Installing the Device
2.4 Connecting the Failsafe Alarm Relay (If Equipped)
Removing the Device
To remove the device from a DIN rail, do the following:
1. Insert a flathead screwdriver into the slot of the sliding release and move it
down.
1
2
1
2
3
1
1
DIN Rail
2
DIN Rail Adapter
Figure 2.2
Removing the Device from a DIN Rail
2. Swing the bottom of the device away from the DIN rail.
3. Lift the device off the DIN rail.
2.4
Connecting the Failsafe Alarm Relay (If Equipped)
The failsafe relay can be configured to latch based on alarm conditions. The NO
(Normally Open) contact is closed when the unit is powered and there are no active
alarms. If the device is not powered or if an active alarm is configured, the relay
opens the NO contact and closes the NC (Normally Closed) contact.
Note
Control of the failsafe relay output is configurable through RUGGEDCOM i803. One
common application for this relay is to signal an alarm if a power failure occurs. For
more information, refer to the "RUGGEDCOM ROS Configuration Manual" for the
RUGGEDCOM i803.
The following shows the proper relay connections.
8
RUGGEDCOM i803
Installation Manual, 04/2022, C79000-G8976-1005-07