1/4
Operating Instructions
CB1B1425en_01 / 2014-11-26
Siemens Building Technologies
s
Operating Instructions
RDE100.1RFS
The RDE100.1RFS consists of a wireless room thermostat RDE100.1RF and an RCR100RF receiver.
The units allow you to set the ideal room temperature at the time you want.
There are several switching patterns available that can be set to meet your individual needs.
RDE100.1RF
1 Display
Indicates that batteries
need to be replaced
Time of day
Frost protection (heating)
active
Morning: 12-hour format
Afternoon: 12-hour format
Auto Timer mode
Confirmation
View and set Auto Timer
F
Room temperature in
degrees Fahrenheit
Comfort mode
C
Room temperature in
degrees Celsius
Economy mode
Button lock activated
Escape
Room temperature,
setpoint, etc.
External input enabled
Display of zone
(default = 1)
Permanent setpoint setting
Heating On
Weekday and time of day
setting
Weekday 1 = Monday
Weekday 7 = Sunday
Holiday mode setting
Timer bar
Current room temperature
2 Change operating mode
3 Set
4 Ok
5 Decrease value
6 Increase value
7 Battery holder
RCR100RF
8 Indication of data transmission and operating state (LED)
9 Initialization of wireless communication with transmitter
(LEARN button)
Do you want to set the time of day and the weekday?
Set
Ok
+
–
Mode
Proceed as follows:
·
Press
Set
and select
·
Press
Ok
and the time of day flashes for setting
·
Press
+
or
–
to adjust the time of day
·
Press
Ok
to confirm
·
The weekday flashes; press
+
or
–
to select the desired day
·
Press
Ok
to save the setting
·
Press
Mode
to exit or wait for the program to exit automatically