Mounting
4.7 Connecting the motor
BA 2320
Operating Instructions, 02/2015, 70000004023775
37
For metal or plastic cable glands, please use the following tightening torques for direct
mounting. The O-ring cross-section is 2 mm.
Table 4- 8
Tightening torque for cable gland
Thread size
Tightening torque ±10 %
Thread size
Tightening torque ±10 %
Metal
Plastic
Metal
Plastic
[Nm]
[Nm]
[Nm]
[Nm]
M12 x 1.5
8
4
M32 x 1.5
18
6
M16 x 1.5
10
M40 x 1.5
M20 x 1.5
12
M50 x 1.5
20
M25 x 1.5
M63 x 1.5
4.7.9
Forced ventilation (optional)
4.7.9.1
General information for commissioning of forced ventilation
Please note the direction of rotation. It is indicated with an arrow on the forced ventilation
unit.
Connect the forced ventilation according to the applicable circuit diagram.
Before commissioning the motor, check that the forced ventilation is working properly.
The forced ventilation must be switched on during motor operation.
After the motor has been switched off, the forced ventilation must continue to run, depending
on the temperature.