Installing HiPath 3000
Installing HiPath 3800
AC Outlet Requirements
●
A UL-listed or CSA-certified surge protector must be connected between the socket and
the system. Two cabinets can be connected to each surge protector. Never connect a Hi-
Path 3800 system or a combination of systems directly to a wall socket.
●
The power source may not be more than 2.4 m (8 ft.) from the system.
●
The power source must provide 120 V AC (single-phase, fused) power at 50-60 Hz and 20
A.
●
A warning should be attached to the circuit breaker to prevent accidental removal of power.
●
An independent electric circuit with an isolated ground conductor should be used.
The system must be properly grounded before startup (see description in Section 4.1.3.4).
Table 4-2
Electrical Connection Values (for U.S. only)
Nominal
voltage
Nominal voltage range
Nominal Frequency
Range
Wall Outlet Configura-
tions
from
to
from to
120 V AC/
60 Hz
110 V AC
130 V AC
47 Hz
63 Hz
NEMA 5-15, 2-pin, 3-
wire, earth
7
WARNING
Never connect a HiPath 3800 system or a combination of HiPath 3800 systems di-
rectly to a wall socket. Use a UL-listed or CSA-certified surge protector for every two
cabinets.