RUGGEDCOM RMC
Installation Guide
Chapter 4
Technical Specifications
Power Supply Specifications
17
Technical Specifications
This section provides important technical specifications related to the device and available modules.
CONTENTS
•
Section 4.1, “Power Supply Specifications”
•
Section 4.2, “Copper Ethernet Port Specifications”
•
Section 4.3, “Fiber Optic Ethernet Port Specifications”
•
Section 4.4, “Supported Networking Standards”
•
Section 4.5, “Operating Environment”
•
Section 4.6, “Mechanical Specifications”
Section 4.1
Power Supply Specifications
Power Supply Type
Minimum Input
Maximum Input
Internal Fuse Rating
a
Max. Power
Consumption
24 VDC
18 VDC
36 VDC
48 VDC
36 VDC
59 VDC
88 VDC
300 VDC
HI
b
85 VAC
264 VAC
3.15A (T)
3 W
a
(T) denotes time-delay fuse.
b
This is the same power supply for both AC and DC.
Section 4.2
Copper Ethernet Port Specifications
The following details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM RMC.
Speed
c
Connector
Duplex
c
Cable Type
d
Wiring
Standard
e
Maximum
Distance
f
Isolation
g
10/100Base-TX
RJ45
FDX/HDX
> CAT-5
TIA/EIA T568A/B
100 m (328 ft)
1.5 kV
c
Auto-negotiating.
d
Shielded or unshielded.
e
Auto-crossover and auto-polarity.
Содержание RUGGEDCOM RMC
Страница 10: ...Chapter 1 Introduction RUGGEDCOM RMC Installation Guide 4 Description ...
Страница 22: ...Chapter 3 Communication Ports RUGGEDCOM RMC Installation Guide 16 Fiber Optic Ethernet Ports ...
Страница 26: ...Chapter 4 Technical Specifications RUGGEDCOM RMC Installation Guide 20 Mechanical Specifications ...
Страница 34: ...Chapter 6 Certification RUGGEDCOM RMC Installation Guide 28 EMC and Environmental Type Tests ...