background image

  6

P/S

Upgrade Path

P/S

560

R
C
C

565

1 2

3

R
C
C

P/S

VMEbus

Local I/O

575

A

5
0
5

6
8
6
0

VME Base

Bases must be within
three feet of each other and
connected by a #8 copper
ground strap.

575

B

5
0
5

6
8
6
0

Series 505 Base

NOTE: No remote bases can be connected on the RS-485 link between the 575 and the PPX:505–6860.

Remote Series 500/505
Bases with RF RBCs

4

#8 copper
ground strap

Figure 3

Upgrading an RF-Based 560/565/560T/565P System to a 575

Содержание PPX:505–6860 RS-485/RF I/O

Страница 1: ...al media and greater remote distance Organization of Instructions Compatibility Issues Installation Procedure Upgrading from a 560 565 system to a 545 555 Upgrading from a 560 565 system to a 575 Related Manuals The following manuals contain information related to the installation of the PPX 505 6860 converter and cables SIMATIC 505 Redundant I O System Manual PPX 505 8125 x SIMATIC 545 555 System...

Страница 2: ...102 PPX 575 2102 PPX 575 2103 Compatibility with Power Supplies The PPX 505 6860 RS 485 RF converter can be powered by the following supplies PPX 505 6660 115 230 VAC PPX 505 6660A 115 230 VAC dual media compatible PPX 505 6663 24 VDC dual media compatible Compatibility with Remote Bases The PPX 505 6860 RS 485 RF converter is compatible with bases controlled by the following Remote Base Controlle...

Страница 3: ...ects from the 545 555 575 CPU to the new PPX 505 6860 RS 485 I O channel converter is shown in Table 1 This is different from the normal connections for an RS 485 I O channel in that a cable with two twisted shielded pairs with 9 pin subminiature male D connectors at each end is required instead of the single pair cable that is normally used Pair like named signals 3 and 8 and 4 and 9 The suggeste...

Страница 4: ...nformation on installation and operation of the 575 However using multiple CPUs may require significant program modifications in order to divide the 565 program and redistribute the program among the 575 CPUs 3 Re number your bases between 1 and 15 so that no two bases have the same number Base number 0 is the local base where the CPU resides and may be used for additional 505 modules if desired 4...

Страница 5: ...555 Series 505 I O 4 8 or 16 slots Local I O Upgrade Path P S 560 R C C 565 1 2 3 R C C 545 or 5 0 5 6 8 6 0 Coax Series 500 505 bases with RF RBCs NOTE No remote bases can be connected on the RS 485 link between the 545 555 and the PPX 505 6860 Figure 2 Upgrading an RF Based 560 565 560T 565P System to a 545 555 ...

Страница 6: ...ree feet of each other and connected by a 8 copper ground strap 575 B 5 0 5 6 8 6 0 Series 505 Base NOTE No remote bases can be connected on the RS 485 link between the 575 and the PPX 505 6860 Remote Series 500 505 Bases with RF RBCs 4 8 copper ground strap Figure 3 Upgrading an RF Based 560 565 560T 565P System to a 575 ...

Отзывы: