Siemens Home and Office Communication Devices GmbH & Co. KG
Confidential
7
SHC CC RCT
Version 1.5
J. Junggebauer
X / Y
Action
Options / description
3 / -
PIN Reset
Set only system Pin to default (0000)
4 / 1
Write to EEPROM address
coded string consists of 15
bytes and holds checksum,
mask, data, offset and segment
4 / 2
Version display
Sample display:
"0103200 00000"
12-digit
Meaning:
Variante 2-digit “01”
Version 3-digit "032"
Revision 2-digit "00"
space
User ID 3-digit "000"
Localincrement “00”
All decimal
4 / 3
Ring detection frequency
0 = 20-60 Hz
1 = 15-75 Hz
2 = other factory setting
4 / 4
DP behaviour pulse pause
0 = 1.5 : 1
1 = 2 : 1
4 / 5
CLIP list activated
0 = on
1 = off
4 / 6
Off-hook CLIP activated
0 = off
1 = on
6 / 2
Exception Place and Code
6 / 5
Approval test
will stay activated until
power on reset
Read out RFPI, working time counter of base station, SW version of base station:
Precondition: Line seized, number dialled out, connection is set up for at least 8 seconds
1. RFPI of base station
2. IPUI of current handset
3. Working time counter
4. SW version of base station