BA 9137 en 12/2015
10.7
Maintenance
Maintenance comprises all measures for preserving the required condition.
Table 16:
Maintenance measures
Measures
Periods
Remarks
The proper function and
measurement accuracy of the
ignition protection system for the
temperature monitoring should be
checked at regular intervals
according to the instructions of the
manufacturer of the ignition
protection device
see instructions of the
manufacturer.
The operator must ensure this.
First oil change after start-up
after approx. 1000 operating hours
or depending on the results of the
oil analysis carried out
Oil analyses
first one after 1000 operating
hours, all subsequent ones
annually
Subsequent oil changes
depending on the oil analysis
results; (without oil analysis: at the
latest after 18 months and/or
10000 operating hours)
Clean the gear unit
as required, at least every 2 years
Clean the air filter
every 3 months
See item
.
Replacing the air filter cartridge
annually or when the air filter is
heavily soiled.
Checking tightness of the foundation
bolts
every 12 weeks
General inspection of the gear unit
every 2 years
Maintenance work on the oil-supply
system
see also operating instructions
oil-supply system.
See also operating instructions
oil-supply system.
Check couplings
every 6 months
See operating instructions
individual components.
DANGER
Electrostatic discharge
Danger to life from ignition of present explosive atmosphere by electrostatic discharge.
The coating must not carry an electrostatic charge.
The operator must ensure that highly effective mechanisms which can set up a charge in the coating
are safely avoided.