AT command interface
Version 8 dated 15.03.00
134
Siemens Information and Communication Products
AT^SSET
Set some unsolicited result codes
Test command
AT^SSET=?
Response
OK
Read command
AT^SSET?
Response
^SSET: <SIM ready>
Parameter
<SIM ready>
0 or 1 representing the setting of unsolicited result code presentation.
Set command
AT^SSET = [<SIM
ready>],[<bbnc>]
Response
Set the presentation of unsolicited result code.
Parameter
<SIM ready>
Presentation of unsolicited result code ^SSIM READY:
0 Unsolicited result codes off
1 Unsolicited result codes on
<bbnc>
BREAK is sent before NO CARRIER on dropped data call:
0 BREAK not sent
1 BREAK sent
Note:
The current value of the parameters can be stored using the command
. On power up or with the ATZ command the value ist read from the EEPROM.
The factory default value (0) is set with command
AT&F Set all current parameters to manufacturer
Reference
Unsolicited result code
Unsolicited result code sent after finish reading of SMS and phone books from SIM:
^SSIM READY