![Siemens RUGGEDCOM RMC20 Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/siemens/ruggedcom-rmc20/ruggedcom-rmc20_installation-manual_380702033.webp)
Technical Specifications
4.3 Operating Environment
4.3
Operating Environment
Parameter
Range
Comments
Ambient Operating
Temperature
-40 to 85 °C
(-40 to 185 °F)
Measured from a 30 cm (12 in) radius
surrounding the center of the enclosure.
Ambient Relative Humidity
5% to 95%
Non-condensing
Ambient Storage Temperature
-40 to 85 °C
(-40 to 185 °F)
Typical. May change based on which fiber optic transceivers are installed. For more information, refer to
"Fiber Optic Port Specifications (Page 23)"
.
4.4
Mechanical Specifications
Weight
0.68 kg (1.5 lbs)
Ingress Protection
IP30
Enclosure
21 AWG Galvanized Steel
4.5
Dimension Drawings
Note
All dimensions are in millimeters, unless otherwise stated.
70.7
92.8
80.1
73.7
62.2
58.4
10
9.
0
99
.3
Figure 4.1
Overall Dimensions
24
RUGGEDCOM RMC20
Installation Manual, 04/2021, C79000-G8976-1007-10