Siemens KFV Скачать руководство пользователя страница 4

02.2019

4/18

H47.ELEKS005EN-00

Electromechanical systems

Operating instructions

A-opener 2.1

Introduction

1.1 

Manufacturer and Service

KFV Karl Fliether GmbH & Co. KG 

 

A company of the SIEGENIA GROUP

 

Siemensstraße 10 

 

42551 Velbert 
E-Mail: [email protected] 

1.2 

Target group of this documentation

This documentation is intended for use by end users. 

In order to guarantee the safe use of the A-opener and 

to prevent malfunction or damage, please read these 

operating instructions carefully and completely and ob

-

serve the instructions specified in the chapter "Safety" 

in particular.

1.3 

Intended use

• 

The AS3500/3600 multi-point lock with A-opener 

2.1 is a special lock for locking and unlocking doors 

automatically.

• 

The AS3500/3600 multi-point lock with A-opener 

2.1 is suitable for installation in timber, aluminium, 

steel and PVC entry doors for residential and public 

buildings.

• 

All assembly and electrical installation work must be 

carried out according to our assembly and instal

-

lation instructions. Wiring the unit incorrectly can 

irreparably damage its electronic components.

• 

The AS 3500/3600 multi-point lock with A-opener 

2.1 may only be used

– 

with cylinder locks with free-running catches in 

which the catch can always be freely turned

– 

with cylinder locks with a rigid catch in which 

the catch is locked in a key withdrawal position 

inside the range of –

 

30° to +

 

30°.

• 

The AS3500/3600 multi-point lock with A-opener 

2.1 can be connected to an external access control 

system via a voltage-free contact - switching time: 

min. 1 second.

• 

Use the AS3500/3600 multi-point lock with A-opener 

2.1 only when it is in a technically sound condition. 

Do not modify the unit's components in any way.

• 

Use the AS3500/3600 multi-point lock with A-opener 

2.1 only with original KFV accessories. 

1.3.1 

Locking part and hardware

• 

The use of any additional devices to keep the door 

closed (with the exception of a door closer) is not 

permitted. If a door closer is installed, it must not 

impede operation of the door by children, the elder

-

ly or infirm.

• 

Repair of the AS3500/3600 multi-point lock with 

A-opener 2.1 is not permissible. If the AS3500/3500 

multi-point lock with A-opener 2.1 is damaged, it 

must be replaced by KFV or repaired by a service 

agent authorised by KFV.

• 

Only KFV frame parts with Q adjustment may be 

used.

1.3.2  Transport

• 

Always transport the door leaf in a vertical position.

• 

Do not carry the door by the lever handle or hard

-

ware when transporting it.

1.3.3 

Opening/Closing/Locking

• 

It must be possible to open and close the door easily. 

A protruding latch and /or deadbolt must not impe

-

de the opening and closing of the door.

• 

The locking elements must always engage freely in 

the lock striker of the frame parts.

• 

If the locking elements do not retract easily, adjust 

the penetrations of the frame parts and the AT-piece.

1.4 

Improper use

• 

The AS3500/3600 multi-point lock with A-opener 2.1 

must not be used for escape doors!

• 

The AS3500/3600 multi-point lock with A-opener 

2.1 is not designed to accommodate changes to its 

shape or seal which arise as a result of differences in 

temperature or changes to the building.

• 

The AS3500/3600 multi-point lock with A-opener 2.1 

must not be used in doors for wet rooms or rooms 

in which the air contains aggressive or corrosive 

components.

• 

Foreign objects and/or materials which impede or 

prevent proper use must not be placed within the 

opening range, the locking system or the striker 

plates. 

• 

If the AS 3500/3600 has been locked via the profi

-

le cylinder, the main deadbolt is extended and the 

lever handle is therefore blocked (child-proof lock). 

An electric opening process may not be carried out 

in this case.

• 

Do not interfere with and/or make any modifications 

to the multi-point lock. 

• 

Locking elements must not be misused to hold the 

door open. 

• 

Movable or adjustable locking pieces (e.g. deadbolt, 

latch) must not be painted over.

1.5 

Maintenance and service notes

• 

Check that all moving components are functioning 

properly once a year. Check tightness of screwing.

• 

All components of the multi-point lock have alrea

-

dy been treated with long-term lubrication and are 

consequently maintenance-free. However, if a subse

-

quent lubrication should be necessary, use only fully 

synthetic, resin-free spray-on grease.

Содержание KFV

Страница 1: ...OPERATING INSTRUCTIONS KFV Electro mechanical systems Comfort systems Door systems Window systems A opener 2 1 ...

Страница 2: ......

Страница 3: ... Improper use 4 1 5 Maintenance and service notes 4 1 6 Dimensions 5 1 7 Visual indicators 5 1 7 1 Symbols used 5 1 7 2 Other types of indicators 5 1 8 Appropriate disposal 5 1 9 Causes of damage 5 2 SAFETY 7 2 1 Electricity 7 3 THE COMPONENTS OF THE A OPENER 8 3 1 Connector pin assignment 8 4 OPERATION 9 4 1 Menu handling 9 4 2 Set the volume of the buzzer 12 4 3 Call up system services 13 4 4 Di...

Страница 4: ...nfirm Repair of the AS3500 3600 multi point lock with A opener 2 1 is not permissible If the AS3500 3500 multi point lock with A opener 2 1 is damaged it must be replaced by KFV or repaired by a service agent authorised by KFV Only KFV frame parts with Q adjustment may be used 1 3 2 Transport Always transport the door leaf in a vertical position Do not carry the door by the lever handle or hard wa...

Страница 5: ...esponding point 1 7 2 Other types of indicators Below is a list of symbols used in these instructions and their meanings f f Items of text with this marking in front of them are instructions that must be followed in the specified order Items of text following this marker are found in lists Items of text following this marker are found in subordinate lists Items of text in quotation marks are cross...

Страница 6: ...e sash The door leaf must not be carried using the lever hand le as a grip None of the locking elements may be excluded when the door is open Force must be exerted on the lever handle only in the normal direction of rotation A maximum force of 150 N may be applied to the lever handle in the direction of actuation The lock or multi point lock must be locked only with the associated key and not with...

Страница 7: ...AC mains power supply must be carried out in compliance with the current German VDE regulations e g VDE 0100 and any relevant country specific requirements All pole safety isolation should be used when fitting the network connection cable on site Some external access control systems available on the market transmit a brief open signal when the operating voltage is switched on This can mean that th...

Страница 8: ... Terminal C Output supply voltage GND Terminal D Output supply voltage 24 V DC 2 3 Operating voltage Terminal 2 24 V DC Terminal 3 GND 4 External unlocking signal If 24 V DC is supplied to this terminal for 1 sec then an opening cycle is performed 2 Buttons with menu LED All adjustments to the A opener are made via this You can proceed to the individual menus and adjust the different functions by ...

Страница 9: ...ress button 1 sec A Magenta C Black E Red K Turquoise L Blue B White D Orange F Mint H Violet 2 3 4 1 Level 1 2 Level 1 main menu 3 Level 2 adjustment range 4 Legend Button with menu LED The entire operation and all adjustments are perfor med via the button with menu LED Press the button The individual functions are navigated and programmed via the three different holding times 1 sec 3 sec 8 sec T...

Страница 10: ...utton 3 sec Level 3 Adjustment area A D K H Using the example of the menu items System ser vices K In level 3 the LED starts to flash The colour changes between the basic colour of the selected menu item and the colour of the position in the setting range that was saved most recently This is the position of the default settings in case of commissioning The default settings are highlighted in red i...

Страница 11: ...ing You will then proceed automatically to level 1 Ending without changes Wait for timeout 30 s Standby After 2 min without pressing the button with menu LED its light and the status LED light will switch off After an opening signal the latch is retracted and an acoustic signal sounds for up to 3 sec If terminal 4 is continuously activated an acoustic signal is emitted for 7 sec and then automatic...

Страница 12: ...evice A C K C 50 Log output A D K D 25 A E 0 A F Default settings K H Retrieve menu Press button 8 sec Long press Press button 3 sec Short press Press button 1 sec A Magenta C Black E Red K Turquoise L Blue B White D Orange F Mint H Violet 2 1 Level 1 2 Level 1 main menu 3 Level 2 adjustment range 4 Legend A Main menu Press button 1 x 8 sec Save selection Press button 1 x 3 sec A Retrieve adjustme...

Страница 13: ...Press button 1 sec A Magenta C Black E Red K Turquoise L Blue B White D Orange F Mint H Violet 2 3 4 1 Level 1 2 Level 1 main menu 3 Level 2 adjustment range 4 Legend A Main menu Press button 8 sec Save selection Press button 1 x 3 sec K Select menu item System services Press button 1 x 1 sec K Call up menu item System services Press button 1 x 3 sec K B Couple devices only for SI RS485 compatible...

Страница 14: ...lt has been extended via the profile cylinder child proof lock active lever handle blocked LED lights up LED flashes To lock or unlock the door with the cylinder key always turn it as far as it will go The cylinder key must then be turned back some way before it can be removed from the cylinder lock If the door is released automatically it remains open for 3 s and an acoustic signal will be audibl...

Страница 15: ... 40 Electrical data Operating voltage UB 24 V DC 19 V DC to 32 V DC Operating current standby standby IST Type 30 mA Operating current for motor control IB Type 500 mA max 1000 mA Reverse polarity protection UVerp 50 V Input signal terminal 4 Release On UKL4 ON 7 0 V DC Release Off UKL4 OFF 4 0 DC V Internal with Pulldown resistance RPulldown 4 7 kΩ Dimensions Dimensions W x L x D 16 mm x 252 mm x...

Страница 16: ...02 2019 16 18 H47 ELEKS005EN 00 Electromechanical systems Operating instructions A opener 2 1 5 Test report Electromagnetic compatibility ...

Страница 17: ...17 18 02 2019 H47 ELEKS005EN 00 17 18 Operating instructions Electromechanical systems A opener 2 1 ...

Страница 18: ...www siegenia com H47 ELEKS005EN 00 ...

Отзывы: