Fault
Cause and troubleshooting
Remnants of food on
tableware.
Tableware is placed too close together or basket is
overfilled.
1.
Arrange tableware with sufficient space in between.
The spray jets must reach the surfaces of the table-
ware.
2.
Avoid points of contact.
Spray arm rotation of the lower spray arm is blocked.
▶
Arrange tableware so that it does not obstruct
spray arm rotation.
Spray arm nozzles are blocked.
▶
Filters are soiled.
▶
Clean the filters.
→
Filters are inserted incorrectly and/or not engaged.
1.
Insert the filters properly.
→
2.
Engage the filters.
Washing programme selected too weak.
▶
Select a more intensive washing programme.
→
▶
Adjust the sensitivity of the sensors.
→
Tableware has been precleaned too intensely. The
sensors chose a weaker programme. Stubborn soiling
cannot be entirely removed.
▶
Only remove large remnants of food and do not
prerinse tableware.