Chapter 6
Certification
RUGGEDCOM MX5000RE
Installation Guide
50
MIL-STD Ratings
Section 6.2
MIL-STD Ratings
Standard
Description
Comments
MIL-STD 901D
Shock (Hard-Mounted)
Approved
MIL-STD 461
EMI
Approved
DOD-STD 1399
Magnetic Field (DC Magnetic Exposure)
Approved
MIL-STD 1399 (Section 300B)
Electrical Power Interface
Standards for Shipboard Systems
Approved
Section 6.3
EMC and Environmental Type Tests
The RUGGEDCOM MX5000RE has passed the following EMC and environmental tests.
IEC 61850-3 EMC Type Tests
Test
Description
Test Levels
Severity
Levels
Enclosure Contact
+/- 8 kV
4
IEC 61000-4-2
ESD
Enclosure Air
+/- 15 kV
4
IEC 61000-4-3
Radiated RFI
Enclosure Ports
20 V/m
Note
a
Signal ports
+/- 4 kV @ 2.5 kHz
Note
a
DC Power ports
+/- 4 kV
4
AC Power ports
+/- 4 kV
4
IEC 61000-4-4
Burst (Fast Transient)
Earth ground ports
+/- 4 kV
4
Signal ports
+/- 4 kV line-to-earth,
+/- 2 kV line-to-line
4
DC Power ports
+/- 2 kV line-to-earth,
+/- 1 kV line-to-line
3
IEC 61000-4-5
Surge
AC Power ports
+/- 4 kV line-to-earth,
+/- 2 kV line-to-line
4
Signal ports
10 V
3
D.C Power ports
10V
3
AC Power ports
10V
3
IEC 61000-4-6
Induced (Conducted) RFI
Earth ground ports
10V
3
100 A/m
IEC 61000-4-8
Magnetic Field
Enclosure Ports
1000 A/m for 1 s
5
Содержание RUGGEDCOM MX5000RE
Страница 4: ...RUGGEDCOM MX5000RE Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM MX5000RE Installation Guide x Customer Support ...
Страница 18: ...Chapter 1 Introduction RUGGEDCOM MX5000RE Installation Guide 8 Decommissioning and Disposal ...
Страница 38: ...Chapter 2 Installing the Device RUGGEDCOM MX5000RE Installation Guide 28 Connecting Power to the Enclosure ...
Страница 52: ...Chapter 4 Modules RUGGEDCOM MX5000RE Installation Guide 42 Installing Removing Power Supply Modules ...
Страница 56: ...Chapter 5 Technical Specifications RUGGEDCOM MX5000RE Installation Guide 46 Dimension Drawings ...