Chapter 4
System Administration
Configuring User Priviliges
119
7
6
5
4
3
2
1
Figure 75: TACACS Plus Server Form
1.
Server Box
2.
IP Address Box
3.
Auth TCP Port Box
4.
Auth Key Box
5.
Confirm Key Box
6.
Apply Button
7.
Reload
Button
3. Configure the following parameter(s) as required:
Parameter
Description
Server
Synopsis:
Any 8 characters
Default:
Primary
This field tells whether this configuration is for a Primary or a Backup Server.
IP Address
Synopsis:
###.###.###.### where ### ranges from 0 to 255
The Server IP Address.
Auth TCP Port
Synopsis:
1 to 65535
Default:
49
The IP Port on server.
Auth Key
Synopsis:
31 character ascii string
Default:
mySecret
The authentication key to be shared with server.
Confirm Auth Key
Synopsis:
31 character ascii string
The authentication key to be shared with server.
4. Set the privilege levels for each user type (i.e. admin, operator and guest). For more information, refer to
Section 4.6.2.2, “Configuring User Priviliges”
5. Click
Apply
.
Section 4.6.2.2
Configuring User Priviliges
Each authentication request includes a
priv_lvl
attribute that is used to grant access to the device. By
default, the attribute uses the following ranges:
•
15
represents the
admin
access level
•
2-14
represents the
operator
access level