer Support ...

Страница 11: ...worldwide operability as well as dual redundant reversible polarity 24 VDC and 48 VDC power supply inputs for high availability applications requiring dual or backup power inputs The RUGGEDCOM RS900F s superior ruggedized design and embedded RUGGEDCOM Rugged Operating System ROS provides superior system reliability and advanced networking features making it ideally suited for creating Ethernet net...

Страница 12: ...ty Optional Conformal coated printed circuit boards Universal Power Supply Options Fully integrated power supply Universal high voltage range 125 250 VDC or 100 240 VAC Hazardous Environments 88 300 VDC or 85 264 VAC Non Hazardous Environments Dual low voltage DC inputs 24 or 48 VDC Terminal blocks for reliable maintenance free connections CSA UL 60950 1 safety approved to 85 C 185 F Section 1 2 D...

Страница 13: ...ection 3 1 Connecting to the Device RESET Button Shuts down and restarts the device For more information refer to Section 3 3 Resetting the Device Communication Ports Communication ports in general receive and transmit data as well as provide access to the RUGGEDCOM ROS F Web interface For more information about the various ports available refer to Chapter 4 Communication Ports Failsafe Alarm Rela...

Страница 14: ...ird party make sure it has been fully decommissioned For more information refer to the associated User Guide Recycling and Disposal For environmentally friendly recycling and disposal of this device and related accessories contact a facility certified to dispose of waste electrical and electronic equipment Recycling and disposal must be done in accordance with local regulations Section 1 5 Cabling...

Страница 15: ...tandards FIPS140 2 FIPS compliant tamper evident security seals are applied to potential access points on this device Security seals provide evidence of unauthorized tampering or removal of components IMPORTANT Worn damaged or missing seals must be replaced immediately Replacement seals are available for purchase from Siemens For more information contact a Siemens Sales representative There are th...

Страница 16: ...Chapter 1 Introduction RUGGEDCOM RS900F Installation Guide 6 Tamper Evident Security Seals ...

Страница 17: ...hazardous radiation exposure IMPORTANT This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void Changes or modifications not expressly approved by Siemens Canada Ltd could invalidate specifications test results and agency approvals and void the user s authority to operate the equipment IMPORTANT This product should be ins...

Страница 18: ...6 Configure the device Section 2 2 Unpacking the Device When unpacking the device do the following 1 Inspect the package for damage before opening it 2 Visually inspect each item in the package for any physical damage 3 Verify all items are included IMPORTANT If any item is missing or damaged contact Siemens for assistance Section 2 3 Installing the Device in Hazardous Locations The RUGGEDCOM RS90...

Страница 19: ...o not disconnect or open equipment unless power has been switched off or the area is known to be non hazardous IMPORTANT Débrancher ou ouvrir l équipment seulement si l alimnetation a été coupée ou si l on sait que la zone ne pose aucun danger IMPORTANT Substitution of the components may impair suitability for Class I Division 2 IMPORTANT Le remplacement de composants pourrait compromettre l admis...

Страница 20: ...ng term reliability of all equipment mounted in the rack space NOTE For detailed dimensions of the device with either DIN rail or panel hardware installed refer to Section 5 7 Dimension Drawings CONTENTS Section 2 4 1 Mounting the Device on a DIN Rail Section 2 4 2 Mounting the Device to a Panel Section 2 4 1 Mounting the Device on a DIN Rail For DIN rail installations the RS900F can be equipped w...

Страница 21: ... limited use a slotted screwdriver or a similar tool to reach the release Section 2 4 2 Mounting the Device to a Panel For panel installations the RUGGEDCOM RS900F can be equipped with panel adapters pre installed on the top and bottom of the chassis The adapters allow the device to be attached to a panel using screws To mount the device to a panel do the following 1 Prepare mounting holes in the ...

Страница 22: ...owered and there are no active alarms If the device is not powered or if an active alarm is configured the relay opens the NO contact and closes the NC Normally Closed contact NOTE Control of the failsafe relay output is configurable through ROS F One common application for this relay is to signal an alarm if a power failure occurs For more information refer to the ROS F User Guide for the RUGGEDC...

Страница 23: ...ecting terminal blocks Equipment must be installed according to applicable local wiring codes and standards All line to ground transient energy is shunted to the Surge Ground terminal In cases where users require the inputs to be isolated from ground remove the ground braid between Surge and Chassis Ground Note that all line to ground transient protection circuitry will be disabled CONTENTS Sectio...

Страница 24: ...ble connects transient suppression circuitry to chassis ground and must be removed in order to avoid damage to transient suppression circuitry during testing NOTE Torque all terminal connections to 0 6 N m 5 lbf in 1 Secure the power terminal block to the device 2 Connect the positive wire from the power source to the positive live L terminal on the terminal block 4 1 2 3 Figure 6 Terminal Block W...

Страница 25: ... from the power source to the chassis groun terminal on the terminal block Section 2 6 2 Connecting Low DC Power RUGGEDCOM RS900F s equipped with 24 or 48 V power supply inputs feature reverse polarity protection and dual power supply inputs allowing the device to accept redundant connections to a single DC power supply To connect a low DC power supply to the device do the following NOTE Torque al...

Страница 26: ...ring Single DC Power Supply Inputs 1 Positive Terminal 2 Negative Terminal 3 Surge Ground Terminal 4 Braided Ground Cable 3 Connect the negative wire from the power source to the negative terminal on the terminal block 4 Optional If a redundant connection is required repeat Step 2 and Step 3 to connect the secondary power inputs ...

Страница 27: ...al 3 Surge Ground Terminal 4 Braided Ground Cable 5 Using a braided wire or other appropriate grounding wire connect the surge ground terminal to the chassis ground connection The surge ground terminal is used as the ground conductor for all surge and transient suppression circuitry internal to the unit 6 Connect the ground wire from the power source to the chassis groun terminal on the terminal b...

Страница 28: ...Chapter 2 Installing the Device RUGGEDCOM RS900F Installation Guide 18 Connecting Low DC Power ...

Страница 29: ...r the RUGGEDCOM RS900F IMPORTANT Ethernet cables should be only be connected disconnected in a non hazardous area or when the device is not energized Console Port Connect a workstation directly to the RS232 serial console port to access the boot time control and RUGGEDCOM ROS F console interface The console port provides access to RUGGEDCOM ROS F s console interface IMPORTANT The serial console po...

Страница 30: ...gement switch and access the RUGGEDCOM ROS F console and Web interfaces via the device s IP address The factory default IP address for the RUGGEDCOM RS900F is https 192 168 0 1 For more information about available ports refer to Chapter 4 Communication Ports Section 3 2 Configuring the Device Once the device is installed and connected to the network it must be configured All configuration manageme...

Страница 31: ...and 8 3 Port 9 Port Type 1 to 6 Copper Ethernet Ports 10 100Base TX 7 and 8 Copper 10 100Base TX or Fiber Optic 100Base FX Ethernet Ports 9 Fast Ethernet Port 10 100Base TX or 100Base FX CONTENTS Section 4 1 Copper Ethernet Ports Section 4 2 Fiber Optic Ethernet Ports Section 4 1 Copper Ethernet Ports The RUGGEDCOM RS900F supports multiple 10 100Base TX Ethernet ports that allow connection to stan...

Страница 32: ...cates the state of the port 1 2 Figure 12 RJ45 Port LEDs 1 Speed LED 2 Link Activity LED LED State Description Yellow The port is operating at 100 Mbps Speed Off The port is operating at 10 Mbps Yellow Solid Link established Yellow Blinking Link activity Link Activity Off No link detected Pin Out The following is the pin out for the RJ45 male connectors 1 8 Figure 13 RJ45 Ethernet Port Pin Configu...

Страница 33: ...ly connected and matched to establish a proper link Port Types 2 1 Figure 14 MTRJ Port 1 Tx Connector 2 Rx Connector 2 1 Figure 15 LC Port 1 Tx Connector 2 Rx Connector 2 1 Figure 16 SC Port 1 Tx Connector 2 Rx Connector 2 1 Figure 17 ST Port 1 Tx Connector 2 Rx Connector LEDs Each port features an LED that indicates the link activity state of the port State Description Yellow Solid Link establish...

Страница 34: ...Chapter 4 Communication Ports RUGGEDCOM RS900F Installation Guide 24 Fiber Optic Ethernet Ports ...

Страница 35: ...perating Environment Section 5 6 Mechanical Specifications Section 5 7 Dimension Drawings Section 5 1 Power Supply Specifications NOTE When determining cable lengths make sure the minimum input voltage for the power supply is provided at the power source Hazardous Environments Input Range Power Supply Type Minimum Maximum Internal Fuse Rating a Isolation Maximum Power Consumption b 125 VDC 250 VDC...

Страница 36: ...ption may vary based on configuration Section 5 2 Failsafe Alarm Relay Specifications Hazardous Environments Maximum Switching Voltage Rated Switching Current Isolation 30 VDC 1 A 80 VDC 30 VAC 0 3 A 1500 Vrms for 1 minute Non Hazardous Environments Maximum Switching Voltage Rated Switching Current Isolation 30 VDC 2 A 60 W 125 VDC 0 24 A 30 W 125 VAC 0 5 A 62 5 W 220 VDC 0 24 A 60 W 250 VAC 0 25 ...

Страница 37: ...nvert from peak to average subtract 3 dBm Maximum segment length is greatly dependent on factors such as fiber quality and the number of patches and splices Consult a Siemens sales associate when determining maximum segment distances Tx dBm Mode Connector Type Tx λ nm j Cable Type μm Minimum Maximum Rx Sensitivity dBm Rx Saturation dBm Distance km j Power Budget dB 50 125 22 5 14 33 5 14 2 11 MM M...

Страница 38: ...re k 40 to 85 C 40 to 185 F Ambient Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity l 5 to 95 Maximum Altitude 2000 m k Measured from a 30 cm 12 in radius surrounding the center of the enclosure l Non condensing Section 5 6 Mechanical Specifications Weight 1 2 kg 2 7 lbs Ingress Protection IP30 Enclosure 20 AWG Galvanized Steel Section 5 7 Dimension Drawings NOTE All dimension...

Страница 39: ...RUGGEDCOM RS900F Installation Guide Chapter 5 Technical Specifications Dimension Drawings 29 99 06 187 96 168 66 65 3 116 59 7 87 Figure 18 Overall Dimensions ...

Страница 40: ...Chapter 5 Technical Specifications RUGGEDCOM RS900F Installation Guide 30 Dimension Drawings 13 64 101 6 11 2 78 74 120 65 194 06 83 20 183 90 130 2 Figure 19 Panel and DIN Rail Mount Dimensions ...

Страница 41: ...ch the RUGGEDCOM RS900F complies CONTENTS Section 6 1 1 CSA Section 6 1 2 CSA Sira Section 6 1 3 European Union EU Section 6 1 4 FCC Section 6 1 5 FDA CDRH Section 6 1 6 ISED Section 6 1 7 TÜV SÜD Section 6 1 8 RoHS Section 6 1 9 Other Approvals Section 6 1 1 CSA This device meets the requirements of the following Canadian Standards Association CSA standards under certificate 16 70065161 CAN CSA C...

Страница 42: ...CSA symbol that indicates compliance with both Canadian and U S requirements C US It is specifically approved for use in hazardous locations with the following markings Class I Division 2 Groups A B C D T4 Ex nA nC IIC T4 Gc Class I Zone 2 AEx nA nC IIC T4 Gc Section 6 1 2 CSA Sira When marked with the following ATEX marking this device is approved for use in hazardous locations under certificate ...

Страница 43: ...Limits and Methods of Measurement The device is marked with a CE marking and can be used throughout the European community A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd For contact information refer to Contacting Siemens Section 6 1 4 FCC This device has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rul...

Страница 44: ...t 1 General Requirements Bi National standard with UL 60950 1 UL 60950 1 Information Technology Equipment Safety Part 1 General Requirements Section 6 1 8 RoHS This device is declared by Siemens Canada Ltd to meet the requirements of the following RoHS Restriction of Hazardous Substances directives for the restricted use of certain hazardous substances in electrical and electronic equipment China ...

Страница 45: ... IEC 61000 4 2 ESD Enclosure Air 15 kV 4 IEC 61000 4 3 Radiated RFI Enclosure Ports 20 V m Signal Ports 4 kV 2 5 kHz x DC Power Ports 4 kV 4 AC Power Ports 4 kV 4 IEC 61000 4 4 Burst Fast Transient Earth Ground Ports 4 kV 4 Signal Ports 4 kV Line to Ground 2 kV 4 DC Power Ports 2 kV Line to Ground 1 kV Line to Line 3 IEC 61000 4 5 Surge AC Power Ports 4 kV Line to Ground 2 kV Line to Line 4 Signal...

Страница 46: ...ielectric Strength AC Power Ports 2 kV Signal Ports 5 kV Failsafe Relay Output DC Power Ports 5 kV IEC 60255 5 HV Impulse AC Power Ports 5 kV EMC Immunity Type Tests per IEEE 1613 NOTE The RUGGEDCOM RS900F meets Class 2 requirements for an all fiber configuration and Class 1 requirements for copper ports Class 1 allows for temporary communication loss while Class 2 requires error free and interrup...

Страница 47: ...rts 1 5 kV Dielectric Strength AC Power Ports 2 kV Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068 2 1 Cold Temperature Test Ad 40 C 40 F 16 Hours IEC 60068 2 2 Dry Heat Test Bd 85 C 185 F 16 Hours IEC 60068 2 30 Humidity Damp Heat Cyclic Test Db 95 Non Condensing 55 C 131 F 6 Cycles IEC 60255 21 1 Vibration 2 g 10 to 150 Hz Class 2 IEC 60255 21 2 Shock 30 g 11 ms C...

Страница 48: ...Chapter 6 Certification RUGGEDCOM RS900F Installation Guide 38 EMC and Environmental Type Tests ...

Отзывы: