RUGGEDCOM RS416
Installation Guide
Chapter 4
Technical Specifications
Serial Port Specifications
29
Mode
Connector
Type
Cable
Type (μm)
Tx λ (nm)
k
Tx Min.
(dBm)
Tx Max.
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(km)
k
Power
Budget
(dB)
50/125
-22.5
8.5
62.5/125
-19
12
MM
SC
50/125
1300
-22.5
-14
-31
-14
2
8.5
62.5/125
-19
12
MM
MTRJ
50/125
1300
-22.5
-14
-31
-14
2
8.5
SM
ST
9/125
1300
-15
-8
-32
-3
20
17
SM
SC
9/125
1300
-15
-8
-31
-7
20
16
SM
LC
9/125
1300
-15
-8
-34
-7
20
19
SM
LC
9/125
1300
-15
-8
-34
-7
20
19
SM
SC
9/125
1300
-5
0
-34
-3
50
29
SM
LC
9/125
1300
-5
0
-35
3
50
30
SM
SC
9/125
1300
0
5
-37
0
90
37
SM
LC
9/125
1300
0
5
-37
0
90
37
MTRJ
62.5/125
-19
12
MM
LC
50/125
1300
-22.5
-14
-31
-14
2
8.5
k
Typical.
Section 4.5
Serial Port Specifications
This section details specifications for ports that can be equipped on the RS416.
CONTENTS
•
Section 4.5.1, “Copper Serial Port Specifications”
•
Section 4.5.2, “Fiber Serial Port Specifications”
Section 4.5.1
Copper Serial Port Specifications
Baud Rate
Connector
Isolation
1200 to 230400 kbps
DB9
2.5 kV
1200 to 230400 kbps
RJ45
2.5 kV
1200 to 230400 kbps
DB9
2.5 kV
1200 to 230400 kbps
RJ45
2.5 kV
Содержание RUGGEDCOM RS416
Страница 4: ...RUGGEDCOM RS416 Installation Guide iv ...
Страница 34: ...RUGGEDCOM RS416 Installation Guide Chapter 3 Communication Ports Connecting Multiple RS485 Devices 26 ...
Страница 40: ...RUGGEDCOM RS416 Installation Guide Chapter 4 Technical Specifications Mechanical Specifications 32 ...
Страница 44: ...RUGGEDCOM RS416 Installation Guide Chapter 5 Dimension Drawings 36 ...
Страница 50: ...RUGGEDCOM RS416 Installation Guide Chapter 6 Certification EMC and Environmental Type Tests 42 ...