![Siemens MICROMASTER 430 Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/siemens/micromaster-430/micromaster-430_operating-instructions-manual_377234047.webp)
3 Commissioning
Issue 10/06
MICROMASTER 430 Operating Instructions
46
6SE6400-5AE00-0BP0
3.1.1
Standard settings for the terminals
See Figure 3-2.
3.1.2 Analogue
inputs
Analogue input 1 (AIN1) can be used with:
0 - 10 V, 0 - 20 mA and -10 V to +10 V
Analogue input 2 (AIN2) can be used with:
0 - 10 V and 0 - 20 mA
The analog input circuit can be alternatively configured to provide additional digital
inputs (DIN7 & DIN8) as shown:
1
2
10
11
DIN8
1
2
3
4
DIN7
Figure 3-2
Configuration of the analogue input as a digital input
When an analogue input is configured as a digital input the threshold values are as
follows:
1.75 V DC = OFF
3.70 V DC = ON
Terminal 9 (24 V) can also be used to drive the analog inputs when used as digital
inputs. Terminals 2 and 28 (0 V) must be linked together.
http://nicontrols.com
Содержание MICROMASTER 430
Страница 43: ...2 Installation Issue 10 06 MICROMASTER 430 Operating Instructions 42 6SE6400 5AE00 0BP0 http nicontrols com ...
Страница 61: ...3 Commissioning Issue 10 06 MICROMASTER 430 Operating Instructions 60 6SE6400 5AE00 0BP0 http nicontrols com ...
Страница 89: ...8 Options Issue 10 06 MICROMASTER 430 Operating Instructions 88 6SE6400 5AE00 0BP0 http nicontrols com ...
Страница 115: ...Index Issue 10 06 MICROMASTER 430 Operating Instructions 114 6SE6400 5AE00 0BP0 http nicontrols com ...
Страница 117: ...MICROMASTER 430 Operating Instructions 116 6SE6400 5AE00 0BP0 http nicontrols com ...
Страница 118: ...MICROMASTER 430 Operating Instructions 6SE6400 5AE00 0BP0 117 http nicontrols com ...