9/16
Siemens Building Technologies
Room Temperature Controller REV23RF16A/SET
CE1N2269en
HVAC Products
09.10.2003
The base can be fitted to most types of commercially available recessed conduit boxes
or directly on the wall.
The support supplied with the controller enables the unit to be put on a shelf. It can be
easily fitted to the controller with no need for tools.
Notes
•
The room unit should be located in the main living room (on the wall or free-standing
using the support provided) while giving consideration to the following points:
•
The distance to the receiver should not exceed 20 m or 2 floors
•
The unit should be located such that the sensor is able to capture the room tempera-
ture as accurately as possible, without getting affected by direct solar radiation or
other heat or refrigeration sources (in the case of wall mounting, about 1.5 m above
the floor)
•
The unit should be located such that it can transmit signals with as little interference
as possible. For this reason, the following points should be observed:
−
Do not mount the unit on metal surfaces
−
Not in the vicinity of electrical cables and equipment such as PCs, TV sets, mi-
crowave appliances, etc.
−
Not in the vicinity of large metal structures or construction elements with fine
metal meshes like special glass or special concrete
•
In the case of wall mounting, ensure that there is sufficient clearance for removing the
controller from its base, and for replacing it
min.
10 cm
22
61
Z03
•
The receiver and switching unit should preferably be mounted near the controlled
device
•
The unit should be located such that it can receive signals with as little interference
as possible. For this reason, the following points should be observed (same as with
the transmitter):
−
Not in control panels
−
Not on metal surfaces
−
Not in the vicinity of electrical cables and equipment such as PCs, TV sets, mi-
crowave appliances, etc.
−
Not in the vicinity of large metal structures or construction elements with fine
metal meshes like special glass or special concrete
•
The location where the unit is mounted should be dry and free from splash water
•
The unit can be fitted to most commercially available recessed conduit boxes or di-
rectly on the wall
•
First, fit the base. Then, engage the controller from the top. The base can be fitted to
most commercially available recessed conduit boxes or directly on the wall
Base
Support
Planning
Controller /
transmitter REV23RF
Wall mounting
Planning
Receiver
REV-R.02/16A
Wall mounting of
controller / transmitter
REV23RF