Startup
Nur für den internen Gebrauch
P31003-E8400-A100-3-7620
3-4
Service Manual
Telephone Tests
3.6
Telephone Tests
Accessing the Telephone Test
The telephone test is started by pressing the "service key" and entering the "code number".
●
Tests run for approx. 10 s. These are followed by a timeout.
●
Tests can be stopped at any time by pressing the pound key
.
optiPoint 500 Models with Display (economy, basic, standard and advance)
●
You can browse and display individual tests in the Service menu.
●
Display individual call numbers
●
Activate LEDs and calls.
●
Display showing if power supply is sufficient
–
if sufficient power is being supplied, a light grey pixel pattern is visible
Code
number
Menu text
Action after pressing OK
91
LED
Start the LED test
92
Screen
Start the screen tests
93
Keys
Start the key test
94
Audio
Go to the audio test/submenu
941 Speaker
Test the speaker volume (7 levels)
942 Handset
Test the handset volume (7 levels)
943 Ringer volume
Change the ringer volume (7 levels)
944 Ringer pitch
Change the ringer pitch (7 levels)
945 Alerting tone
Change the volume of the alerting tone (7 levels)
946 Speakerphone mode
Handsfree function (3 levels):
normal, loud, noisy room
940 Back
Return to the audio test
95
Asset ID
Display the asset ID
96
Software version
Display the telephone SW version
97
Feeding range
Start the feeding range test
90
Back
Return to the telephone test
Table 3-1
Telephone test for HiPath 4000/Hicom 300 H
Содержание OPTIPOINT 500
Страница 5: ...P31003 E8400 A100 3 7620 Service Manual 0 3 Index Z 1 ...
Страница 6: ...P31003 E8400 A100 3 7620 0 4 Service Manual ...
Страница 8: ...P31003 E8400 A100 3 7620 0 2 Service Manual ...
Страница 10: ...P31003 E8400 A100 3 7620 0 2 Service Manual ...
Страница 36: ...Product Description P31003 E8400 A100 3 7620 2 22 Service Manual Technical Data ...
Страница 104: ...IP Adapter Nur für den internen Gebrauch P31003 E8400 A100 3 7620 7 40 Service Manual Configuration Examples ...
Страница 106: ...Troubleshooting Nur für den internen Gebrauch P31003 E8400 A100 3 7620 8 2 Service Manual Reboot ...
Страница 116: ...Ordering Information Nur für den internen Gebrauch P31003 E8400 A100 3 7620 9 10 Service Manual Intranet Addresses ...