AT command interface
Version 8 dated 15.03.00
45
Siemens Information and Communication Products
AT&V
Display current configuration
Execute command
AT&V[<n>]
Response
TA returns the current parameter setting.
ACTIVE PROFILE :
E1 L0 M0 Q0 V1 X4;
S0:1 S2:43 S3:13 S4:10 S5:8 S6:2 S7:60 S8:2 S10:15 S12:10 S13:60 S1:0
+CBST: 7,0,1
+CRLP: 61,61,48,6,1,3
+CRC: 0
+CR: 1
+FCLASS: 0
+IFC: 2,2
+ICF: 3,3
+DR: 1
+CMGF: 0
+CSDH: 1
+CNMI: 2,1,0,0,0
+ILRR: 0
+IPR: 19200
+DS: 0,0,512,6
+CMEE: 2
^SMGO: 0
+CSMS: 0
^SACM: 0
^SCKS: 0
+CREG: 2
+CCUG: 0,0,0
+CLIP: 0
+COLP: 0
+CCWA: 0
+CAOC: 1
+CLIR: 0
+COPS: 0
OK
Parameter
<n>
0
profile number
Reference
Note
AT&W
Store current parameter to user defined profile
Execute command
AT&W[<n>]
Response
TA stores the current parameter setting in the user-defined profile.
Note1:
the user defined profile is stored in non-volatile memory.
OK
Parameter
<n>
0
profile number to store to
Reference
Note