22.2 Appliance dimensions
You will find the dimensions of the appliance here
22.3 Installation below a worktop
Observe the installation dimensions and the installation
instructions when installing below a worktop.
¡
To ventilate the appliance, the intermediate floor
must have a ventilation cut-out.
¡
In combination with induction hobs, the gap
between the worktop and appliance must not be
sealed using additional strips.
¡
The worktop must be secured to the built-in unit.
¡
Observe any available installation instructions for the
hob.
22.4 Installation in a tall unit
Observe the installation dimensions and the installation
instructions when installing in a tall unit.
¡
To ventilate the appliance, the intermediate floors
must have a ventilation cut-out.
¡
If the tall unit has another back panel in addition to
the element back panels, this must be removed.
¡
Only fit the appliance up to a height which allows
accessories to be easily removed.
22.5 Installing two appliances on top of
each other
Your appliance can also be installed above or below
another appliance. Observe the installation dimensions
and the installation instructions when installing appli-
ances on top of each other.
¡
To ventilate the appliances, the intermediate floor
must have a ventilation cut-out.
¡
To ensure sufficient ventilation of the two appli-
ances, there must be a ventilation opening of at
least 200 cm² in the base area. To do this, trim the
base panel or fit a ventilation grille.
¡
Ensure that air exchange is guaranteed in accord-
ance with the diagram.
¡
Only fit appliances up to a height that allows ac-
cessories to be easily removed.