background image

Installing the Device
2.4 Connecting the Failsafe Alarm Relay (If Equipped)

Removing the Device

To remove the device from a DIN rail, do the following:
1. Insert a flathead screwdriver into the slot of the sliding release and move it

down.

1

2

1

2

3

1

     1    

DIN Rail

     2    

DIN Rail Adapter

Figure 2.2

Removing the Device from a DIN Rail

2. Swing the bottom of the device away from the DIN rail.
3. Lift the device off the DIN rail.

2.4

Connecting the Failsafe Alarm Relay (If Equipped)

The failsafe relay can be configured to latch based on alarm conditions. The NO

(Normally Open) contact is closed when the unit is powered and there are no active

alarms. If the device is not powered or if an active alarm is configured, the relay

opens the NO contact and closes the NC (Normally Closed) contact.

Note

Control of the failsafe relay output is configurable through RUGGEDCOM i803. One

common application for this relay is to signal an alarm if a power failure occurs. For

more information, refer to the "RUGGEDCOM ROS Configuration Manual" for the

RUGGEDCOM i803.

The following shows the proper relay connections.

8

RUGGEDCOM i803

Installation Manual, 04/2022, C79000-G8976-1005-07

Содержание RUGGEDCOM i803

Страница 1: ...Edition 04 2022 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM i803 https www siemens com ruggedcom ...

Страница 2: ...ged Ethernet Switches RUGGEDCOM i803 Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 04 2022 C79000 G8976 1005 07 ...

Страница 3: ...those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufacturers are used the...

Страница 4: ...king the Device 6 2 3 Mounting the Device 6 2 4 Connecting the Failsafe Alarm Relay If Equipped 8 2 5 Connecting Power 9 3 Device Management 13 3 1 Connecting to the Device 13 3 2 Configuring the Device 14 3 3 Inserting Removing the MicroSD MicroSDHC Card 14 4 Communication Ports 17 4 1 Copper Ethernet Ports 17 4 2 Fiber Optic Ethernet Ports 18 5 Technical Specifications 21 5 1 Power Supply Specif...

Страница 5: ...rtification 25 6 1 Approvals 25 6 1 1 CSA 25 6 1 2 ATEX IEC Ex 26 6 1 3 European Union EU 26 6 1 4 FCC 27 6 1 5 FDA CDRH 27 6 1 6 ISED 28 6 1 7 ISO 28 6 1 8 ACMA 28 6 1 9 RoHS 28 6 1 10 Other Approvals 29 6 2 EMC and Environmental Type Tests 29 iv RUGGEDCOM i803 Installation Manual 04 2022 C79000 G8976 1005 07 ...

Страница 6: ...mens com cs ww en view 109737193 SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document The glossary is available online via Siemens Industry Online Support SIOS at https support industry siemens com cs ww en view 50305045 Accessing Documentation The latest user documentation for RUGGEDCOM i803 is available online at https support industry siemens c...

Страница 7: ...ns customer service representative Training Siemens offers a wide range of educational services ranging from in house training of standard courses on networking Ethernet switches and routers to on site customized courses tailored to the customer s needs experience and application Siemens Educational Services team thrives on providing our customers with the essential practical skills to make sure u...

Страница 8: ...Qs and manuals Submit SRs or check on the status of an existing SR Contact a local Siemens representative from Sales Technical Support Training etc Ask questions or share knowledge with fellow Siemens customers and the support community Contacting Siemens Address Siemens Canada Ltd Digital Industries Process Automation 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888...

Страница 9: ...Preface Contacting Siemens viii RUGGEDCOM i803 Installation Manual 04 2022 C79000 G8976 1005 07 ...

Страница 10: ...ge of 20 to 60 C 4 to 140 F or optionally 40 to 85 C 40 to 185 F coupled with hazardous location certification Class 1 Division 2 allows the RUGGEDCOM i803 to be placed in almost any location The RUGGEDCOM i803 features a full array of intelligent functionality for high network availability and manageability The embedded Rugged Operating System ROS provides advanced Layer 2 and Layer 3 networking ...

Страница 11: ...ed circuit boards optional Die cast aluminum enclosure Memory Options Removable microSD microSDHC card Power Supply Dual low voltage DC inputs 24 VDC 9 32 VDC Compression fit connections CSA UL 60950 safety approved to 85 C 185 F 1 2 Description The RUGGEDCOM i803 features various ports controls and indicator LEDs on the front panel for connecting configuring and troubleshooting the device 4 9 10 ...

Страница 12: ...lable for the RUGGEDCOM i803 refer to Communication Ports Page 17 Access Plate The removable access plate provides access to the microSD microSDHC slot Use a microSD microSDHC card to load store the firmware and configuration for the device For information about using a microSD microSDHC card refer to Inserting Removing the MicroSD MicroSDHC Card Page 14 RS 232 Console Port The serial console port...

Страница 13: ... and Disposal For environmentally friendly recycling and disposal of this device and related accessories contact a facility certified to dispose of waste electrical and electronic equipment Recycling and disposal must be done in accordance with local regulations 1 5 Supported Fiber Optic Cables The following fiber optic cable types are supported under the stated conditions Distance m Cable Type Wa...

Страница 14: ...on exposure CAUTION Burn hazard risk of personal injury The surface of the device may be hot during operation or as a result of the ambient air temperature Wear appropriate personal protective equipment and use caution when working with or around the device NOTICE This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void C...

Страница 15: ...nnect power to the device and ground the device to safety Earth 5 Connect the device to the network 6 Configure the device 2 2 Unpacking the Device When unpacking the device do the following 1 Inspect the package for damage before opening it 2 Visually inspect each item in the package for any physical damage 3 Verify all items are included Note If any item is missing or damaged contact Siemens for...

Страница 16: ...stalled refer to Dimension Drawings Page 23 Mounting the Device To mount the device to a DIN rail do the following 1 Hook the top teeth of the adapter onto the DIN rail 1 2 2 3 1 DIN Rail 2 DIN Rail Adapter Figure 2 1 Mounting the Device to a DIN Rail 2 Insert a flathead screw driver into the slot of the sliding release and move it down 3 Push the device against the bottom of the DIN rail then let...

Страница 17: ...ailsafe relay can be configured to latch based on alarm conditions The NO Normally Open contact is closed when the unit is powered and there are no active alarms If the device is not powered or if an active alarm is configured the relay opens the NO contact and closes the NC Normally Closed contact Note Control of the failsafe relay output is configurable through RUGGEDCOM i803 One common applicat...

Страница 18: ...nal voltage to be connected To connect power to the device do the following NOTICE Terminals P1 P2 and GND are connected together internally As such if redundant power supplies are connected their negative terminals must be at the same potential Do not field wire the DC power supply on the DC mains or Battery mains Use minimum 16 gage wiring when connecting terminal blocks Equipment must be instal...

Страница 19: ...erminal block 1 2 3 4 1 Positive Terminal 2 Negative Terminal 3 GND Terminal 4 Chassis Ground Terminal Figure 2 4 Terminal Block Wiring Single DC Power Supply Input 2 Connect the negative wire from the power source to the negative terminal P1 or P2 on the terminal block 10 RUGGEDCOM i803 Installation Manual 04 2022 C79000 G8976 1005 07 ...

Страница 20: ...ng sure to connect the power supply to the P2 ports 1 2 1 2 3 4 1 Positive Terminal 2 Negative Terminal 3 GND Terminal 4 Chassis Ground Terminal Figure 2 5 Terminal Block Wiring Dual DC Power Supply Inputs 4 Connect the chassis ground terminal to protective Earth RUGGEDCOM i803 Installation Manual 04 2022 C79000 G8976 1005 07 11 ...

Страница 21: ...Installing the Device 2 5 Connecting Power 12 RUGGEDCOM i803 Installation Manual 04 2022 C79000 G8976 1005 07 ...

Страница 22: ...t provides access to RUGGEDCOM i803 s console and Web interfaces NOTICE The console port is intended to be used only as a temporary connection during initial configuration or troubleshooting Connection to the console port is made using an RJ45 to DB9 console cable The following is the pin out for the console port 1 8 Figure 3 1 RJ45 Console Port Pin Configuration Pin RJ45 Male DB9 Female Name Desc...

Страница 23: ...uration management is done via the RUGGEDCOM i803 interface For more information about configuring the device refer to the RUGGEDCOM ROS Configuration Manual associated with the installed software release 3 3 Inserting Removing the MicroSD MicroSDHC Card The RUGGEDCOM i803 accepts a microSD microSDHC card to support the following features Configuration update and backup Redundant firmware image Gr...

Страница 24: ...vice or sending the device to a third party To insert or remove a microSD microSDHC card do the following 1 Power down the device 2 Unscrew the retention screw and remove the access plate 1 2 3 1 Retention Screw 2 Access Plate 3 MicroSD MicroSDHC Card Figure 3 2 Inserting Removing a MicroSD MicroSDHC Card 3 Without touching the contacts on the card insert or remove the microSD microSDHC card 4 Ins...

Страница 25: ...Device Management 3 3 Inserting Removing the MicroSD MicroSDHC Card 16 RUGGEDCOM i803 Installation Manual 04 2022 C79000 G8976 1005 07 ...

Страница 26: ...OM i803 chassis 1 2 3 1 Ports 1 to 4 2 Port 5 3 Ports 6 to 7 Figure 4 1 Port Assignment Port Type 1 to 4 Copper Ethernet Ports 10 100Base TX 5 Fiber Ethernet Port 100Base FX Ports 6 to 7 Fiber Ethernet Ports 1000Base SX or 1000Base LX or 100Base FX 4 1 Copper Ethernet Ports The RUGGEDCOM i803 supports several 10 100Base TX Ethernet ports that allow connection to standard Category 5 CAT 5 unshielde...

Страница 27: ...mum speed Yellow Solid Link established Yellow Blinking Link activity Link Off No link detected The following is the pin out for the RJ45 male connectors 1 8 Figure 4 2 RJ45 Ethernet Port Pin Configuration Pin Name Description 1 RX Receive Data 2 RX Receive Data 3 TX Transmit Data 4 Reserved Do Not Connect 5 Reserved Do Not Connect 6 TX Transmit Data 7 Reserved Do Not Connect 8 Reserved Do Not Con...

Страница 28: ...Ports 2 1 1 Tx Connector 2 Rx Connector Figure 4 3 LC Port For specifications on the available fiber optic Ethernet ports refer to Fiber Optic Ethernet Port Specifications Page 22 RUGGEDCOM i803 Installation Manual 04 2022 C79000 G8976 1005 07 19 ...

Страница 29: ...Communication Ports 4 2 Fiber Optic Ethernet Ports 20 RUGGEDCOM i803 Installation Manual 04 2022 C79000 G8976 1005 07 ...

Страница 30: ...olation 30 VDC 2 A 60 W 125 VDC 0 24 A 30 W 125 VAC 0 5 A 62 5 W 220 VDC 0 24 A 60 W 250 VAC 0 25 A 62 5 W 1500 Vrms for 1 minute 5 3 Copper Ethernet Port Specifications The following details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM i803 Speed Connector Duplex a Cable Type b Wiring Standard c Maximum Distance d Isolation e 10 100Base TX RJ45 FDX HDX Categ...

Страница 31: ...1300 15 8 0 38 3 0 20 23 SM LC 9 125 1300 15 8 0 38 3 0 20 23 MM LC 62 5 125 1310 19 14 32 14 2 13 a MM Multi Mode SM Single Mode Fixed Gigabit Transceivers Mode a Connector Type Cable Type μm Tx λ typ nm Tx min dBm Tx max dBm Rx Sensitivity dBm Rx Saturation dBm Distance typ km Power Budget dB MM LC 62 5 125 850 9 5 4 0 20 0 0 0 4 10 5 SM LC 9 125 1310 9 5 3 0 21 3 0 10 11 5 a MM Multi Mode SM Si...

Страница 32: ... Protection IP40 1 mm or 0 04 in objects Enclosure Cast Aluminum Enclosure 5 7 Dimension Drawings Note All dimensions are in millimeters unless otherwise stated 134 5 117 5 56 5 99 5 95 3 77 5 11 7 6 3 22 84 97 4 112 3 Figure 5 1 Overall Dimensions RUGGEDCOM i803 Installation Manual 04 2022 C79000 G8976 1005 07 23 ...

Страница 33: ...Technical Specifications 5 7 Dimension Drawings 24 RUGGEDCOM i803 Installation Manual 04 2022 C79000 G8976 1005 07 ...

Страница 34: ...2 2 No 62368 1 14 Information Technology Equipment Safety Part 1 General Requirements CAN CSA C22 2 No 0 M91 General Requirements Canadian Electrical Code Part II CAN CSA C22 2 No 14 05 Industrial Control Equipment CAN CSA C22 2 No 142 M1987 Process Control Equipment Industrial Products CAN CSA C22 2 No 213 M1987 Non Incendive Electrical Equipment for Use in Class I Division 2 Hazardous Locations ...

Страница 35: ...en view 109794217 6 1 2 ATEX IEC Ex This device meets the requirements of the following ATEX IEC Ex standards IEC EN 60079 15 2005 Electrical Apparatus for Explosive Gas Atmospheres Part 15 Construction Test and Marking of Type of Protection N Electrical Apparatus It is specifically approved for use in hazardous locations defined as EEx nC IIC T4 Ex II 3 G 12 24 VDC 2A Class III 6 1 3 European Uni...

Страница 36: ...ide reasonable protection against harmful interference when the equipment is operated in a commercial environment This device generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in ...

Страница 37: ...belling Electromagnetic Compatibility Notice 2008 made under Section 182 of the Radiocommunications Act 1992 Radiocommunications Compliance Labelling Electromagnetic Radiation Notice 2003 made under Section 182 of the Radiocommunications Act 1992 Telecommunications Labelling Customer Equipment and Customer Cabling Notice 2001 made under Section 407 of the Telecommunication Act 1997 The device is m...

Страница 38: ...osure Air 8 kV IEC 61000 4 3 Radiated RFI Enclosure ports 20 V m Signal ports 4 kV 5 kHz IEC 61000 4 4 Burst Fast Transient DC Power ports 4 kV 5 kHz Signal ports 1 kV line to earth IEC 61000 4 5 Surge DC Power ports 0 5 kV line to earth line Signal ports DC Power ports IEC 61000 4 6 Induced Conducted RFI Earth ground ports 10 V IEC 61000 4 8 Magnetic Field Enclosure ports 30 A m IEC 61000 4 29 Vo...

Страница 39: ...gnal ports 2 5 kV common mode 1MHz Oscillatory DC Power ports 2 5 kV common 1 kV differential mode 1MHz Environmental Type Tests Test Description Test Levels IEC 60068 2 1 Cold Temperature Test Ad 40 C 40 F 16 Hours IEC 60068 2 2 Dry Heat Test Bd 85 C 185 F 16 Hours IEC 60068 2 30 Humidity Damp Heat Cyclic Test Db 95 non condensing 55 C 131 F 6 cycles IEC 60068 2 6 Vibration 1 g 10 500 Hz IEC 6006...

Страница 40: ...dustry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens Canada Ltd Digital Industries Process Automation 300 Applewood Crescent Concord Ontario L4K 4E5 Canada 2022 Siemens Canada Ltd Subject to change ...

Отзывы: