AT command interface
Version 8 dated 15.03.00
133
Siemens Information and Communication Products
AT^MONI
Monitor idle mode and dedicated mode
Test command
AT^MONI[=<peri-
od>]
Response
See execute command
Command is broken by any character sent to serial port
Parameter
<period>Display period in seconds
Execute command
AT^MONI
Response
Serving cell I Dedicated channel
chann rs dBm PLMN LAI cell NCC BCC PWR RXlev C1 I chann TS timAdv PWR dBm Q
89 49 -61 023203 3A98 4EAF 0 4 5 -102 41 I 116 7 1 10 -60 2
OK
Parameters
Serving cell:
chann
Channel number
rs
RSSI value (0–63)
dBm
Receiving level in dBm
PLMN
PLMN ID code
LAI
Location area ID
cell Cell
ID
NCC
PLMN colour code
BCC
BS colour code
PWR
Maximal power level used on RACH channel
Rxlev
Minimal receiving level (in dBm) to allow registration
C1
C1 coefficient for base station selection
Dedicated channel:
chann
Channel number
TS
Time slot
timAdv
Timing advice in bits
PWR
Current power level
dBm
Receiving level in dBm
Q
Receiving quality (0–7)
ChMod
Channel coding:
SIGN
signalling only
S FR
speech full rate
S EFR
speech enhanced full rate
D F96
data 9600 Bd
D F48
data 4800 Bd
D F24
data 2400 Bd
Reference
Note