Milltronics WD600
Operating Instructions, 09/2016, A5E38964753_A
B
27
Technical data
8
8.1
Specifications
Accuracy
± 0.5% or better of totalization over 25 to 100% operating range
Accuracy subject to: On factory approved installations the belt scale systems totalized weight will be
within the specified accuracy when compared to a known weighed material test sample. The test
rate must be within the specified range of the design capacity and held constant for the duration of
the test. The minimum material test sample must be equivalent to a sample obtained at the test
flow rate for three revolutions of the belt or at least ten minutes running time, whichever is greater.
Load Cell
construction
nickel plated alloy steel or 17-4 PH (1.4568)
stainless steel
degree of protection
IP66 rated (nickel plated)
IP68 rated (stainless steel)
excitation
10 V DC nominal, 15 V DC maximum
output
2 mV/V excitation at rated load cell capacity
non-linearity
0.02% of rated output
hysteresis
0.02% of rated output
non-repeatability
0.01% of rated output
capacity
nickel plated maximum ranges: 10, 15, 20, 30, 50
kg
stainless steel maximum ranges: 6, 12, 30 kg
overload
150% of rated capacity
ultimate 300% of rated capacity
temperature
–40 to +65 °C (– 40 to +150 °F) operating range
–10 to +40 °C (–15 to +105 °F) compensated
Belt width
300 to 1200 mm (12 to 48")
Refer to Outline dimensions (Page 29)
Содержание Milltronics WD600
Страница 1: ...Operating Instructions Milltronics WD600 09 2016 Edition Belt Scales ...
Страница 8: ...Introduction 1 1 The manual 6 Milltronics WD600 Operating Instructions 09 2016 A5E38964753_AB ...
Страница 10: ...Safety notes 2 1 General safety instructions 8 Milltronics WD600 Operating Instructions 09 2016 A5E38964753_AB ...
Страница 24: ...Connecting 5 1 Belt scale wiring 22 Milltronics WD600 Operating Instructions 09 2016 A5E38964753_AB ...
Страница 32: ...Dimension drawings 9 1 Outline dimensions 30 Milltronics WD600 Operating Instructions 09 2016 A5E38964753_AB ...
Страница 33: ......