Installation and connection
en
9
Positioning and levelling
Positioning the appliance
When installing the appliance, make sure that there is
enough space in the final installation location to pull the
appliance forwards for cleaning and maintenance work.
The ground underneath must be hard and firm. The wall
immediately behind the appliance must be made from
non-flammable material, e.g. tiles.
If you need to move the appliance in order to position it,
make sure that the adjustable feet are fully screwed in.
Aligning the appliance
Turn the adjustable feet to align the appliance.
Note:
Do not align the appliance until all other work has
been completed.
The adjustable feet can be used to elevate the
appliance by a maximum of 50 mm.
Check the alignment of the appliance once it has been
installed in the intended place.
Adjacent units
Any adjacent units must not be made of flammable
materials. The fronts of any adjacent units must be heat-
resistant up to at least 90 °C. If the appliance is
installed very close to any other units, the minimum
clearances given in the figure must be maintained.
Wall fixing
To prevent the cooker from tipping over, you must fix it
to the wall using the enclosed bracket. Please observe
the installation instructions for fixing the oven to the
wall.
Gas connection
Installation must only be performed by an approved
expert or a licensed after-sales service engineer in
accordance with the instructions specified under "Gas
connection and conversion to a different gas type".
For the licensed expert or after-sales service
Caution!
■
The settings for configuring this appliance can be
found on the rating plate.
■
Before setting up the appliance, check the grid
access conditions (gas type and gas pressure) and
ensure that the gas setting of the appliance meets
these conditions. If the appliance settings have to be
changed, follow the instructions in the section "Gas
connection and conversion to a different gas type".
■
This appliance is not connected to a waste gas
main. It must be connected and commissioned in
accordance with the installation conditions. Do not
connect the appliance to a waste gas main. All
ventilation regulations must be observed.
■
The gas connection must be made via a fixed, i.e.
not mobile connection (gas line) or via a safety
hose.
■
If using the safety hose, ensure that the hose is not
trapped or crushed. The hose must not come into
contact with hot surfaces.
■
The connection must have an easily accessible
locking device.
Flexible hoses
For flexible hoses, observe the following points:
■
Do not pinch or squeeze hoses.
■
Do not subject the hoses to twisting or pulling
forces.
■
Keep the hoses away from sharp edges.
■
Do not let the hoses come into contact with parts
that may reach a temperature higher than 70 °C
above room temperature.
■
Make sure that the full length of the hoses is
accessible for inspection.
Checking for leaks
After connecting the gas line, check the connections for
leaks using soapy water.
Initial use
Switch the appliance on as described in the instructions
for use. Light all the burners and check that the flames
remain stable at both the high and low settings.
Faults in the gas installation/smell of gas
If you notice a smell of gas or faults in the gas
installation, you must
■
immediately shut off the gas supply and/or close the
gas cylinder valve
■
immediately extinguish all naked flames and
cigarettes
■
switch off electrical appliances and lights
■
open windows and ventilate the room
■
call the after
sales service or the gas supplier
PLQ
PLQ
PLQ
PLQ
PLQ