Siemens HZM Скачать руководство пользователя страница 7

Siemens Industry, Inc.
Building Technologies  Division

P/N 315-034850-8

7

Cyber security disclaimer

Siemens products and solutions provide security functions to ensure the secure operation of
building comfort, fire safety, security management and physical security systems. The security
functions on these products and solutions are important components of a comprehensive security
concept.

It is, however, necessary to implement and maintain a comprehensive, state-of-the-art security
concept that is customized to individual security needs. Such a security concept may result in
additional site-specific preventive action to ensure that the building comfort, fire safety, security
management or physical security system for your site are operated in a secure manner. These
measures may include, but are not limited to, separating networks, physically protecting system
components, user awareness programs, defense in depth, etc

.

For additional information on building technology security and our offerings, contact your Siemens
sales or project department. We strongly recommend customers to follow our security advisories,
which provide information on the latest security threats, patches and other mitigation measures.

 

http://www.siemens.com/cert/en/cert-security-advisories.htm

Содержание HZM

Страница 1: ... Quick Start Manual P N 315 033875 or the FS 250 Programming Manual P N 315 049403 as applicable The alarm verification configuration is used only for non shorting detectors The HZM supports Class A and Class B wiring The module uses one address on the device loop It does not require any mechanical address programming Use the DPU Device Programming Unit to program and test the module HZM HZM FRONT...

Страница 2: ...ows the Class B wiring 1 2 3 4 5 6 7 8 9 EARTH DEVICE LOOP 24VDC POWER LINE 2 LINE 1 STYLE D CLASS A DCLA EOL EOL DEVICE IS 4 7K 1 4W P N 140 820188 FOR CANADIAN APPLICATIONS USE MODEL EL 33 WITH 4 7K 1 4W RESISTOR Figure 2 HZM Initiating Devices Wiring Diagram Class A Style D ULC DCLA Installation Figure 3 HZM Initiating Devices Wiring Diagram Class B Style B ULC DCLB Installation DEVICE LOOP 24V...

Страница 3: ... jumper J1 c Remove the 2 position plug from J1 d Reassemble the circuit board and plastic cover using the screw that was removed in the first step e Be sure to use the correct end of line device with the HZM in this configuration PB 1191 A B C D E F 1 2 3 4 5 6 7 8 9 BEAM DETECTOR WIRING CLASS B STYLE B ULC DCLB HZM J1 EARTH 3 6K 1 4W EOL RESISTOR P N 140 820185 DO NOT CONNECT MORE THAN ONE PB 11...

Страница 4: ... 5 5 6 6 6 6 7 7 7 7 8 8 8 8 9 9 9 9 HZM HZM HZM HZM LINE 2 LINE 1 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6 7 7 7 7 8 8 8 8 9 9 9 9 HZM HZM HZM HZM LINE 2 LINE 1 NOT USED NOT USED NOT USED 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 9 9 9 HZM HZM HZM LINE 2 RETURN LINE 2 OUT LINE 1 OUT LINE 1 RETURN 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 9 9 9 HZM HZM HZM LINE 2 RETURN LINE 2 O...

Страница 5: ...power connection Refer to Figure 7 for the wiring diagram 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 5 5 5 5 5 6 6 6 6 6 7 7 7 7 7 8 8 8 8 8 9 9 9 9 9 HZM HZM HZM HZM HZM CLASS B INSTALLATION T TAPPING ALLOWED TO 24 VDC SEE NOTE 5 Figure 7 HZM 24 VDC Wiring Diagram Mounting 1 Mount the HZM in a standard two gang electrical box The box must have a depth of at least 3 inches 2 When the field wiring for...

Страница 6: ... a t o t s m h o 5 3 e g n a R e g a t l o V y r o s i v r e p u S e v a w l l u f d e r e t l i f C D V 5 4 2 8 1 t n e r r u C e n o Z x a M A m 4 3 r e w o P C D V 4 2 e g n a R e g a t l o V C D V 2 8 2 8 8 1 t n e r r u C x a M A m 0 0 1 t n e r r u C y b d n a t S A m 6 6 p o o L C L D S F C L D t n e r r u C x a M A m 1 ELECTRICAL RATINGS ...

Страница 7: ...needs Such a security concept may result in additional site specific preventive action to ensure that the building comfort fire safety security management or physical security system for your site are operated in a secure manner These measures may include but are not limited to separating networks physically protecting system components user awareness programs defense in depth etc For additional i...

Страница 8: ...y Inc Building Technologies Division Florham Park NJ Siemens Canada Ltd 1577 North Service Road East Oakville Ontario L6H 0H6 Canada P N 315 034850 8 This page has been left intentionally blank Document ID A6V10233195 ...