Incorrect repairs are dangerous.

Repairs to the appliance should only be
carried out by trained specialist staff.

Only use genuine spare parts when repair-
ing the appliance.

If the power cord of this appliance is dam-
aged, it must be replaced by trained spe-
cialist staff.

Incorrect installation is dangerous.

Connect and operate the appliance only in
accordance with the specifications on the
rating plate.

Connect the appliance to a power supply
with alternating current only via a properly
installed socket with earthing.

The protective conductor system of the do-
mestic electrical installation must be prop-
erly installed.

Never equip the appliance with an external
switching device, e.g. a timer or remote
control.

When the appliance is installed, the mains
plug of the power cord must be freely ac-
cessible. If free access is not possible, an
all-pole isolating switch must be installed in
the permanent electrical installation accord-
ing to the conditions of Overvoltage Cat-
egory III and according to the installation
regulations.

When installing the appliance, check that
the power cable is not trapped or dam-
aged.

12.5 General information

Follow these general instructions during the installation.

¡

For the installation, observe the currently valid build-
ing regulations and the regulations of the local elec-
tricity and gas suppliers.

¡

When discharging the exhaust air, the official and
legal regulations, such as the regional building
code., must be observed.

¡

In order to freely access the appliance for servicing,
select an easy-to-reach installation site.

¡

The surfaces of the appliance are sensitive. Avoid
damaging them during installation.

12.6 Instructions for the electrical
connection

In order to safely connect the appliance to the elec-
trical system, follow these instructions.

WARNING ‒ Risk of electric shock!

It must always be possible to disconnect the appliance
from the electricity supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed.

The mains plug for the mains power cable must be
easily accessible after the appliance is installed.

If this is not possible, an all-pole isolating switch
must be integrated into the permanent electrical in-
stallation according to the conditions of overvoltage
category III and according to the installation regula-
tions.

The permanent electrical installation must only be
wired by a professional electrician. We recommend
installing a residual-current circuit breaker (RCCB)
in the appliance's power supply circuit.

Sharp-edged components inside the appliance may
damage the connecting cable.

Do not kink or trap the connecting cable.

¡

The connection data can be found on the rating
plate. → 

Page 9

¡

The connecting cable is approx. 1.30 m long.

¡

This appliance complies with the EC interference
suppression regulations.

¡

The appliance corresponds to protection class 1.
You should therefore only use the appliance with a
protective earth connection.

¡

Do not connect the appliance to the power supply
during installation.

¡

Ensure that the protection against contact is guaran-
teed during installation.

12.7 Information on the installation situation

¡

Install this appliance on the kitchen wall.

¡

To install additional special accessory parts, ob-
serve the enclosed installation instructions.

¡

The appliance must be installed with no more than
one side directly next to a high-sided unit or a wall.
The distance between the appliance and wall or
high-sided unit must be at least 50 mm.

¡

The width of the extractor hood must correspond at
least with the width of the hob.

¡

To optimally detect the cooking vapours, install the
appliance in the middle of the hob.

12.8 Instructions for the exhaust air pipe

The appliance manufacturer does not provide any war-
ranty for faults attributable to the pipeline.

¡

Use a short, straight exhaust air pipe with as large a
pipe diameter as possible.

¡

Long, rough exhaust air pipes, many pipe bends or
small pipe diameters reduce the suction power and
increase the fan noise.

¡

Use an exhaust pipe that is made of non-combust-
ible material.

¡

To prevent condensate from returning, fit the ex-
haust pipe with a 1° gradient from the appliance.

Содержание LC64B Series

Страница 1: ...6B LC66B LC94Q LC64Q LC96Q en User manual and installation instructions Register your product on My Siemens and discover exclusive ser vices and offers siemens home bsh group com welcome The future moving in Siemens Home Appliances ...

Страница 2: ...x 2000 m above sea level Do not use the appliance With an external timer 1 3 Restriction on user group This appliance may be used by children aged 8 or over and by people who have reduced physical sensory or mental abilities or inad equate experience and or knowledge provided that they are supervised or have been instructed on how to use the appliance safely and have understood the resulting dange...

Страница 3: ...ouse s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the ap pliance is operated exclusively in circulat ing air mode WARNING Risk of fire Fatty deposits in the grease filters may catch fire Never operate the appliance without a grease filter Clean the grease filters regularly Never work with naked flames close to the applia...

Страница 4: ...ncorrect cleaning damages the surfaces Follow the cleaning instructions Do not use harsh or abrasive detergents Clean stainless steel surfaces in the direction of the finish only Never clean controls with stainless steel cleaners Condensation that flows back in may damage the ap pliance The air extraction duct must be installed with a gradient of at least 1 from the appliance If you put incorrect ...

Страница 5: ...air back into the room If the exhaust air is to be conveyed into a non functioning smoke or ex haust gas flue you must obtain the consent of the heating engineer re sponsible If the exhaust air is conveyed through the external wall a tele scopic duct should be used 4 2 Air recirculation mode The air which is drawn in is cleaned by the grease fil ters and an odour filter and conveyed back into the ...

Страница 6: ...minium parts in the interior of the appliance may cause explosions Never use highly caustic alkaline or highly acidic cleaning agents In particular do not use commer cial or industrial cleaning agents in conjunction with aluminium parts e g grease filter on extractor hoods WARNING Risk of electric shock An ingress of moisture can cause an electric shock Before cleaning pull out the mains plug or s...

Страница 7: ...e recommend cleaning the grease filters every two months WARNING Risk of fire Fatty deposits in the grease filters may catch fire Clean the grease filters regularly Requirement The grease filters have been removed 1 Observe the information regarding the cleaning agents Cleaning products Page 7 2 Soak the grease filter in hot soapy water Use special grease solvent for stubborn dirt You can obtain g...

Страница 8: ...s Fault Cause and troubleshooting The appliance is not working The mains plug of the power cord is not plugged in Connect the appliance to the power supply The circuit breaker in the fuse box has tripped Check the circuit breaker in the fuse box There has been a power cut Check whether the lighting in your kitchen or other appliances are working The LED lighting does not work Different causes are ...

Страница 9: ...an be found in the enclosed Customer Service directory or on our website 10 1 Product number E Nr and production number FD You can find the product number E Nr and the pro duction number FD on the appliance s rating plate Depending on the model the rating plate can be found Inside the appliance remove grease filters for ac cess On top of the appliance Make a note of your appliance s details and th...

Страница 10: ...age in transit and completeness of the delivery 12 2 Safety clearances Comply with the safety clearances for the appliance For Australia and New Zealand the minimum safety clearance above electrical cooktops must be 600 mm 12 3 Appliance dimensions You will find the dimensions of the appliance here ...

Страница 11: ...g space Always ensure adequate fresh air in the room if the appliance is being operated in exhaust air mode at the same time as a room air dependent heat producing appli ance is being operated It is only possible to safely operate the ap pliance if the pressure in the room in which the heating appliance is installed does not drop more than 4 Pa 0 04 mbar below at mospheric pressure This can be ach...

Страница 12: ... appliance and wall or high sided unit must be at least 50 mm The grease deposits in the grease filter may catch fire Never work with naked flames close to the appliance e g flambéing Do not install the appliance near a heat producing appliance for solid fuel e g wood or coal unless a closed non remov able cover is present There must be no fly ing sparks WARNING Risk of injury Components inside th...

Страница 13: ...ontact socket that has been correctly installed The mains plug for the mains power cable must be easily accessible after the appliance is installed If this is not possible an all pole isolating switch must be integrated into the permanent electrical in stallation according to the conditions of overvoltage category III and according to the installation regula tions The permanent electrical installa...

Страница 14: ... enclosed screws and wall plugs are suitable for use with solid brickwork Use suitable fastening parts for other structures e g plasterboard porous concrete poroton bricks Preparing the wall Note Depending on the design holes must be placed differently Before installing pay attention to the design of the extractor hood 1 Ensure that there are no electrical wires gas pipes or water pipes in the are...

Страница 15: ...mend the piping with an exhaust air pipe dia meter of 150 mm Establishing the exhaust air connection exhaust pipe 150 mm diameter 1 Secure the exhaust pipe to the air pipe connector 2 Establish the connection to the exhaust air opening 3 Seal the joints Establishing the exhaust air connection exhaust pipe 120 mm diameter 1 Secure the reducing connector to the air pipe con nector 2 Secure the exhau...

Страница 16: ...he outer flue duct to protect the surface Place the flue duct sections on the appliance 6 Slide the inner flue duct section upwards and at tach it to the left and right hand sides of the retain ing bracket 7 Engage the flue duct section downwards 8 Screw the flue duct section to the sides of the re taining bracket using two screws 9 Use two screws to secure the outer flue duct sec tion to the appl...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...hen GERMANY www siemens home bsh group com Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Road Wolverton Milton Keynes MK12 5PT United Kingdom Manufactured by BSH Hausgeräte GmbH under the trademark licence of Siemens AG ...

Отзывы: