Troubleshooting and tips
A26361-K412-Z107-3-7619
41
The floppy disk cannot be read or written
Ê
Check whether the write protection of the floppy disk is activated.
Ê
In the
BIOS Setup
check the entry for the floppy disk drive.
Ê
Check in the
BIOS Setup
whether the diskette drive controller and write
permission are enabled (see the Technical Manual for the system board).
Ê
Check that the cables of the floppy disk drive are properly connected (refer to
chapter "
").
Time and/or date is not correct
Ê
Set the time and/or date in the operating system or in the
BIOS Setup
.
i
If the time and date are repeatedly wrong when you switch on your
server, the battery is flat. Change the lithium battery as described in the
Technical Manual of the system board.
The system cannot be started up
You have probably received one of the following error messages:
Invalid configuration information
Invalid EISA configuration storage
If you receive one of these messages after system startup, the configuration
information for your EISA system has been deleted. In this case you must restore
the EISA configuration. There are two possibilities to proceed: You can either
repeat the configuration procedure in its entirety (see user manual for EISA
configuration), or better still, you can reload the configuration data (SCI file) that
you saved on floppy disk back onto your system. This possibility is described
below.