en
General information
12
:
Warning – Risk of electric shock!
Incorrect repairs are dangerous. Repairs may
only be carried out and damaged power
cables replaced by one of our trained after-
sales technicians. If the appliance is defective,
unplug the appliance from the mains or switch
off the circuit breaker in the fuse box. Contact
the after-sales service.
:
Warning – Danger of suffocation!
Packaging material is dangerous to children.
Never allow children to play with packaging
material.
K
General information
General in
formation
Checking the wall
■
The wall must be level, vertical and adequately load-
bearing.
■
The depth of the bore holes must be the same
length as the screws. The wall plugs must have a
secure grip.
■
The enclosed screws and wall plugs are suitable for
solid brickwork. Suitable fasteners must be used for
other structures (e.g. plasterboard, porous concrete,
poroton bricks).
■
The maximum weight of the extractor hood is
40 kg
.
Electrical connection
:
Warning – Risk of electric shock!
Components inside the appliance may have sharp
edges. These may damage the connecting cable. Do
not kink or pinch the connecting cable during
installation.
The required connection information can be found on
the rating plate on the top of the appliance.
Length of the cable: approx. 1.30 m
This appliance complies with the EC interference
suppression regulations.
:
Warning – Risk of electric shock!
It must always be possible to disconnect the appliance
from the power supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed. If the plug can no longer be reached
after installation, an energy-isolating device in the
phases must be provided in the permanent electrical
installation in accordance with the installation
regulations. The permanent electrical installation must
only be wired by a professional electrician. We
recommend installing a residual-current circuit breaker
(RCCB) in the appliance's power supply circuit.
Installation
en
13
5
Installation
Installati
on
Preparing the installation
Caution!
Ensure that there are no electric wires, gas or water
pipes in the area where holes are to be made.
1.
Mark a vertical centre line on the wall from the
ceiling to the lower edge of the extractor hood.
2.
Mark positions for the screws and the contour of the
attachment area.
3.
Drill 8mm Ø holes to a depth of 80mm and press
the wall plugs flush with the wall.
¨
4.
Screw on the fixing bracket for the flue duct.
©
5.
Screw in 2 securing screws with washers to
approx.5mm.
ª
Installation
1.
Attaching and aligning the appliance.
¨
2.
Mark the hole for the safety screw.
©
3.
Remove the appliance once more.
ª
Finishing installation of the appliance
1.
Drill an 8mm Øhole to a depth of 80mm for the
safety screw and press the wall plug flush into the
wall.
¨
2.
First remove the protective foil from the back of the
appliance and, following installation, remove the foil
completely.
3.
Connect the appliance.
©
4.
Screw in the safety screw - and washer - and tighten
all the screws.
ª
[
!
!
$
$
$
$
$
$
$
%
%
&
%
&
$
$
%
&
Содержание LC64PBC50B
Страница 1: ...Extractor hood en Instructions for installation and use ...
Страница 15: ...6 ...