12

Only use genuine spare parts when repair-
ing the appliance.

If the power cord of this appliance is dam-
aged, it must be replaced by the manufac-
turer, the manufacturer's Customer Service
or a similarly qualified person in order to
prevent any risk.

Improper installation is dangerous.

Connect and operate the appliance only in
accordance with the specifications on the
rating plate.

Connect the appliance to a power supply
with alternating current only via a properly
installed socket with earthing.

The protective conductor system of the do-
mestic electrical installation must be prop-
erly installed.

Never equip the appliance with an external
switching device, e.g. a timer or remote
control.

When the appliance is installed, the mains
plug of the power cord must be freely ac-
cessible. If free access is not possible, an
all-pole isolating switch must be installed in
the permanent electrical installation accord-
ing to the conditions of Overvoltage Cat-
egory III and according to the installation
regulations.

When installing the appliance, check that
the power cable is not trapped or dam-
aged.

12.4 Information on the installation situation

¡

Install this appliance in a kitchen cupboard.

12.5 Instructions for the exhaust air pipe

The appliance manufacturer does not provide any war-
ranty for faults attributable to the pipeline.

¡

Use a short, straight exhaust air pipe with as large a
pipe diameter as possible.

¡

Long, rough exhaust air pipes, many pipe bends or
small pipe diameters reduce the suction power and
increase the fan noise.

¡

An exhaust air pipe that is made of non-combustible
material.

¡

To prevent condensate from returning, fit the ex-
haust air pipe from the appliance with a 1° gradient.

Round pipes

Use round pipes with an inner diameter of 150 mm (re-
commended) or at least 120 mm.

Flat ducts

Use flat ducts with an inner cross-section that corres-
ponds to the diameter of the round pipes:

¡

Diameter of 150 mm corresponds to ap-
prox. 177 cm².

¡

Diameter of 120 mm corresponds to ap-
prox. 113 cm².

¡

Use sealing strips for different pipe diameters.

¡

Do not use any flat ducts with sharp bends.

12.6 Instructions for the electrical
connection

In order to be able to safely connect the appliance to
the electrical system, follow these instructions.

WARNING ‒ Risk of electric shock!

It must always be possible to disconnect the appliance
from the electricity supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed.

The mains plug for the mains power cable must be
easily accessible after the appliance is installed.

If this is not possible, an all-pole isolating switch
must be integrated into the permanent electrical in-
stallation according to the conditions of overvoltage
category III and according to the installation regula-
tions.

The permanent electrical installation must only be
wired by a professional electrician. We recommend
installing a residual-current circuit breaker (RCCB)
in the appliance's power supply circuit.

Sharp-edged components inside the appliance may
damage the connecting cable.

Do not kink or trap the connecting cable.

¡

The connection data can be found on the rating
plate inside the appliance.

¡

To see the rating plate, remove the grease filter.

¡

The connecting cable is approx. 1.30 m long.

¡

This appliance complies with the EC interference
suppression regulations.

¡

The appliance corresponds to protection class 1.
Therefore, only use the appliance with a protective
earth connection.

¡

Do not connect the appliance to the power supply
during installation.

¡

Ensure that the protection against contact is guaran-
teed during installation.

12.7 General information

Follow these general instructions during the installation.

¡

For the installation, observe the currently valid build-
ing regulations and the regulations of the local elec-
tricity and gas suppliers.

¡

When discharging the exhaust air, the official and
legal regulations, such as the regional building
code., must be observed.

¡

The width of the extractor hood must correspond at
least with the width of the hob.

¡

To optimally detect the cooking vapours, install the
appliance in the middle of the hob.

¡

In order to freely access the appliance for servicing,
select an easy-to-reach installation site.

¡

The surfaces of the appliance are sensitive. Avoid
damaging them during installation.

Содержание LI67RA561

Страница 1: ...B LI67SA561S LI97RA561 LI67RA561 en User manual and installation instructions Register your product on My Siemens and discover exclusive ser vices and offers siemens home bsh group com welcome The future moving in Siemens Home Appliances ...

Страница 2: ...ldren must not play with the appliance Children must not perform cleaning or user maintenance unless they are at least 15 years old and are being supervised Keep children under the age of 8 years away from the appliance and power cable 1 4 Safe use WARNING Risk of suffocation Children may put packaging material over their heads or wrap themselves up in it and suffocate Keep packaging material away...

Страница 3: ...at the same time generates a great deal of heat A ventilation appliance installed above the cooker may be come damaged or catch fire Only operate the gas hobs with cookware on them Select the highest fan setting Never operate two gas hobs simultan eously on the highest flame for longer than 15 minutes Two gas hobs correspond to one large burner Never operate large burners of more than 5 kW with th...

Страница 4: ...stress on the design elements they may break off Do not pull design elements Do not place objects on the design elements or hang objects from them 3 Environmental protection and saving energy Help protect the environment by using your appliance in a way that conserves resources and by disposing of reusable materials properly 3 1 Disposing of packaging The packaging materials are environmentally co...

Страница 5: ... ex haust gas flue you must obtain the consent of the heating engineer re sponsible If the exhaust air is conveyed through the external wall a tele scopic duct should be used 4 2 Air recirculation mode The air which is drawn in is cleaned by the grease fil ters and an odour filter and conveyed back into the room To bind odours in circulating air mode you must install an odour filter The dif ferent...

Страница 6: ...inutes the appliance automatic ally switches to a lower fan setting 6 5 Switching off intensive mode Press until the required fan setting is reached a Intensive mode is ended early 6 6 Switching on the boost function The boost function is a short term maximum power set ting which can be activated in any fan setting Press a After approx 20 seconds the fan automatically switches back to the fan sett...

Страница 7: ...g the ap pliance while it is hot Only use glass cleaners glass scrapers or stainless steel care products if recommended in the cleaning instructions for the relevant part Wash sponge cloths thoroughly before use 7 2 Cleaning the appliance Clean the appliance as specified This will ensure that the different parts and surfaces of the appliance are not damaged by incorrect cleaning or unsuitable clea...

Страница 8: ... grease filters filter the grease from the cooking va pour Regularly cleaned grease filters guarantee a high level of grease removal WARNING Risk of fire Fatty deposits in the grease filters may catch fire Clean the grease filters regularly Requirement The grease filters have been removed Removing the grease filter Page 7 1 Observe the information regarding the cleaning agents Cleaning products Pa...

Страница 9: ...ct Customer Service you will require the product number E Nr and the production number FD of your appliance The contact details for Customer Service can be found in the enclosed Customer Service directory or on our website 9 1 Product number E Nr and production number FD You can find the product number E Nr and the pro duction number FD on the appliance s rating plate Depending on the model the ra...

Страница 10: ...nd electronic equip ment WEEE The guideline determines the frame work for the return and recycling of used appliances as applicable throughout the EU 12 Installation instructions Observe this information when installing the appliance 12 1 Included with the appliance After unpacking all parts check for any damage in transit and completeness of the delivery Depending on the appliance specifications ...

Страница 11: ...gether the largest specified clearance applies The appliance must be installed with no more than one side directly next to a high sided unit or a wall The distance between the appliance and wall or high sided unit must be at least 50 mm Grease deposits in the grease filter may catch fire Never work with naked flames close to the appliance e g flambéing Do not install the appliance near a heat prod...

Страница 12: ... pipe diameters Do not use any flat ducts with sharp bends 12 6 Instructions for the electrical connection In order to be able to safely connect the appliance to the electrical system follow these instructions WARNING Risk of electric shock It must always be possible to disconnect the appliance from the electricity supply The appliance must only be connected to a protective contact socket that has...

Страница 13: ...ing air set min 600 mm Wall thickness 16 mm or 19 mm Preparing the units Requirement The unit is suitable for the installation Checking the unit Page 13 1 Cover the hob to prevent damage 2 Ensure that the stability of the fitted unit is guaran teed after the cut outs have been made 3 If the cabinet is less than 320 mm deep remove part of the back panel 4 Create the cut out for the pipe connection ...

Страница 14: ...p to the clearance between the appliance and the wall 4 Snap the wall closing strip into the holders 5 Fit the grease filters 6 Establish the pipe connection 7 Establish the electrical connection Note You can conceal the housing of the extractor hood within the upper cabinet In doing so observe the following The intermediate floor must not rest on the housing The front panel must not be secured to...

Страница 15: ...ective caps from the fastening bolts 6 Support the appliance with one hand while carrying out the following steps 7 Push in the fastening bolts using a flat blade screw driver and rotate by 90 until the fastening bolts un clip 8 Push in and turn the fastening bolts gently with your fingers until the fastening bolts springs out of the housing Lift the appliance slightly and pull on the fastening bo...

Страница 16: ...hen GERMANY www siemens home bsh group com Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Road Wolverton Milton Keynes MK12 5PT United Kingdom Manufactured by BSH Hausgeräte GmbH under the trademark licence of Siemens AG ...

Отзывы: