Страница 1: ...3964 R RK512 Driver 1 System Configuration 3 2 Selection of External Device 4 3 Example of Communication Setting 5 4 Setup Items 11 5 Cable Diagram 16 6 Supported Device 18 7 Device Code and Address Code 19 8 Error Messages 20 ...

Страница 2: ... External Device Select a model series of External Device to be connected and connection method 2 Selection of External Device page 4 3 Example of Communication Settings This section shows setting examples for communicating between the Display and the External Device 3 Example of Communication Setting page 5 4 Setup Items This section describes communication setup items on the Display Set communic...

Страница 3: ... CPU312IFM CPU313 CPU314 CPU314IFM CPU315 CPU315 2 DP CPU316 CPU316 2 DP CPU318 2 CP341 RS232C RS232C Setting Example 1 page 5 Cable Diagram 1 page 16 CP341 RS422 485 RS422 485 4wire Setting Example 2 page 8 Cable Diagram 2 page 17 SIMATIC S7 400 Series CPU412 1 CPU412 2 DP CPU413 1 CPU413 2 DP CPU414 1 CPU414 2 DP CPU414 3 DP CPU416 1 CPU416 2 DP CPU416 3 DP CPU417 4 CP441 2 RS232C Setting Exampl...

Страница 4: ...onfiguration 1 System Configuration page 3 Use System Area Check this option when you synchronize the system data area of the Display and the device memory of the External Device When synchronized you can use the ladder program of the External Device to switch the display or display the window on the Display Cf GP Pro EX Reference Manual Appendix 1 4 LS Area only for direct access method This can ...

Страница 5: ...ng of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of External Device you want to set from Device Specific Settings of Device PLC Settings When Allowable No of Device PLCs is multiple you can click from Device Specific Settings of Device PLC Settings to ad...

Страница 6: ... drop the using power unit in the rack 7 Similarly drag drop the using CPU unit 8 When using CPUxxx xDP the Properties PROFIBUS interface DP dialog box is displayed In that case click Cancel and close the dialog box 9 Similarly drag drop the using link unit 10 Double click the CPU unit dropped in the rack 11 When the MPI port setting dialog box is displayed click Properties 12 Click Properties as ...

Страница 7: ...is already registered by the previous operation 20 To enable the communication between the External Device and the Display click the Parameter button 21 The Parameter window is displayed Select RK512 from the Protocol list box and double click the Protocol image in the window 22 When the Protocol dialog box is displayed set in the RK 512 tab as below 23 When you finish setting click OK and close t...

Страница 8: ...lect Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of External Device you want to set from Device Specific Settings of Device PLC Settings When Allowable No of Device PLCs is multiple you can click from Device Specific Settings of Device PLC Settings to add External Device which is available to set ...

Страница 9: ... rack 7 Similarly drag drop the using CPU unit 8 When using CPUxxx xDP the Properties PROFIBUS interface DP dialog box is displayed In that case click Cancel and close the dialog box 9 Similarly drag drop the using link unit 10 Double click the CPU unit dropped in the rack 11 When the MPI port setting dialog box is displayed click Properties 12 Click Properties as MPI 1 187 5 Kbps is selected as d...

Страница 10: ...communication between the External Device and the Display click the Parameter button 21 The Parameter window is displayed Select RK512 from the Protocol list box and double click the Protocol image in the window 22 When the Protocol dialog box is displayed set in the RK 512 tab as below 23 When connecting CP341 CP441 with RS422 485 double click the Interface tab and select None in Initial State of...

Страница 11: ...pace Setup Items Setup Description SIO Type Select the SIO type to communicate with the External Device Speed Select speed between the External Device and the Display Data Length Select data length Parity Select how to check parity Stop Bit Select stop bit length Flow Control Select the communication control method to prevent overflow of transmission and reception data Timeout Use an integer from ...

Страница 12: ...ic Settings of Device PLC Settings to add the External Device which is available to set Wait To Send Use an integer from 0 to 255 to enter standby time ms for the Display from receiving packets to transmitting next commands RI VCC Switch the 9th pin setting when you select RS232C for SIO type Setup Items Setup Description Block Check BCC Check to enable the check sum Device Names Select whether th...

Страница 13: ...lect the SIO type to communicate with the External Device Speed Select speed between the External Device and the Display Data Length Select data length Parity Select how to check parity Stop Bit Select stop bit length Flow Control Select the communication control method to prevent overflow of transmission and reception data Timeout Use an integer from 1 to 127 to enter the time s for which the Dis...

Страница 14: ...s from Peripheral Settings Touch the External Device you want to set from the displayed list and touch Device Settings Setup Items Setup Description Device PLC Name Select the External Device for device setting Device name is a title of External Device set with GP Pro EX Initial value PLC1 Block Check BCC Select Enable to enable the check sum ...

Страница 15: ...ion To display the setting screen touch Device PLC Settings from Peripheral Settings Touch the External Device you want to set from the displayed list and touch Option Setup Items Setup Description RI VCC You can switch RI VCC of the 9th pin when you select RS232C for SIO type ...

Страница 16: ...class grounded Please refer to the manual of the External Device for more details SG and FG are connected inside the Display When connecting SG to the External Device design the system not to form short circuit loop Cable Diagram 1 Display Connection Port Cable Remarks GP COM1 Your own cable The cable length must be 15m or less SG RS RTS 5 7 CS CTS 8 RD RXD 2 SD TXD 3 ER DTR 4 DR DSR 6 SG RS RTS 5...

Страница 17: ...mend that the termination resistance should be attached when using the cable in 50m or more length We recommend that the termination resistance should be attached when using the cable in 50m or more length 9 2 11 4 8 TX B RX B RX A TX A GND SHIELD 1 2 3 7 5 SG RDA SDA SDB RDB 6 9 8 4 CSB CSA ERA ERB Pin Signal name Pin Signal name Display D sub 9 pin socket External Device D sub 15 pin plug Shield...

Страница 18: ... of the External Device first Change only the target bit address among the word data once read and write the word data to the External Device Note that the correct data may not be written if you change the word address value in the ladder program while the Display reads the data of the External Device and writes it to the External Device Input I000 0 I127 7 E000 0 E127 7 IW000 IW126 EW000 EW126 2 ...

Страница 19: ...ss type in data displays Device Word Address Device Code HEX Address Code English German Data Block DB DB 0000 Data Block No x 0x10000 Value of word address divided by 2 Input I E 0080 Value of word address divided by 2 Output Q A 0081 Value of word address divided by 2 Internal Marker M M 0082 Value of word address divided by 2 Timer T T 0060 Word Address Counter C Z 0061 Word Address ...

Страница 20: ... No Device Name Name of the External Device where error occurs Device name is a title of the External Device set with GP Pro EX Initial value PLC1 Error Message Displays messages related to the error which occurs Error Occurrence Area Displays IP address or device address of the External Device where error occurs or error codes received from the External Device Received error codes are displayed s...