Parameter reference
8.6 Setup (2.)
HydroRanger 200 HMI
Operating Instructions, 06/2018, A5E36281317-AC
175
8.6.3.5
Rate filter (2.3.5.)
Damps the Flow Maximum (3.2.8.15.) (Page 259) fluctuations
Index
Single-point model
Dual-point model
Global
Transducer
Options
Rate display not required
Filtered Output: Continuous filtering and update
Interval Output:
*1 min or 50 mm (2 in)
5 min or 100 mm (3.9 in)
10 min or 300 mm (11.8 in)
10 min or 1000 mm (39.4 in)
Alters
Flow Maximum (3.2.8.15.) (Page 259)
Altered by
Response Rate (2.3.4.) (Page 174)
Related
Rate Filter Time (2.3.6.) (Page 175)
Rate Filter Distance (2.3.7.) (Page 175)
Enter the time or distance interval over which the Flow Maximum (3.2.8.15.) (Page 259) is to
be calculated before the display updates.
This is automatically altered along with Response Rate (2.3.4.) (Page 174).
This value automatically alters the Rate Filter Time (2.3.6.) (Page 175) and/or Rate Filter
Distance (2.3.7.) (Page 175). Alternatively, these parameter values may be altered
independently.
8.6.3.6
Rate filter time (2.3.6.)
The time period, in seconds, over which the material level rate of change is averaged before
Flow Maximum (3.2.8.15.) (Page 259) updates.
Index
Single-point model
Dual-point model
Global
Transducer
Values
Range: 0.000 ... 9999 seconds
Related
Flow Maximum (3.2.8.15.) (Page 259)
8.6.3.7
Rate filter distance (2.3.7.)
The material level change, in meters, to initiate a Flow Maximum (3.2.8.15.) (Page 259)
update.
Index
Single-point model
Dual-point model
Global
Transducer
Values
Range: 0.000 ... 9999 meters
Related
Flow Maximum (3.2.8.15.) (Page 259)
Содержание HydroRanger 200 HMI
Страница 2: ......
Страница 20: ...Introduction 1 5 Notes on warranty HydroRanger 200 HMI 18 Operating Instructions 06 2018 A5E36281317 AC ...
Страница 24: ...Safety notes HydroRanger 200 HMI 22 Operating Instructions 06 2018 A5E36281317 AC ...
Страница 28: ...Description 3 5 Modbus communication HydroRanger 200 HMI 26 Operating Instructions 06 2018 A5E36281317 AC ...
Страница 159: ...Parameter reference 8 2 Parameter indexing HydroRanger 200 HMI Operating Instructions 06 2018 A5E36281317 AC 157 ...
Страница 276: ...Parameter reference 8 10 Language 6 HydroRanger 200 HMI 274 Operating Instructions 06 2018 A5E36281317 AC ...
Страница 322: ...Pump control reference B 13 Other pump controls HydroRanger 200 HMI 320 Operating Instructions 06 2018 A5E36281317 AC ...
Страница 352: ...Communications C 41 Single parameter access SPA HydroRanger 200 HMI 350 Operating Instructions 06 2018 A5E36281317 AC ...
Страница 354: ...Updating software HydroRanger 200 HMI 352 Operating Instructions 06 2018 A5E36281317 AC ...
Страница 359: ...HydroRanger 200 HMI Operating Instructions 06 2018 A5E36281317 AC 357 Conduit entry for Class I Div 2 applications F ...
Страница 360: ...Conduit entry for Class I Div 2 applications HydroRanger 200 HMI 358 Operating Instructions 06 2018 A5E36281317 AC ...
Страница 361: ...Conduit entry for Class I Div 2 applications HydroRanger 200 HMI Operating Instructions 06 2018 A5E36281317 AC 359 ...
Страница 362: ......
Страница 372: ...Programming chart G 1 Programming chart HydroRanger 200 HMI 370 Operating Instructions 06 2018 A5E36281317 AC ...
Страница 390: ...LCD menu structure H 1 LCD Menu Structure HydroRanger 200 HMI 388 Operating Instructions 06 2018 A5E36281317 AC ...
Страница 403: ......