background image

Operating instructions

Landis & Staefa REV15…

REV15… - the temperature controller that allows you to set the ideal room temperature at the time you want. There
are several switching patterns available that can be set to suit your specific needs. You can either rely on the
factory settings or make settings taillored to your personal needs.

Auto

Run

°C

Day

A1

A2

A3

A4

A5

A6

Setting slider

Changing the

setting values

Operation

Weekly mode with
3 heating periods (A 1-5) /
1 heating period (B 6-7)

Continuous
normal temperature

Continuous
economy temperature

Standby
with frost protection

Operating mode
selector

Change
between normal and
economy mode up to the
next switching point

Warmer/colder setting
valid up to the next
switching point
(increments of 0.2 ºC,
± 4 ºC max.)

Switching pattern

with time cursor

Display

24-hour mode A
with 3 heating periods

24-hour mode B
with 1 heating period

Settings

Normal temperature

Economy temperature

Holiday period

Weekday (1=Monday / 7=Sunday)

Room temperature (measured)

Time of day

Remote operation active
(if connected)

Standby

Normal temperature

Heating on

Economy temperature

Holiday mode

Replace batteries

Auto A/B

1.5V 'AA'

1.5V 'AA'

Time

Operating mode

Auto

Run

1

2

3

4

5

6

7

0

6

12

18

24

A

B

B1

B2

Day

Weekday

Switching times A1... A6

A1

A2

A3

A4

A5

A6

B1

B2

Switching times B1... B2

A

B

Current 24-hour mode

A

B

2225Z11E

Commissioning with quick startup

The controller is supplied with factory-set switching patterns, switching times and temperatures. To commission it,
proceed as follows:

1.5V 'AA'

1.5V 'AA'

Remove the black transit tabs from the two batteries. Check to see if the battery holder is in its correct
position. The controller switches itself on.

Move the setting slider to this position. Press buttons 

 to set the correct time of day.

Day

Move the setting slider to this position. Press buttons 

 to set the correct weekday.

(1 = Monday…7 = Sunday).

Auto

Run

Move the setting slider back to position on the right, because only that position allows you to close the
cover.
Select the required operating mode with the operating mode selector.

Fold up operating instructions again, place them back into the cover and close the cover again.

Do you want to use automatic operation?

If that is the case, set the operating mode
selector to one of the following positions:

Auto A/B

You use the weekly setting with automatic
changeover
 from three heating periods on
weekdays (A 1-5) to one heating period on
weekends (B 6-7).

A

You use the 24-hour setting A with three
heating periods.

B

You use the 24-hour setting B with one
heating period.

The display shows the respective letter A or B.

Do you require continuous normal
temperature?

Move the operating mode selector to «Normal
temperature». This ensures continuous
heating to the normal temperature. The
display shows 

.

Do you require continuous economy
temperature?

Move the operating mode selector to
«Economy temperature». This ensures
continuous heating to the economy
temperature. The display shows 

.

Do you require continuous standby with frost
protection?

Move the operating mode selector to
«Standby». In that case, heating is provided
only when the room temperature falls below
the preset frost protection limit (5 °C). The

display shows 

.

Do you feel too warm or too cold?

°C

By pressing these buttons, you increase or
decrease the actual room temperature in
increments of 0.2 °C by a maximum of 

±

 4°C.

The display first shows the newly selected
temperature and then the actual value again.
These changes are valid only up to the
next switching point.
 

If, as a result of the

factory settings, you always feel either too
warm or too cold, you should readjust the
temperature 

 or 

 to suit your needs.

Отзывы: